Differential diagnosis of adrenal adenomas and metastases using spectral parameters in dual-layer detector spectral CT

被引:1
|
作者
Wu, Lei-di [1 ,2 ]
Yue, Xiao-fei [1 ]
Wu, Lin-xia [1 ]
Yang, Ming [1 ]
Chen, Yan [1 ]
Yu, Jie [1 ]
Diao, Nan [1 ]
Zhang, Xiao-hui [3 ]
Zhu, Liang-ru [4 ]
Han, Ping [1 ]
机构
[1] Huazhong Univ Sci & Technol, Union Hosp, Tongji Med Coll, Dept Radiol, Wuhan, Peoples R China
[2] Zhongshan City Peoples Hosp, Dept Radiol, Zhongshan, Peoples R China
[3] Philips Healthcare, Clin Sci, Shanghai, Peoples R China
[4] Huazhong Univ Sci & Technol, Union Hosp, Tongji Med Coll, Div Gastroenterol, Wuhan, Peoples R China
基金
中国国家自然科学基金;
关键词
Computed tomography; Dual-layer detector spectral CT; Spectral parameters; Adrenal adenomas; Adrenal metastases; ENERGY CT; IMAGES; MASSES; PRINCIPLES; LESIONS; MRI;
D O I
10.1007/s00432-023-04931-8
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
ObjectiveTo assess the diagnostic value of spectral parameters in differentiating adrenal adenomas from metastases based on dual-layer detector spectral CT (DLSCT).Materials and methodsPatients with adenomas or metastases who underwent enhanced DLSCT of the adrenals were enrolled. The CT values of virtual non-contrast images (CTVNC), iodine density (ID) values, and Z-effective (Z-eff) values, the normalized iodine density (NID) values, slopes of spectral HU curves (s-SHC), and iodine-to-CTVNC ratios of the tumors were measured in each phase. Receiver operating characteristic (ROC) curves were used to compare the diagnostic values.ResultsNinety-nine patients with 106 adrenal lesions (63 adenomas, 43 metastases) were included. In the venous phase, all spectral parameters were significantly different between adenomas and metastases (all p < 0.05). The combined spectral parameters showed a better diagnostic performance in the venous phase than in other phase (p < 0.05). The iodine-to-CTVNC value had a larger area under the ROC curve (AUC) than the other spectral parameters in the differential diagnosis of adenomas and metastases, with a diagnostic sensitivity and specificity of 74.4% and 91.9%, respectively. In the differential diagnosis of lipid-rich adenomas, lipid-poor adenomas and metastases, the CTVNC value and s-SHC value also had a larger AUC than the other spectral parameters, with a diagnostic sensitivity of 97.7%, 79.1% and specificity of 91.2%, 93.1%, respectively.ConclusionOn DLSCT, the combined spectral parameters in the venous phase could help better distinguish adrenal adenomas from metastases. The iodine-to-CTVNC, CTVNC and s-SHC values had the highest AUC values in differentiating adenomas, lipid-rich adenomas and lipid-poor adenomas from metastases, respectively.
引用
收藏
页码:10453 / 10463
页数:11
相关论文
共 50 条
  • [1] Differential diagnosis of adrenal adenomas and metastases using spectral parameters in dual-layer detector spectral CT
    Lei-di Wu
    Xiao-fei Yue
    Lin-xia Wu
    Ming Yang
    Yan Chen
    Jie Yu
    Nan Diao
    Xiao-hui Zhang
    Liang-ru Zhu
    Ping Han
    Journal of Cancer Research and Clinical Oncology, 2023, 149 : 10453 - 10463
  • [3] Iodine Imaging at Spectral CT with a Dual-Layer Detector
    Ozguner, O.
    Dhanantwari, A.
    Halliburton, S.
    Wen, G.
    Utrup, S.
    Jordan, D.
    MEDICAL PHYSICS, 2016, 43 (06) : 3657 - 3657
  • [4] Unenhanced Dual-Layer Spectral-Detector CT for Characterizing Indeterminate Adrenal Lesions
    Nagayama, Yasunori
    Inoue, Taihei
    Oda, Seitaro
    Tanoue, Shota
    Nakaura, Takeshi
    Morinaga, Jun
    Ikeda, Osamu
    Hirai, Toshinori
    RADIOLOGY, 2021, 301 (02) : 369 - 378
  • [5] Objective Image Characterization of Spectral CT with a Dual-Layer Detector
    Ozguner, O.
    Halliburton, S.
    Dhanantwari, A.
    Wen, G.
    Utrup, S.
    Jordan, D.
    MEDICAL PHYSICS, 2016, 43 (06) : 3836 - 3836
  • [6] Dual-layer detector spectral CT-based machine learning models in the differential diagnosis of solitary pulmonary nodules
    Lu, Hui
    Liu, Kaifang
    Zhao, Huan
    Wang, Yongqiang
    Shi, Bo
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [7] Dual-layer detector spectral CT-based machine learning models in the differential diagnosis of solitary pulmonary nodules
    Hui Lu
    Kaifang Liu
    Huan Zhao
    Yongqiang Wang
    Bo Shi
    Scientific Reports, 14
  • [8] Objective image characterization of a spectral CT scanner with dual-layer detector
    Ozguner, Orhan
    Dhanantwari, Amar
    Halliburton, Sandra
    Wen, Gezheng
    Utrup, Steven
    Jordan, David
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (02):
  • [9] The Application of Dual-layer Spectral Detector CT in Abdominal Vascular Imaging
    Lai, Lu-Yao
    Jiang, Ying
    Shu, Jian
    CURRENT MEDICAL IMAGING, 2023, 19 (14) : 1609 - 1615
  • [10] Noninvasive assessment of liver fibrosis by dual-layer spectral detector CT
    Morita, Koichiro
    Nishie, Akihiro
    Ushijima, Yasuhiro
    Takayama, Yukihisa
    Fujita, Nobuhiro
    Kubo, Yuichiro
    Ishimatsu, Keisuke
    Yoshizumi, Tomoharu
    Maehara, Junki
    Ishigami, Kousei
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 136