Clinical usefulness of tissue acquisition of pancreatic cystic lesions using an endoscopic ultrasound-guided needle for histological analysis

被引:2
|
作者
de Castro, Juliana Silveira Lima [1 ,2 ]
Taglieri, Eloy [2 ,3 ,4 ]
Neto, Otavio Micelli [2 ,3 ,4 ]
Guerra, Joao Guilherme [2 ,3 ]
Venco, Filadelfio Euclides [5 ]
Andrade, Eliza [2 ]
Seraphim, Alvaro Moura [2 ]
Romanini, Samuel Galante [4 ]
Torres, Isabela Trindade [4 ]
Serrano, Juan Pablo Roman [6 ]
Goldman, Suzan Menasce [1 ]
Kemp, Rafael [7 ]
dos Santos, Jose Sebastiao [7 ]
Ardengh, Jose Celso [1 ,3 ,7 ]
机构
[1] Univ Fed Sao Paulo, Dept Diagnost Imagem, Diagnost Imaging, Sao Paulo, Brazil
[2] ACCamargo Canc Ctr, Endoscopy, Sao Paulo, Brazil
[3] Hosp Moriah, Endoscopy, Sao Paulo, Brazil
[4] Hosp 9 Julho, Endoscopy, Sao Paulo, Brazil
[5] Hosp Moriah, Pathol, Sao Paulo, Brazil
[6] Hosp Gen Luis Vernaza, Endoscopy, Guayaquil, Ecuador
[7] Univ Sao Paulo, Hosp Clin, Ribeirao Preto, Brazil
关键词
Fine-needle aspiration/biopsy; Endoscopic ultrasonography; Intervention EUS; Pancreas; Tissue diagnosis; PAPILLARY MUCINOUS NEOPLASMS; SEROUS CYSTADENOMA; ADVERSE EVENTS; ASPIRATION; DIAGNOSIS; EUS; FLUID; DIFFERENTIATION; ENDOMICROSCOPY; CLASSIFICATION;
D O I
10.1055/a-2240-0678
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and study aims There are rare data on the usefulness of endosonography-guided tissue acquisition (EUS-TA) in patients with pancreatic cystic lesions (PCLs). This study aimed to determine the accuracy of EUS-TA with ProCore 20G (PC20) for differentiating between mucinous neoplasia (MN) and non-MNs (n-MN) and identifying malignant PCLs, as well as its adverse events (AEs) in patients with PCLs without a classificatory diagnosis by imaging exams. Patients and methods In this observational, retrospective, single-center study, all patients with PCL who underwent EUS-TA due to diagnostic doubts in imaging studies were consecutively recruited from June 2017 to December 2021. The outcomes were to determine the diagnostic accuracy of EUS-TA with PC20 for differentiating between MN and n-MN, identifying malignant PCLs, and the AEs. Results Herein, 145 patients underwent EUS-TA, with 83 women (57.2%) and a mean age of 62.2 years. The mean size was 2.3 cm, with 81 patients (77.9%) having a PCL < 3.0 cm. The final diagnosis was made by EUS-TA (n = 81), surgery (n = 58), and follow-up (n = 6). The sensitivity, specificity, positive and negative predictive values, and accuracy for differentiating between MNs and n-MNs and identifying malignant PCLs were 92.6%, 98.4%, 98.7%, 91.3%, and 95.2% (kappa=0.9), and 92%, 99.2%, 95.8%, 98.3%, and 97.9% (kappa = 0.93), respectively. The AE rate was 2.7%, with no deaths in this cohort. Conclusions EUS-TA with PC20 has high accuracy and technical success with a low AE rate for PCL diagnosis.
引用
收藏
页码:E155 / E163
页数:9
相关论文
共 50 条
  • [41] Endoscopic Ultrasound-Guided Tissue Acquisition Using Fork-Tip Needle for Subepithelial Lesions: A Single-Center Validation Study
    Watanabe, Masafumi
    Okuwaki, Kosuke
    Iwai, Tomohisa
    Kida, Mitsuhiro
    Imaizumi, Hiroshi
    Adachi, Kai
    Tamaki, Akihiro
    Ishizaki, Junro
    Hanaoka, Taro
    Kusano, Chika
    DIGESTIVE DISEASES AND SCIENCES, 2024, 69 (07) : 2567 - 2572
  • [42] Diagnostic yields of endoscopic ultrasound-guided fine-needle tissue acquisition according to the gastric location
    Kim, Dong Hyun
    Park, Chang-Hwan
    Park, Seon-Young
    Cho, Eunae
    Kim, Hyun Soo
    Choi, Sung Kyu
    MEDICINE, 2021, 100 (25) : E26477
  • [43] Clinical Usefulness of Endoscopic Ultrasound-Guided Fine Needle Aspiration for Gastric Subepithelial Lesions Smaller than 2 cm
    Akahoshi, Kazuya
    Oya, Masafumi
    Koga, Tadashi
    Koga, Hidenobu
    Motomura, Yasuaki
    Kubokawa, Masaru
    Gibo, Jyuya
    Nakamura, Kazuhiko
    JOURNAL OF GASTROINTESTINAL AND LIVER DISEASES, 2014, 23 (04) : 405 - 412
  • [44] Needle Tract Seeding after Endoscopic Ultrasound Tissue Acquisition of Pancreatic Lesions: A Systematic Review and Meta-Analysis
    Facciorusso, Antonio
    Crino, Stefano Francesco
    Gkolfakis, Paraskevas
    Ramai, Daryl
    Mangiavillano, Benedetto
    Castillo, Juliana Londono
    Chandan, Saurabh
    Mohan, Babu P.
