Nafion-Titanium (IV) Oxide-Graphene Modified Glassy Carbon Electrode (GCE) Based Electrochemical Sensor for the Voltammetric Determination of the β-blocker Bisoprolol Fumarate

被引:2
作者
Kocak, Berna [1 ,2 ]
Ipek, Yeliz [1 ,2 ]
机构
[1] Munzur Univ, Vocat Sch Tunceli, Chem & Chem Proc Technol Dept, Tunceli, Turkey
[2] Munzur Univ, Rare Earth Element Res & Applicat Ctr, Tunceli, Turkey
关键词
Bisoprolol fumarate; differential pulse voltammetry (DPV); electrochemical sensor; graphene; titanium (IV) oxide; PASTE ELECTRODE; AMLODIPINE BESYLATE; TIO2; NANOPARTICLES; HPLC METHOD; HYDROCHLOROTHIAZIDE; VALIDATION; ACETAMINOPHEN; FORMULATIONS; NANOSHEETS; DESIGN;
D O I
10.1080/00032719.2022.2139837
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A Nafion-titanium (IV) oxide-graphene modified glassy carbon electrode (n-TiO2-GR/GCE) was used for the electrochemical determination of bisoprolol fumarate (BF). The modified electrode was prepared by depositing Nafion-titanium (IV) oxide-graphene onto the glassy carbon electrode by simple drop-casting. Differential pulse voltammetry (DPV) and square wave voltammetry (SWV) were used in the electrochemical determination of bisoprolol fumarate. The linear working range of bisoprolol fumarate for n-TiO2-GR/GCE DPV was from 3.0 x 10(-7) to 5.0 x 10(-6 )mol L-1 and the detection limit was 1.01 x 10(-7 )mol L-1. In addition, with this developed method, the determination of bisoprolol fumarate in tablets was successfully performed with a recovery of 98.65%.
引用
收藏
页码:1619 / 1631
页数:13
相关论文
共 51 条
[1]  
Abdelwahab N. S., 2018, European Journal of Chemistry, V9, P331, DOI DOI 10.5155/EURJCHEM.9.4.331-337.1753
[2]   Probing the Electrochemical Properties of Graphene Nanosheets for Biosensing Applications [J].
Alwarappan, Subbiah ;
Erdem, Arzum ;
Liu, Chang ;
Li, Chen-Zhong .
JOURNAL OF PHYSICAL CHEMISTRY C, 2009, 113 (20) :8853-8857
[3]  
Atul AS, 2008, PAK J PHARM SCI, V21, P366
[4]  
Baokar S.S., 2011, INDO AM J PHARM RES, V2, P100
[5]   Fully Validated Simultaneous Determination of Bisoprolol Fumarate and Hydrochlorothiazide in Their Dosage Forms Using Different Voltammetric, Chromatographic, and Spectrophotometric Analytical Methods [J].
Bozal, Burcin ;
Gumustas, Mehmet ;
Dogan-Topal, Burcu ;
Uslu, Bengi ;
Ozkan, Sibel A. .
JOURNAL OF AOAC INTERNATIONAL, 2013, 96 (01) :42-51
[6]   Development, validation and analytical error function of two chromatographic methods with fluorimetric detection for the determination of bisoprolol and metoprolol in human plasma [J].
Braza, AJ ;
Modamio, P ;
Lastra, CF ;
Mariño, EL .
BIOMEDICAL CHROMATOGRAPHY, 2002, 16 (08) :517-522
[7]   Cyclic voltammetric and ac impedance behavior of TiO2 electrodes under UV illumination [J].
Cui, XL ;
Jiang, ZY .
JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2003, 50 (05) :1003-1008
[8]   Desirability Based Optimization and Validation of New RP-HPLC Method for Simultaneous Determination of Bisoprolol Fumarate, Hydrochlorothiazide and Their Impurities [J].
Dobricic, Vladimir ;
Vulovic-Tadic, Miljana ;
Jancic-Stojanovic, Biljana ;
Vladimirov, Sote ;
Cudina, Olivera .
CHROMATOGRAPHIA, 2016, 79 (9-10) :571-579
[9]   TiO2-graphene nanocomposite for electrochemical sensing of adenine and guanine [J].
Fan, Yang ;
Huang, Ke-Jing ;
Niu, De-Jun ;
Yang, Chun-Peng ;
Jing, Qiang-Shan .
ELECTROCHIMICA ACTA, 2011, 56 (12) :4685-4690
[10]   Electrochemistry and voltammetric determination of L-tryptophan and L-tyrosine using a glassy carbon electrode modified with a Nafion/TiO2-graphene composite film [J].
Fan, Yang ;
Liu, Jin-Hang ;
Lu, Hai-Ting ;
Zhang, Qin .
MICROCHIMICA ACTA, 2011, 173 (1-2) :241-247