'Post-Close' Femoral Arterial Haemostasis at Endovascular Aneurysm Repair using a Dedicated Large-Bore Vascular Closure Device: A Prospective Real-World Audit

被引:5
作者
Chaudhuri, A. [1 ]
机构
[1] Bedfordshire Hosp NHS Fdn Trust, Bedfordshire Milton Keynes Vasc Ctr, Kempston Rd, Bedford MK42 9DJ, England
关键词
Percutaneous EVAR; Large-bore femoral access; Post-close; Vascular closure devices; Outcomes audit; PERCUTANEOUS ACCESS; PLUG; EVAR;
D O I
10.1007/s00270-023-03437-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
PurposePercutaneous access for endovascular aneurysm repair (EVAR) is commonplace, with its attendant benefits. The combination of continued reduction in device profile and evolution of vascular closure device (VCD) design drives successful and safe percutaneous EVAR. A new such VCD is the MANTA Large-Bore Closure Device designed in two iterations for closure of arterial defects from 10 to 25F. We present a prospective audit of 131 large-bore femoral closures using an 'all-comers' approach to device selection.Materials and methodsOne hundred and thirty-one large-bore femoral arterial defects were analysed. Both 14F and 18F MANTA VCDs were deployed in this series as per instructions for use. Primary objectives were technical success, particularly successful deployment, and haemostasis achieved. Failures were denoted as failure to deploy; failure to achieve haemostasis was denoted as active bleeding, haematoma, or pseudoaneurysm formation requiring intervention. Later complications assessed were vessel occlusion/thrombosis or stenosis.ResultsSeventy-six patients (65 males and 11 females, age 75.2 +/- 8.7 years) underwent a range of procedures including EVAR (n = 66), TEVAR (n = 2), and reinterventions (n = 8) requiring large-bore percutaneous femoral arterial access in 131 groins. Of these, the 14F MANTA VCD was used in 61 closures (defects ranging from 12 to 18F) and the 18F in 70 closures (defects ranging from 16 to 24F). Deployments achieved successful haemostasis in 120 (91.6%), and failures occurred in 11(8.4%) groins.ConclusionsThis study indicates that a post-close approach using the novel MANTA Large-Bore Closure Device can be undertaken successfully to close a range of large-bore femoral arterial defects at EVAR/TEVAR with an acceptable rate of complications.
引用
收藏
页码:835 / 843
页数:9
相关论文
共 32 条
[1]  
Ali Noman, 2019, J Cardiol Cases, V19, P81, DOI 10.1016/j.jccase.2018.12.001
[2]   Real-time ultrasound-guided bedside closure of arteriotomy wound using MANTA closure device during venoarterial extracorporeal membrane oxygenation decannulation [J].
Au, Shek-Yin ;
Fong, Ka-Man ;
Ng, Wing-Yiu George ;
Lee, Kang-Yin Michael ;
So, Sheung-On ;
Leung, Kit-Hung Anne .
PERFUSION-UK, 2021, 36 (02) :118-121
[3]   MANTA versus ProGlide vascular closure devices in transfemoral transcatheter aortic valve implantation [J].
Biancari, Fausto ;
Romppanen, Hannu ;
Savontaus, Mikko ;
Siljander, Antti ;
Makikallio, Timo ;
Piira, Olli-Pekka ;
Piuhola, Jarkko ;
Vilkki, Viivi ;
Ylitalo, Antti ;
Vasankari, Tuija ;
Airaksinen, Juhani K. E. ;
Niemela, Matti .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 263 :29-31
[4]   Femoral Arterial Haemostasis Using an Anchored Collagen Plug after Percutaneous EVAR with an Ultra-Low Profile Device: Prospective Audit of an Evolving "Post-Close" Technique [J].
Chaudhuri, A. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2017, 54 (02) :241-246
[5]  
Chaudhuri A., 2015, EJVES SHORT REP, V29, P18, DOI [10.1016/j.ejvssr.2015.10.001, DOI 10.1016/J.EJVSSR.2015.10.001]
[6]   Newer Generation Vascular Closure Devices: Plugging the Hole in the Artery, What About the One in the Purse? [J].
Chaudhuri, Arindam .
JOURNAL OF ENDOVASCULAR THERAPY, 2020, 27 (06) :977-978
[7]  
Chaudhuri Arindam, 2018, EJVES Short Rep, V40, P12, DOI 10.1016/j.ejvssr.2018.08.002
[8]   Percutaneous axillary arteriotomy closure during transcatheter aortic valve replacement using the MANTA device [J].
De Palma, Rodney ;
Ruck, Andreas ;
Settergren, Magnus ;
Saleh, Nawzad .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2018, 92 (05) :998-1001
[9]   A Meta-Analysis of Outcome After Percutaneous Endovascular Aortic Aneurysm Repair Using Different Size Sheaths or Endograft Delivery Systems [J].
Georgiadis, George S. ;
Antoniou, George A. ;
Papaioakim, Miltos ;
Georgakarakos, Efstratios ;
Trellopoulos, George ;
Papanas, Nikolaos ;
Lazarides, Miltos K. .
JOURNAL OF ENDOVASCULAR THERAPY, 2011, 18 (04) :445-459
[10]   Early Outcomes After Percutaneous Closure of Access Site in Transfemoral Transcatheter Valve Implantation Using the Novel Vascular Closure Device Collagen Plug-Based MANTA [J].
Gheorghe, Livia ;
Brouwer, Jorn ;
Mathijssen, Harold ;
Nijenhuis, Vincent J. ;
Rensing, Benno J. W. M. ;
Swaans, Martin J. ;
Yin, Dean R. P. P. Chan Pin ;
Heijmen, Robin H. ;
De Kroon, Tom ;
Sonker, Uday ;
Van der Heyden, Jan A. S. ;
Ten Berg, Jurrien M. .
AMERICAN JOURNAL OF CARDIOLOGY, 2019, 124 (08) :1265-1271