Experimental Study on Seismic Performance of Prefabricated Monolithic Concrete-Polystyrene Panel Composite Wall Panels

被引:2
作者
Zhao, Kaozhong [1 ,2 ]
Fan, Zijia [1 ,3 ]
Zhang, Yuming [1 ]
Xu, Yufeng [1 ,3 ]
Liu, Sihong [1 ]
机构
[1] Shandong Jianzhu Univ, Sch Civil Engn, Jinan 250101, Peoples R China
[2] Shandong Jianzhu Univ, Key Lab Bldg Struct Retrofitting & Underground Spa, Minist Educ, Jinan 250101, Peoples R China
[3] Shandong Jianzhu Univ Co Ltd, Engn Res Inst Appraisal & Strengthening, Jinan, Peoples R China
关键词
prefabricated monolithic; reinforced concrete; composite wall panels; seismic performance; quasi-static test; CARBON NANOTUBES; VIBRATION; BEHAVIOR;
D O I
10.3390/buildings14020442
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A normal composite wall panel is a structural component composed of polystyrene insulation boards and concrete surface layers reinforced with steel wire mesh. It can be entirely prefabricated in a factory or constructed with the concrete surface layers cast on-site. A novel prefabricated monolithic concrete-polystyrene panel composite wall panel (CPC wall panel) is proposed in this study. The CPC panel features a middle part that is prefabricated in the factory while the reinforced concrete regions at its two side ends are cast on-site. To evaluate the seismic performance of the wall panel, 18 CPC specimens were designed, manufactured, and quasi-statically tested, through which the structural behaviors, failure mode, and load-bearing capacity were studied. In addition, the influences of the height-to-width ratio and the vertical compressive stress level on the seismic performance of the CPC panels were also investigated. The test results showed that the connectors spaced at 400 mm x 500 mm could ensure the concrete layers on both sides of the polystyrene board worked collectively under seismic conditions. When subjected to lateral loads, the interface between the newly poured concrete and the existing concrete exhibited good bonding. Moreover, the failure mode of the CPC wall panel was largely correlated to the height-to-width ratio that, for specimens having four steel bars of 12 mm diameter and a height-to-width ratio greater than 1, the flexural failure was initially developed, followed by diagonal shear failure. In specimens with a height-to-width ratio of 1, flexural and diagonal shear failures occurred almost simultaneously. For specimens with a height-to-width ratio of less than 1, the final diagonal shear failure was predominant. The longitudinal reinforcing bars at the two ends of the CPC panels could effectively improve their lateral load-bearing capacity, with the enhancement influenced by the height-to-width ratio, the vertical load applied to the wall panel, and the cross-sectional area of the steel bars. In practice, the lateral load-bearing capacity of the CPC panel can be conservatively evaluated using the calculation method of the reinforced concrete shear walls. Finally, the ductility of the CPC specimens was affected by the height-to-width ratio and the axial compressive stress level, such that the specimens with a larger height-to-width ratio and lower axial compressive stress exhibited better ductility.
引用
收藏
页数:17
相关论文
共 29 条
[1]   Structural behavior of axially loaded precast foamed concrete sandwich panels [J].
Amran, Y. H. Mugahed ;
Ali, A. A. Abang ;
Rashid, Raizal S. M. ;
Hejazi, Farzad ;
Safiee, Nor Azizi .
CONSTRUCTION AND BUILDING MATERIALS, 2016, 107 :307-320
[2]  
[Anonymous], 2010, JGJ 3-2010
[3]   Nonlinear vibration of a shear deformable functionally graded plate [J].
Chen, CS .
COMPOSITE STRUCTURES, 2005, 68 (03) :295-302
[4]   Effects of grid-type shear connector arrangements used for insulated concrete sandwich wall panels with a low aspect ratio [J].
Choi, Insub ;
Kim, JunHee ;
Kim, DongWon ;
Park, JongSoo .
JOURNAL OF BUILDING ENGINEERING, 2022, 46
[5]   Experimental study on seismic behaviour of an unreinforced precast wall-slab structure based on UHPC sandwich panels [J].
Ding, Ran ;
Sun, Yong-Tao ;
Nie, Xin ;
Chen, Ding-Qiu .
JOURNAL OF BUILDING ENGINEERING, 2023, 68
[6]   Structural feasibility of Expanded Polystyrene (EPS) based lightweight concrete sandwich wall panels [J].
Fernando, P. L. N. ;
Jayasinghe, M. T. R. ;
Jayasinghe, C. .
CONSTRUCTION AND BUILDING MATERIALS, 2017, 139 :45-51
[7]   Test and analysis on axial performances of GFRP restraint connectors for sandwich insulation wall panels [J].
He, Zhi-Zhou ;
Pan, Peng ;
Xiao, Gen-Qi ;
Shen, Shao-Dong ;
Ren, Jun-Yu .
JOURNAL OF BUILDING ENGINEERING, 2022, 45
[8]   Flexural performance of precast geopolymer concrete sandwich panel enabled by FRP connector [J].
Huang, Jun-Qi ;
Dai, Jian-Guo .
COMPOSITE STRUCTURES, 2020, 248
[9]   Nonlocal vibrations and potential instability of monolayers from double-walled carbon nanotubes subjected to temperature gradients [J].
Kiani, Keivan ;
Pakdaman, Hossein .
INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2018, 144 :576-599
[10]   Free vibration of in-plane-aligned membranes of single-walled carbon nanotubes in the presence of in-plane-unidirectional magnetic fields [J].
Kiani, Keivan .
JOURNAL OF VIBRATION AND CONTROL, 2016, 22 (17) :3736-3766