Label-Free Quantification of Nanoencapsulated Piperonyl Esters in Cosmetic Hydrogels Using Raman Spectroscopy

被引:2
|
作者
Elderderi, Suha [1 ,2 ]
Bonnier, Franck [3 ]
Perse, Xavier [1 ]
Byrne, Hugh J. [4 ]
Yvergnaux, Florent [5 ]
Chourpa, Igor [1 ]
Elbashir, Abdalla A. [6 ,7 ]
Munnier, Emilie [1 ]
机构
[1] Univ Tours, Fac Pharm, EA Nanomedicaments & Nanosondes 6295, 31 Ave Monge, F-37200 Tours, France
[2] Univ Gezira, Fac Pharm, Dept Pharmaceut Chem, POB 20, Wad Madani 21111, Sudan
[3] LVMH Rech, 185 Ave Verdun, F-45804 Saint Jean De Braye, France
[4] TU Dublin, FOCAS Res Inst, City Campus, Dublin 8, Ireland
[5] Bioeurope Grp Solabia, Route Oulins, F-28260 Anet, France
[6] King Faisal Univ, Coll Sci, Dept Chem, POB 400, Al Hasa 31982, Saudi Arabia
[7] Univ Khartoum, Fac Sci, Dept Chem, POB 321, Khartoum 11115, Sudan
关键词
Raman spectroscopy; label-free quantification; alginate nanocarriers; hydrogels; partial least squares regression; NANOSTRUCTURED LIPID CARRIERS; PRINCIPAL COMPONENT ANALYSIS; FTIR; DISCRIMINATION; IDENTIFICATION; NANOCARRIERS; HPLC; TOOL;
D O I
10.3390/pharmaceutics15061571
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Raman spectroscopy is a well-established technique for the molecular characterisation of samples and does not require extensive pre-analytical processing for complex cosmetic products. As an illustration of its potential, this study investigates the quantitative performance of Raman spectroscopy coupled with partial least squares regression (PLSR) for the analysis of Alginate nanoencapsulated Piperonyl Esters (ANC-PE) incorporated into a hydrogel. A total of 96 ANC-PE samples covering a 0.4% w/w-8.3% w/w PE concentration range have been prepared and analysed. Despite the complex formulation of the sample, the spectral features of the PE can be detected and used to quantify the concentrations. Using a leave-K-out cross-validation approach, samples were divided into a training set (n = 64) and a test set, samples that were previously unknown to the PLSR model (n = 32). The root mean square error of cross-validation (RMSECV) and prediction (RMSEP) was evaluated to be 0.142% (w/w PE) and 0.148% (w/w PE), respectively. The accuracy of the prediction model was further evaluated by the percent relative error calculated from the predicted concentration compared to the true value, yielding values of 3.58% for the training set and 3.67% for the test set. The outcome of the analysis demonstrated the analytical power of Raman to obtain label-free, non-destructive quantification of the active cosmetic ingredient, presently PE, in complex formulations, holding promise for future analytical quality control (AQC) applications in the cosmetics industry with rapid and consumable-free analysis.
引用
收藏
页数:19
相关论文
共 50 条
  • [41] Raman Spectroscopy and Aptamers for a Label-Free Approach: Diagnostic and Application Tools
    Scatena, Elisa
    Baiguera, Silvia
    Del Gaudio, Costantino
    JOURNAL OF HEALTHCARE ENGINEERING, 2019, 2019
  • [42] Label-Free in Situ Quantification of Drug in Living Cells at Micromolar Levels Using Infrared Spectroscopy
    Chan, K. L. Andrew
    Fale, Pedro L. V.
    ANALYTICAL CHEMISTRY, 2014, 86 (23) : 11673 - 11679
  • [43] Label-free and Raman dyes-free surface-enhanced Raman spectroscopy for detection of DNA
    Qian, Yong
    Fan, Taotao
    Yao, Yao
    Shi, Xin
    Liao, Xianjiu
    Zhou, Fuyi
    Gao, Fenglei
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 254 : 483 - 489
  • [44] Label-Free Evaluation of Chromatin Condensation in Human Normal Morphology Sperm Using Raman Spectroscopy
    M. Y. Jahmani
    M. E. Hammadeh
    M. A. Al Smadi
    Marko K. Baller
    Reproductive Sciences, 2021, 28 : 2527 - 2539
  • [45] Differential diagnosis of otitis media with effusion using label-free Raman spectroscopy: A pilot study
    Pandey, Rishikesh
    Zhang, Chi
    Kang, Jeon W.
    Desai, Parind M.
    Dasari, Ramachandra R.
    Barman, Ishan
    Valdez, Tulio A.
    JOURNAL OF BIOPHOTONICS, 2018, 11 (06)
  • [46] Biomolecular phenotyping and heterogeneity assessment of mesenchymal stromal cells using label-free Raman spectroscopy
    Rocha, R. A.
    Fox, J. M.
    Genever, P. G.
    Hancock, Y.
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [47] Label-free monitoring of tissue biochemistry following traumatic brain injury using Raman spectroscopy
    Surmacki, Jakub Maciej
    Ansel-Bollepalli, Laura
    Pischiutta, Francesca
    Zanier, Elisa R.
    Ercole, Ari
    Bohndiek, Sarah Elizabeth
    ANALYST, 2017, 142 (01) : 132 - 139
  • [48] Non-contact, Label-free Monitoring of Cells and Extracellular Matrix using Raman Spectroscopy
    Votteler, Miriam
    Berrio, Daniel A. Carvajal
    Pudlas, Marieke
    Walles, Heike
    Schenke-Layland, Katja
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2012, (63):
  • [49] Using Label-Free Raman Spectroscopy Integrated with Microfluidic Chips to Probe Ferroptosis Networks in Cells
    Muhammad, Muhammad
    Shao, Chang-Sheng
    Nawaz, Raziq
    Aligayev, Amil
    Hassan, Muhammad
    Bashir, Mona Alrasheed
    Iqbal, Jamshed
    Zhan, Jie
    Huang, Qing
    APPLIED SPECTROSCOPY, 2024,
  • [50] Label-free Noninvasive Characterization of Osteoclast Differentiation Using Raman Spectroscopy Coupled with Multivariate Analysis
    Jung, Gyeong Bok
    Kang, In Soon
    Lee, Young Ju
    Kim, Dohyun
    Park, Hun-Kuk
    Lee, Gi-Ja
    Kim, Chaekyun
    CURRENT OPTICS AND PHOTONICS, 2017, 1 (04) : 412 - 420