A plastic-based model for in-plane shear strength of steel plate-concrete shear walls

被引:3
作者
Wang, Xingchao [1 ]
Gong, Jinxin [1 ]
Sun, Yunlun [2 ]
机构
[1] Dalian Univ Technol, Inst Struct Engn, Dalian 116024, Peoples R China
[2] Chinergy Co Ltd, Beijing 100193, Peoples R China
关键词
Nuclear facility; Steel plate-concrete shear wall; In-plane shear strength; Plastic limit theory; Lower bound solution; COMPOSITE; DESIGN;
D O I
10.1016/j.jcsr.2022.107676
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The steel plate-concrete shear wall (SCSW) has great potential being used in nuclear facilities due to its high construction efficiency and excellent structural performance. Although it is not new, but only thirty-year history of study for application in nuclear facilities. Different from other ordinary structures, nuclear facilities are low-rise buildings consisting of squat shear walls, and the in-plane, out-of-plane shear capacity and their combination are of concern in design. Currently, several equations for evaluation of in-plane shear strength of SCSW element are put forward and some are adopted by design codes with some modification. However, these equations are established based on the elastic theory and do not consider the collaborative work of infilled concrete and steel plates in limit state from an overall perspective. From the ultimate limit design point of view in current design structural codes or standards, a new model for evaluating the in-plane shear strength of the SCSW element is derived based on the lower bound plastic limit theory and two of its simplified expressions are proposed for easy application. The accuracy of the proposed equations is verified by comparing the calculated results with 14 collected experimental results. In the end, a comparison between the proposed equations and those in codes AISC N690 and JEAG 4618 is conducted.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Behavior prediction of corrugated steel plate shear walls with openings
    Farzampour, Alireza
    Laman, Jeffrey A.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 114 : 258 - 268
  • [42] Analysis of Thin Steel Plate Shear Walls Using the Three-Strip Model
    Tian, Weifeng
    Hao, Jiping
    Fan, Chunlei
    JOURNAL OF STRUCTURAL ENGINEERING, 2016, 142 (05)
  • [43] Strip model for steel plate shear walls with beam-connected web plates
    Ozcelik, Yigit
    Clayton, Patricia M.
    ENGINEERING STRUCTURES, 2017, 136 : 369 - 379
  • [44] In-Plane Deformation of Stiffeners Around Opening in Steel Shear Panels
    Sabouri-Ghomi, Saeid
    Ahouri, Elnaz
    Bhowmick, Anjan K.
    Asad-Sajjadi, Ramin
    Sabouri-Ghomi, Mohammad
    INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 2022, 20 (06) : 661 - 689
  • [45] Stiffness and Strength Of Perforated Steel Plate Shear Wall
    Chan, Ricky
    Albermani, Faris
    Kitipornchai, S.
    PROCEEDINGS OF THE TWELFTH EAST ASIA-PACIFIC CONFERENCE ON STRUCTURAL ENGINEERING AND CONSTRUCTION (EASEC12), 2011, 14
  • [46] Stress state of steel plate shear walls under compression-shear combination load
    Lv, Yang
    Wu, Di
    Zhu, Yuhao
    Liang, Xiao
    Shi, Yanchao
    Yang, Zhen
    Li, Zhong-Xian
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2018, 27 (06)
  • [47] Seismic behavior of steel fiber reinforced high strength concrete shear walls with different embedded steel configurations
    Li, Xiangyu
    Zhang, Jianwei
    Cao, Wanlin
    Zhu, Yuxuan
    JOURNAL OF BUILDING ENGINEERING, 2022, 53
  • [48] Analytical investigation of thin steel plate shear walls with screwed infill plate
    Vatansever, Cuneyt
    Berman, Jeffrey W.
    STEEL AND COMPOSITE STRUCTURES, 2015, 19 (05) : 1145 - 1165
  • [49] A validated numerical model for predicting the in-plane seismic response of lightly reinforced, low-aspect ratio reinforced concrete shear walls
    Epackachi, Siamak
    Whittaker, Andrew S.
    ENGINEERING STRUCTURES, 2018, 168 : 589 - 611
  • [50] Off-axis tensile strength and evaluation of the in-plane shear strength of paper
    Yoshihara, Hiroshi
    Yoshinobu, Masahiro
    HOLZFORSCHUNG, 2014, 68 (05) : 583 - 590