Machine Learning approach for TWA detection relying on ensemble data design

被引:3
作者
Fernandez-Calvillo, Miriam Gutierrez [1 ]
Goya-Esteban, Rebeca [2 ]
Cruz-Roldan, Fernando [1 ]
Hernandez-Madrid, Antonio [3 ]
Blanco-Velasco, Manuel [1 ]
机构
[1] Univ Alcala, Dept Teoria Senal & Comunicac, Madrid, Spain
[2] Univ Rey Juan Carlos, Dept Teoria Senal & Comunicac, Madrid, Spain
[3] Univ Alcala, Ramon & Cajal Hosp, Arrhythmia Unit, Madrid, Spain
关键词
Machine Learning (ML); Spectral Method (SM); Modified Moving Average Method (MMA); Time Method (TM); Cross Validation (CV); Repolarization; T-Wave Alternans (TWA); Electrocardiogram (ECG); T-WAVE-ALTERNANS; MOVING AVERAGE ANALYSIS; ELECTRICAL ALTERNANS; RISK STRATIFICATION; ELECTROCARDIOGRAM; VULNERABILITY; TRACKING;
D O I
10.1016/j.heliyon.2023.e12947
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background and objective: T-wave alternans (TWA) is a fluctuation of the ST-T complex of the surface electrocardiogram (ECG) on an every-other-beat basis. It has been shown to be clinically helpful for sudden cardiac death stratification, though the lack of a gold standard to benchmark detection methods limits its application and impairs the development of alternative techniques. In this work, a novel approach based on machine learning for TWA detection is proposed. Additionally, a complete experimental setup is presented for TWA detection methods benchmarking. Methods: The proposed experimental setup is based on the use of open-source databases to enable experiment replication and the use of real ECG signals with added TWA episodes. Also, intra-patient overfitting and class imbalance have been carefully avoided. The Spectral Method (SM), the Modified Moving Average Method (MMA), and the Time Domain Method (TM) are used to obtain input features to the Machine Learning (ML) algorithms, namely, K Nearest Neighbor, Decision Trees, Random Forest, Support Vector Machine and Multi-Layer Perceptron. Results: There were not found large differences in the performance of the different ML algorithms. Decision Trees showed the best overall performance (accuracy 0.88 +/- 0.04, precision 0.89 +/- 0.05, Recall 0.90 +/- 0.05, F1 score 0.89 +/- 0.03). Compared to the SM (accuracy 0.79, precision 0.93, Recall 0.64, F1 score 0.76) there was an improvement in every metric except for the precision. Conclusions: In this work, a realistic database to test the presence of TWA using ML algorithms was assembled. The ML algorithms overall outperformed the SM used as a gold standard. Learning from data to identify alternans elicits a substantial detection growth at the expense of a small increment of the false alarm.
引用
收藏
页数:13
相关论文
共 54 条
[1]   An active learning method for diabetic retinopathy classification with uncertainty quantification [J].
Ahsan, Muhammad Ahtazaz ;
Qayyum, Adnan ;
Razi, Adeel ;
Qadir, Junaid .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2022, 60 (10) :2797-2811
[2]   A template matched-filter based scheme for detection and estimation of t-wave alternans [J].
Bashir, Sajid ;
Bakhshi, Asim Dilawer ;
Maud, Mohammad Ali .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2014, 13 :247-261
[3]  
Bishop Christopher M., 2006, Pattern recognition and machine learning, DOI [10.1007/978-0-387-45528-0, DOI 10.1007/978-0-387-45528-0]
[4]   Benchmarking of a T-wave alternans detection method based on empirical mode decomposition [J].
Blanco-Velasco, Manuel ;
Goya-Esteban, Rebeca ;
Cruz-Roldan, Fernando ;
Garcia-Alberola, Arcadi ;
Rojo-Alvarez, Jose Luis .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2017, 145 :147-155
[5]   Nonlinear Trend Estimation of the Ventricular Repolarization Segment for T-Wave Alternans Detection [J].
Blanco-Velasco, Manuel ;
Cruz-Roldan, Fernando ;
Ignacio Godino-Llorente, Juan ;
Barner, Kenneth E. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (10) :2402-2412
[6]  
Burattini L., 1999, Annals of Noninvasive Electrocardiology, V4, P416, DOI 10.1111/j.1542-474X.1999.tb00232.x
[7]   Adaptive match filter based method for time vs. amplitude characterization of microvolt ECG T-wave alternans [J].
Burattini, Laura ;
Zareba, Wojciech ;
Burattini, Roberto .
ANNALS OF BIOMEDICAL ENGINEERING, 2008, 36 (09) :1558-1564
[8]   Correlation method versus enhanced modified moving average method for automatic detection of T-wave alternans [J].
Burattini, Laura ;
Bini, Silvia ;
Burattini, Roberto .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2010, 98 (01) :94-102
[9]   Comparative analysis of methods for automatic detection and quantification of microvolt T-wave alternans [J].
Burattini, Laura ;
Bini, Silvia ;
Burattini, Roberto .
MEDICAL ENGINEERING & PHYSICS, 2009, 31 (10) :1290-1298
[10]   Enhanced modified moving average analysis of T-wave alternans using a curve matching method: a simulation study [J].
Cuesta-Frau, D. ;
Mico-Tormos, Pau ;
Aboy, M. ;
Biagetti, Marcelo O. ;
Austin, D. ;
Quinteiro, Ricardo A. .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2009, 47 (03) :323-331