A simple and rapid HPLC-MS/MS method for therapeutic drug monitoring of amikacin in dried matrix spots

被引:2
|
作者
Chen, Yan [1 ]
Wang, Yu [1 ]
Guo, Beining [1 ]
Fan, Yaxin [1 ]
Wu, Hailan [1 ]
Li, Xin [1 ]
Li, Yi [1 ]
Huang, Xiaolan [1 ]
Chen, Mengting [1 ]
Liu, Xiaofen [1 ,2 ]
Zhang, Jing [1 ,2 ]
机构
[1] Fudan Univ, Huashan Hosp, Inst Antibiot, Key Lab Clin Pharmacol Antibiot,Natl Clin Res Ctr, Shanghai 200040, Peoples R China
[2] 12 Wulumuqi Zhong Rd, Shanghai 200040, Peoples R China
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2023年 / 1220卷
关键词
Amikacin; Therapeutic drug monitoring; Serum; Dried matrix spot; HPLC-MS; MS; QUANTITATIVE-ANALYSIS; LC-MS/MS; INFECTIONS; PLASMA; QUANTIFICATION; VALIDATION;
D O I
10.1016/j.jchromb.2023.123592
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Individualized treatment of amikacin under the guidance of therapeutic drug monitoring (TDM) is important to reduce the occurrence of toxicity and improve clinical efficacy. In the present study, we developed and validated a simple and high-throughput liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to determine the concentration of amikacin in dried matrix spots (DMS) which the matrix is serum. DMS samples were obtained by spotting volumetric blood onto Whatman 903 (R) cards. Samples were punched into 3 mm diameter discs and extracted with 0.2 % formic acid in water. The HILIC column (2.1 mm x 100 mm, 3.0 mu m) under gradient elution was applied, and the analysis time was 3 min per injection. The mass spectrometry transitions were m/z 586.3-* 163.0 for amikacin and m/z 591.4-* 163.1 for D5-amikacin. Full validation was conducted for DMS method, and the method was applied for the amikacin TDM and compared with serum method. The linearity was ranged from 0.5 to 100 mg/L. Both within-run and between-run accuracy and pre-cision of DMS ranged from 91.8 % to 109.6 % and 3.6 % to 14.2 %, respectively. The matrix effect was 100.5 %- 106.5 % of DMS method. Amikacin remained stable in DMS for at least 6 days at room temperature, 16 days at 4 degrees C, 86 days at-20 degrees C and-70 degrees C. A good agreement between the DMS method and serum method has been shown in Bland-Altman plots and Passing-Bablok regression. All of the results demonstrated that the DMS methods can be a favorable replacement for amikacin TDM.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] A sensitive and rapid ultra HPLC-MS/MS method for the simultaneous detection of clopidogrel and its derivatized active thiol metabolite in human plasma
    Peer, Cody J.
    Spencer, Shawn D.
    VanDenBerg, Dustin A. H.
    Pacanowski, Michael A.
    Horenstein, Richard B.
    Figg, William D.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 880 : 132 - 139
  • [32] A Validated LC-MS/MS Method for the Determination of Mezlocillin in Plasma: An Adapted Method for Therapeutic Drug Monitoring in Children
    Tang, Bo-Hao
    Kan, Min
    Yang, Xin-Mei
    Wang, Rong-Hua
    Shi, Hai-Yan
    Zheng, Yi
    Hao, Guo-Xiang
    Song, Lin-Lin
    Zhao, Wei
    CURRENT PHARMACEUTICAL ANALYSIS, 2021, 17 (07) : 853 - 860
  • [33] A rapid and sensitive HPLC-MS method for the detection of plasma and cellular rifampicin
    Hartkoorn, Ruben C.
    Khoo, Saye
    Back, David J.
    Tjia, John F.
    Waitt, Catriona J.
    Chaponda, Masautso
    Davies, Geraint
    Ardrey, Alison
    Ashleigh, Samantha
    Ward, Stephen A.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 857 (01): : 76 - 82
  • [34] Development and validation of a simple HPLC-MS/MS method for the quantification of methylmalonic acid in human serum without a derivatization step
    Hofmann, Sabrina
    Gebauer, Julian
    Krnac, Dusan
    Prantz, Anja
    Reiffova, Katarina
    Rolinski, Boris
    Serbin, Rastislav
    BIOMEDICAL CHROMATOGRAPHY, 2023, 37 (08)
  • [35] Evaluating the Degradation Process of Collagen Sponge and Acellular Matrix Implants In Vivo Using the Standardized HPLC-MS/MS Method
    Gao, Jianping
    Ma, Ye
    Guo, Zhenhu
    Zhang, Yang
    Xing, Fangyu
    Zhang, Tianyang
    Kong, Yingjun
    Luo, Xi
    Xu, Liming
    Zhang, Guifeng
    SEPARATIONS, 2023, 10 (01)
  • [36] Simultaneous Determination of Dabigatran, Rivaroxaban, Apixaban, and Warfarin in Human Blood Serum by HPLC-MS/MS for Therapeutic Drug Monitoring
    T. A. Rodina
    E. S. Melnikov
    A. A. Aksenov
    S. A. Belkov
    A. V. Sokolov
    A. B. Prokof’ev
    G. V. Ramenskaya
    Pharmaceutical Chemistry Journal, 2022, 56 : 289 - 293
  • [37] Development and validation of an HPLC-MS/MS method for the analysis of dexamethasone from pig synovial fluid using dried matrix spotting
    Christianson, Chad D.
    Laine, Derek F.
    Zimmer, Jennifer S. D.
    Johnson, Casey J. L.
    Sheaff, Chrystal N.
    Carpenter, Anna
    Needham, Shane R.
    BIOANALYSIS, 2010, 2 (11) : 1829 - 1837
  • [38] Rapid and simple LC-MS/MS screening of 64 novel psychoactive substances using dried blood spots
    Ambach, Lars
    Redondo, Ana Hernandez
    Koenig, Stefan
    Weinmann, Wolfgang
    DRUG TESTING AND ANALYSIS, 2014, 6 (04) : 367 - 375
  • [39] A Rapid and Simple HPLC Method for Therapeutic Monitoring of Vancomycin
    Lima, Tacio de Mendonca
    Seba, Karine Souza
    Saraiva Goncalves, Jose Carlos
    Lopes Cardoso, Fernando Luiz
    Elias Estrela, Rita de Cassia
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2018, 56 (02) : 115 - 121
  • [40] A rapid and reliable method for the quantitation of tricyclic antidepressants in serum using HPLC-MS/MS
    Breaud, Autumn R.
    Harlan, Robert
    Kozak, Marta
    Clarke, William
    CLINICAL BIOCHEMISTRY, 2009, 42 (12) : 1300 - 1307