Thermo-mechanical properties in bending of a multizone nickel-titanium archwire: A retrieval analysis

被引:4
作者
Roulias, Panagiotis [1 ]
Mylonopoulou, Ioulia-Maria [1 ]
Sifakakis, Iosif [1 ,4 ]
Bourauel, Christoph [2 ]
Eliades, Theodore [3 ]
机构
[1] Natl & Kapodistrian Univ Athens, Sch Dent, Dept Orthodont, Athens, Greece
[2] Univ Hosp Bonn, Sch Dent, Dept Oral Technol, Bonn, Germany
[3] Univ Zurich, Ctr Dent Med, Clin Orthodont & Paediat Dent, Zurich, Switzerland
[4] Natl & Kapodistrian Univ Athens, Sch Dent, Dept Orthodont, 2 Thibon Str, Athens 11527, Greece
关键词
Archwire; Biomaterial science; Nitinol; Transformation temperature; MECHANICAL-PROPERTIES; ORTHODONTIC ARCHWIRES; TEMPERATURE; SURFACE; APPARATUS;
D O I
10.4041/kjod22.183
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: This study aimed to compare the mechanical and thermal properties in the anterior and posterior segments of new and retrieved specimens of a commercially available multizone superelastic nickel-titanium (NiTi) archwire.Methods: The following groups of 0.016 x 0.022-inch Bioforce NiTi archwires were compared: a) anterior and b) posterior segments of new specimens and c) anterior and d) posterior segments of retrieved specimens. Six specimens were evaluated in each group, by three-point bending and bend and free recovery tests. Bending moduli (Eb) were calculated. Furthermore, the new specimens were evaluated with scanning electron microscopy/energy-dispersive X-ray spectrometry. A multiple linear regression model with a random intercept at the wire level was applied for data analysis.Results: The forces in the posterior segments or new specimens were higher than those recorded in the anterior segments or retrieved specimens, respectively. Accordingly, Eb also varied. Higher austenite start and austenite finish (Af) temperatures were recorded in the anterior segments. No statistically significant differences were found for these temperatures between retrieved and new wires. The mean elemental composition was (weight percentage): Ni, 52.6 +/- 0.5; Ti, 47.4 +/- 0.5.Conclusions: The existence of multiple force zones was confirmed in new and retrieved Bioforce archwires. The retrieved archwires demonstrated lower forces during the initial stages of deactivation in three-point bending tests, compared with new specimens. The Af temperature of these archwires may lie higher than the regular intraoral temperature. Even at 2 mm deflections, the forces recorded from these archwires may lie beyond biologically safe limits.
引用
收藏
页码:89 / 98
页数:10
相关论文
共 52 条
[1]  
Aghili Hossein, 2015, J Dent (Tehran), V12, P695
[2]   Variations in surface roughness of seven orthodontic archwires: an SEM-profilometry study [J].
Amini, Fariborz ;
Rakhshan, Vahid ;
Pousti, Maryam ;
Rahimi, Hajir ;
Shariati, Mahsa ;
Aghamohamadi, Bahareh .
KOREAN JOURNAL OF ORTHODONTICS, 2012, 42 (03) :129-137
[3]  
Andreasen G, 1985, Quintessence Int, V16, P623
[4]  
ASTM International, 2016, F208206 ASTM
[5]  
ASTM International, 2016, F2082F2082M16 ASTM
[6]  
ASTM International, 2017, F200417 ASTM
[7]   Load-deflection characteristics of superelastic nickel-titanium wires [J].
Bartzela, Theodosia N. ;
Senn, Christiane ;
Wichelhaus, Andrea .
ANGLE ORTHODONTIST, 2007, 77 (06) :991-998
[8]   An evaluation of the transition temperature range of super-elastic orthodontic NiTi springs using differential scanning calorimetry [J].
Barwart, O ;
Rollinger, JM ;
Burger, A .
EUROPEAN JOURNAL OF ORTHODONTICS, 1999, 21 (05) :497-502
[9]  
Biermann MC, 2007, ANGLE ORTHOD, V77, P499, DOI 10.2319/0003-3219(2007)077[0499:TAOAAC]2.0.CO
[10]  
2