Rapid Sampling and Determination of Low Molecular Weight Polycyclic Aromatic Hydrocarbons (PAHs) in Air by a Needle Trap Device Coupled with Gas Chromatography-Mass Spectrometry (GC-MS)

被引:1
|
作者
Duan, Yingming [1 ]
Ao, Ya [1 ]
Huang, Liling [1 ]
Dong, Xian [1 ]
Liang, Longchao [1 ]
Liu, Shuqin [2 ]
Chen, Zhuo [1 ,3 ]
机构
[1] Guizhou Normal Univ, Sch Chem & Mat Sci, Guiyang, Peoples R China
[2] Guangdong Acad Sci, China Natl Analyt Ctr Guangzhou, Inst Anal, Guangdong Prov Engn Res Ctr Ambient Mass Spectrome, Guangzhou, Peoples R China
[3] Guizhou Normal Univ, Sch Chem & Mat Sci, Guiyang 550001, Guizhou, Peoples R China
基金
中国国家自然科学基金;
关键词
Environmental air analysis; gas chromatography-mass spectrometry (GC-MS); low molecular weight polycyclic aromatic hydrocarbons (LPAHs); needle trap device; on-site sampling; POLYAROMATIC HYDROCARBONS;
D O I
10.1080/00032719.2023.2184477
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Low molecular weight polycyclic aromatic hydrocarbons (LPAHs) are widely present in the environment which poses a serious threat to human health. However, current preprocessing methods in detection are complicated. In this study, a method for rapid sampling and determination of LPAHs in the air was established using a needle trap device coupled with gas chromatography-mass spectrometry. The experimental parameters for NTD-GC-MS were optimized. This method has a linear calibration range from 10 to 1000 ng/L with correlation coefficients (R-2) >= 0.990. The limits of detection and limits of quantification were from 0.40 to 0.55 ng/L and 1.33 to 1.82 ng/L, respectively. The recoveries were between 85.63% and 106.6%, and the relative standard deviations were below 12.34%. The method was applied to the determination of LPAHs in a smoking room and an auto-shop paint booth. In the former, the only detected LPAH was naphthalene, for which the highest concentration in a day was 471.4 +/- 102.1 ng/L. In the paint booth, the highest concentrations of acenaphthene and fluorene were 203.5 +/- 32.15 and 184.0 +/- 29.64 ng/L, respectively. The results are meaningful for the occupationally exposed population and those suffering from secondhand smoke. The results show that NTD provides a fast and accurate sampling technology for volatile organic compounds from gases.
引用
收藏
页码:2764 / 2776
页数:13
相关论文
共 50 条
  • [41] Determination of airborne polycyclic aromatic hydrocarbons at an airport by gas chromatography-mass spectrometry and evaluation of occupational exposure
    Iavicoli, Ivo
    Chiarotti, Marcello
    Bergamaschi, Antonio
    Marsili, Remo
    Carelli, Giovanni
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1150 (1-2) : 226 - 235
  • [42] Isotope dilution determination of polycyclic aromatic hydrocarbons in olive pomace oil by gas chromatography-mass spectrometry
    Diletti, G
    Scortichini, G
    Scarpone, R
    Gatti, G
    Torreti, L
    Migliorati, G
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1062 (02) : 247 - 254
  • [43] Determination of particulate polycyclic aromatic hydrocarbons in ambient air by gas chromatography-mass spectrometry after molecularly imprinted polymer extraction
    Pietrogrande, Maria Chiara
    Demaria, Giorgia
    Russo, Mara
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2023, 124 : 644 - 654
  • [44] Determination of particulate polycyclic aromatic hydrocarbons in ambient air by gas chromatography-mass spectrometry after molecularly imprinted polymer extraction
    Maria Chiara Pietrogrande
    Giorgia Demaria
    Mara Russo
    Journal of Environmental Sciences, 2023, 124 (02) : 644 - 654
  • [45] Quantification of Higher Molecular Weight Polycyclic Aromatic Hydrocarbons in Water Samples by Modified Magnetic Nanoparticle and Gas Chromatography-Mass Spectrometry
    Alfarhani, Bassam F.
    Hammza, Rana A.
    Zadeh, E. H. Ghazvini
    CHEMISTRY AFRICA-A JOURNAL OF THE TUNISIAN CHEMICAL SOCIETY, 2022, 5 (06): : 2185 - 2191
  • [46] Quantitative determination of wine polysaccharides by gas chromatography-mass spectrometry (GC-MS) and size exclusion chromatography (SEC)
    Guadalupe, Zenaida
    Martinez-Pinilla, Olga
    Garrido, Alvaro
    David Carrillo, Jose
    Ayestaran, Belen
    FOOD CHEMISTRY, 2012, 131 (01) : 367 - 374
  • [47] Isolation of Volatiles in Honeysuckle by Multiple Approaches with Determination by Gas Chromatography-Mass Spectrometry (GC-MS) and Headspace Solid-Phase Microextraction-Gas Chromatography-Mass Spectrometry (HS-SPME/GC-MS)
    Ni, Lijun
    Lu, Qingmei
    Hou, Huanyao
    Zhang, Liguo
    Luan, Shaorong
    ANALYTICAL LETTERS, 2023, 56 (14) : 2359 - 2370
  • [48] Quantitative determination of polycyclic aromatic hydrocarbons in barbecued meat sausages by gas chromatography coupled to mass spectrometry
    Mottier, P
    Parisod, V
    Turesky, RJ
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2000, 48 (04) : 1160 - 1166
  • [49] Determination of polycyclic aromatic hydrocarbons in lipstick by gas-chromatography coupled to mass spectrometry: A case history
    Roda, Gabriella
    Arnoldi, Sebastiano
    Casagni, Eleonora
    Dei Cas, Michele
    Silva, Laura
    Carini, Marina
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 165 : 386 - 392
  • [50] Determination of aromatic and polycyclic aromatic hydrocarbons in gasoline using programmed temperature vaporization-gas chromatography-mass spectrometry
    Perez Pavon, Jose Luis
    Sanchez, Miguel del Nogal
    Fernandez Laespada, Maria Esther
    Cordero, Bernardo Moreno
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1202 (02) : 196 - 202