    D'Errico, Francesca
    Decembrino, Francesco
    Domislovic, Viktor
    Anderloni, Andrea
    DIAGNOSTICS, 2022, 12 (09)
  • [45] Overlooked risk for needle tract seeding following endoscopic ultrasound-guided minimally invasive tissue acquisition
    Gao, Ruo-Yu
    Wu, Ben-Hua
    Shen, Xin-Ying
    Peng, Tie-Li
    Li, De-Feng
    Wei, Cheng
    Yu, Zhi-Chao
    Luo, Ming-Han
    Xiong, Feng
    Wang, Li-Sheng
    Yao, Jun
    WORLD JOURNAL OF GASTROENTEROLOGY, 2020, 26 (40) : 6182 - 6194
  • [46] Ultrasound-Guided Percutaneous Fine-Needle Aspiration of 545 Focal Pancreatic Lesions
    Zamboni, Giulia A.
    D'Onofrio, Mirko
    Idili, Antonio
    Malago, Roberto
    Iozzia, Roberta
    Manfrin, Erminia
    Mucelli, Roberto Pozzi
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (06) : 1691 - 1695
  • [47] Accuracy of endoscopic ultrasound-guided fine needle aspiration cytology on the differentiation of malignant and benign pancreatic cystic lesions: A single-center experience
    Oguz, Dilek
    Oztas, Erkin
    Kalkan, Ismail Hakki
    Tayfur, Oyku
    Cicek, Bahattin
    Aydog, Gulden
    Kurt, Mevlut
    Beyazit, Yavuz
    Etik, Digdem
    Nadir, Isilay
    Sahin, Burhan
    JOURNAL OF DIGESTIVE DISEASES, 2013, 14 (03) : 132 - 139
  • [48] Endoscopic ultrasound-guided tissue acquisition: Techniques and challenges
    Rana, Atul
    Rana, Surinder S.
    JOURNAL OF CYTOLOGY, 2019, 36 (01) : 1 - 7
  • [49] Risk of Pancreatitis After Endoscopic Ultrasound-Guided Fine-Needle Aspiration of Pancreatic Cystic Lesions: A Systematic Review and Meta-Analysis
    Magahis, Patrick T.
    Chhoda, Ankit
    Berzin, Tyler M.
    Farrell, James J.
    Wright, Drew N.
    Rizvi, Anam
    Hanscom, Mark
    Carr-Locke, David L.
    Sampath, Kartik
    Sharaiha, Reem Z.
    Mahadev, SriHari
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2024, 119 (11) : 2174 - 2186
  • [50] Fine-needle biopsy with 19G needle is effective in combination with endoscopic ultrasound-guided tissue acquisition for genomic profiling of unresectable pancreatic cancer
    Ikeda, Go
    Hijioka, Susumu
    Nagashio, Yoshikuni
    Maruki, Yuta
    Ohba, Akihiro
    Hisada, Yuya
    Yoshinari, Motohiro
    Harai, Shota
    Kitamura, Hidetoshi
    Koga, Takehiko
    Murashima, Yumi
    Maehara, Kosuke
    Okada, Mao
    Yamashige, Daiki
    Okamoto, Kohei
    Hara, Hidenobu
    Hagiwara, Yuya
    Agarie, Daiki
    Takasaki, Tetsuro
    Takeshita, Kotaro
    Kawasaki, Yuki
    Kondo, Shunsuke
    Morizane, Chigusa
    Ueno, Hideki
    Hiraoka, Nobuyoshi
    Yatabe, Yasushi
    Saito, Yutaka
    Iwakiri, Katsuhiko
    Okusaka, Takuji
    DIGESTIVE ENDOSCOPY, 2023, 35 (01) : 124 - 133