An Institutional Overview of Gastrointestinal Bleeding Among 563 Continuous-Flow Left Ventricular Assist Device Recipients

被引:0
|
作者
Kalinowski, Michael [1 ,5 ]
Kothari, Shana [1 ]
Kobeszko, Matthew [1 ]
Josephson, Greta [1 ]
Glowacki, Nicole [2 ]
Cotts, William [3 ]
Pauwaa, Sunil [3 ]
Tatooles, Antone [4 ]
Elkhatib, Imad [1 ]
Silva, Rogelio [1 ]
机构
[1] Advocate Christ Med Ctr, Gastroenterol, Oak Lawn, IL USA
[2] Advocate Aurora Hlth, Advocate Aurora Res Inst, Downers Grove, IL USA
[3] Advocate Christ Med Ctr, Cardiol, Oak Lawn, IL USA
[4] Advocate Christ Med Ctr, Cardiothorac Surg, Oak Lawn, IL USA
[5] 456 Warner Ave, North Mahtomedi, MN 90024 USA
来源
TECHNIQUES AND INNOVATIONS IN GASTROINTESTINAL ENDOSCOPY | 2023年 / 25卷 / 04期
关键词
Gastrointestinal bleeding; Left ventricular assist device; Push enteroscopy;
D O I
10.1016/j.tige.2023.04.001
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
BACKGROUND AND AIMS: Gastrointestinal bleeding (GIB) is a common morbidity among continuous-flow left ventricular assist device (CF-LVAD) recipients. The study objectives were to investigate the incidence, recurrence, risk factors, and medical and endoscopic management of GIB among CF-LVAD patients.METHODS: This is a single-center retrospective study analyzing 563 CF-LVAD recipients implanted at a large tertiary referral center from 2007 to 2018 with 619 bleeding events characterized. Patients with device exchanges or history of right ventricular assist devices were excluded. Chart review data pertaining to demographics, LVAD characteristics, endoscopic reports, and medications were collected.RESULTS: The incidence of GIB was 44%, with a median time to first bleed of 133 days and a recurrence rate of 53%. Approximately 13% of patients had >= 5 GIB events. There is an association of reduced GIB among patients taking angiotensin-converting enzyme inhibitors (ACEis). There was no association with GIB and acid-reducing medications, antiplatelet medications, and history of GIB before device implantation. Arteriovenous malformations were the most common bleeding etiology. CF-LVAD patients that bled more frequently were older, had their CF-LVAD longer, and bled earlier after LVAD implantation.CONCLUSION: This is the largest comprehensive single-center GIB study among CF-LVAD recipients. The incidence and recurrence of GIB among CF-LVAD recipients is underreported. Push enteroscopy improves diagnostic yield for upper GIB. Special attention should be given to CF-LVAD patients that bleed within the first 18 days of implantation. There is an associative, dose-dependent benefit of ACEi medications among CF-LVAD recipients. Further studies on this effect are warranted.
引用
收藏
页码:307 / 314
页数:8
相关论文
共 50 条
  • [1] AN INSTITUTIONAL REVIEW OF GASTROINTESTINAL BLEEDING AMONG 563 CONTINUOUS FLOW LEFT VENTRICULAR ASSIST DEVICE RECIPIENTS
    Kalinowski, Michael
    Kothari, Shana
    Kobeszko, Matthew
    Josephson, Greta
    Cotts, William
    Pauwaa, Sunil
    Tatooles, Antone
    Silva, Rogelio G.
    Elkhatib, Imad E.
    GASTROINTESTINAL ENDOSCOPY, 2020, 91 (06) : AB605 - AB606
  • [2] Gastrointestinal bleeding on continuous-flow left ventricular assist device therapy
    Hammer, Yoav
    Bitar, Abbas
    Aaronson, Keith D.
    ESC HEART FAILURE, 2023, 10 (04): : 2214 - 2224
  • [3] INVESTIGATION OF REPEAT GASTROINTESTINAL BLEEDING AMONG CONTINUOUS FLOW LEFT VENTRICULAR ASSIST DEVICE RECIPIENTS
    Kalinowski, Michael
    Kothari, Shana
    Kobeszko, Matthew
    Josephson, Greta
    Cotts, William
    Pauwaa, Sunil
    Tatooles, Antone
    Elkhatib, Imad E.
    Silva, Rogelio G.
    GASTROENTEROLOGY, 2020, 158 (06) : S248 - S249
  • [4] Continuous-Flow Left Ventricular Assist Device-Related Gastrointestinal Bleeding
    Kim, Ju H.
    Brophy, Donald F.
    Shah, Keyur B.
    CARDIOLOGY CLINICS, 2018, 36 (04) : 519 - +
  • [5] Gastrointestinal bleeding with continuous-flow left ventricular assist devices
    Amer S.
    Shah P.
    Hassan S.
    Clinical Journal of Gastroenterology, 2015, 8 (2) : 63 - 67
  • [6] Characterization and timing of gastrointestinal bleeding in continuous flow left ventricular assist device recipients
    Kapuria, Devika
    Khumri, Taiyeb
    Shamim, Shariq
    Surana, Pallavi
    Khan, Salman
    Al-Khalisi, Nabil
    Aggarwal, Sanjeev
    Koh, Christopher
    Chhabra, Rajiv
    HELIYON, 2020, 6 (09)
  • [7] Investigation of Gastrointestinal Bleeding Among Left Ventricular Assist Device Recipients
    Kalinowski, Michael
    Kothari, Shana
    Kobeszko, Matthew
    Josephson, Greta
    Cotts, William
    Pauwaa, Sunil
    Tatooles, Antone
    Elkhatib, Imad
    Silva, Rogelio
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2019, 114 : S338 - S339
  • [8] Gastrointestinal Bleeding During Continuous-Flow Left Ventricular Assist Device Support State of the Field
    Kataria, Rachna
    Jorde, Ulrich P.
    CARDIOLOGY IN REVIEW, 2019, 27 (01) : 8 - 13
  • [9] Continuous-Flow Left Ventricular Assist Device
    Landzaat, Lindy H.
    Sinclair, Christian T.
    Rosielle, Drew A.
    NEW ENGLAND JOURNAL OF MEDICINE, 2010, 362 (12): : 1149 - 1149
  • [10] Characteristics of Gastrointestinal Bleeding After Placement of Continuous-Flow Left Ventricular Assist Device: A Case Series
    Marsano, Joseph
    Desai, Jay
    Chang, Shannon
    Chau, Michelle
    Pochapin, Mark
    Gurvits, Grigoriy E.
    DIGESTIVE DISEASES AND SCIENCES, 2015, 60 (06) : 1859 - 1867