Cryoballoon temperature parameters during cryoballoon ablation predict pulmonary vein reconnection and atrial fibrillation recurrence

被引:3
|
作者
Chahine, Yaacoub [1 ]
Afroze, Tanzina [1 ]
Bifulco, Savannah F. [2 ]
Macheret, Fima [1 ]
Abdulsalam, Nashwa [1 ]
Boyle, Patrick M. [2 ,3 ,4 ]
Akoum, Nazem [1 ,2 ]
机构
[1] Univ Washington, Div Cardiol, Seattle, WA 98195 USA
[2] Univ Washington, Dept Bioengn, 1959 NE Pacific St, Seattle, WA 98195 USA
[3] Univ Washington, Inst Stem Cell & Regenerat Med, Seattle, WA 98195 USA
[4] Univ Washington, Ctr Cardiovasc Biol, Seattle, WA 98195 USA
关键词
Atrial fibrillation; Cryoballoon ablation; Pulmonary vein reconnection; Arrhythmia recurrence; Balloon temperature; ANTIARRHYTHMIC-DRUG THERAPY; CATHETER ABLATION;
D O I
10.1007/s10840-022-01429-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Cryoballoon ablation (CBA) is an established approach for rhythm management of atrial fibrillation (AF). We sought to assess balloon temperature (BT) parameters as predictors of pulmonary vein (PV) reconnection within the index procedure and AF recurrence following CBA. Methods BT was monitored in 119 AF patients undergoing CBA. PVs were assessed for reconnection during the procedure and patients were followed for arrhythmia recurrence. Results PV reconnection was identified in 39 (8.3%) of 471 PVs. BT was significantly colder in the absence of PV reconnection (30 s: - 33.5 degrees C [- 36; - 30] vs - 29.5 degrees C [- 35; - 25.5], p = 0.001; 60 s: - 41 degrees C [- 44; - 37] vs - 36.5 degrees C [- 42; - 33.5], p < 0.001; nadir: - 47 degrees C [- 52; - 43] vs - 41.5 degrees C [- 47; - 38], p < 0.001). PV reconnection was associated with significantly longer time to reach - 15 degrees C and - 40 degrees C (14.5 s [11.5-18.5] vs 12 s [10-15.5], p = 0.023; and 75 s [40-95.5] vs 46 s [37-66.75], p = 0.005) and shorter rewarming time (5.75 s [4.75-8.5] vs 7 s [6-9], p = 0.012). ROC analysis of these procedural parameters had an AUC = 0.71 in predicting PV reconnection. AF recurrence occurred in 51 (42.8%) patients. Kaplan-Meier analysis showed better arrhythmia-free survival for patients in whom BT decreased below - 40 degrees C in all PVs and patients who had no early PV reconnections, compared to patients in whom BT below - 40 degrees C was not achieved in at least one PV (log rank = 6.3, p = 0.012) and patients who had PV reconnections (log rank = 4.1, p = 0.043). Conclusions Slower BT decline, warmer BT nadir, and faster rewarming time predict early PV reconnection. Absence of early PV reconnections and BT dropping below - 40 degrees C in all PVs during CBA are associated with lower rates of AF recurrence.
引用
收藏
页码:1367 / 1373
页数:7
相关论文
共 50 条
  • [41] Cryoballoon ablation of atrial fibrillation in patients with atypical right pulmonary vein anatomy
    Pichard, Camille
    Nicolas, Amelie
    Galand, Vincent
    Coquard, Charlene
    Behar, Nathalie
    Cherel, Celine
    Daubert, Jean-Claude
    Mabo, Philippe
    Leclercq, Christophe
    Pavin, Dominique
    Lederlin, Mathieu
    Martins, Raphael P.
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2020, 113 (11) : 690 - 700
  • [42] Headache during cryoballoon ablation for atrial fibrillation
    Pison, Laurent
    Peeters, Pim
    Blaauw, Yuri
    Vernooy, Kevin
    Kumar, Narendra
    Philippens, Suzanne
    Crijns, Harry J.
    Vlaeyen, Johan
    Schoenen, Jean
    Timmermans, Carl
    EUROPACE, 2015, 17 (06): : 898 - 901
  • [43] Long Term Durability of Pulmonary vein isolation with Zero-Fluoroscopy Cryoballoon Ablation During Repeat Ablation for Atrial Fibrillation Recurrence
    Gabrah, Kirollos
    Doty, Brandon
    Lee, Bridget
    Mahtani, Arun
    Brider, Jamracus
    Nair, Devi
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2024, 35 (06) : 1271 - 1272
  • [44] Cryoballoon Ablation of Atrial Fibrillation
    Kuck, Karl-Heinz
    Fuernkranz, Alexander
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2010, 21 (12) : 1427 - 1431
  • [45] Cryoballoon in atrial fibrillation ablation
    Schmidt, M.
    Dorwarth, U.
    Straube, F.
    Wankerl, M.
    Krieg, J.
    Leber, A. W.
    Huber, A.
    Hoffmann, E.
    HERZ, 2012, 37 (02) : 153 - 158
  • [46] Incremental value of left atrial strain to predict atrial fibrillation recurrence after cryoballoon ablation
    Motoc, Andreea
    Luchian, Maria-Luiza
    Scheirlynck, Esther
    Roosens, Bram
    Chameleva, Hadischat
    Gevers, Maxim
    Galloo, Xavier
    von Kemp, Berlinde
    Ramak, Robbert
    Sieira, Juan
    de Asmundis, Carlo
    Chierchia, Gian-Battista
    Magne, Julien
    Weytjens, Caroline
    Droogmans, Steven
    Cosyns, Bernard
    PLOS ONE, 2021, 16 (11):
  • [47] Incremental value of left atrial strain to predict atrial fibrillation recurrence after cryoballoon ablation
    Motoc, Andreea
    Luchian, Maria-Luiza
    Scheirlynck, Esther
    Roosens, Bram
    Chameleva, Hadischat
    Galloo, Xavier
    von Kemp, Berlinde
    Ramak, Robbert
    Sieira, Juan
    de Amundis, Carlo
    Chierchia, Gian-Battista
    Magne, Julien
    Weytjens, Caroline
    Droogmans, Steven
    Cosyns, Bernard
    ACTA CARDIOLOGICA, 2023, 78 : 28 - 28
  • [48] Incremental value of left atrial strain to predict atrial fibrillation recurrence after cryoballoon ablation
    Motoc, A.
    Luchian, M. L.
    Scheirlynck, E.
    Roosens, B.
    Chameleva, H.
    Galloo, X.
    Von Kemp, B.
    Ramak, R.
    Sieira, J.
    De Asmundis, C.
    Chierchia, G. B.
    Magne, J.
    Weytjens, C.
    Droogmans, S.
    Cosyns, B.
    EUROPEAN HEART JOURNAL, 2022, 43 : 9 - 9
  • [49] Balloon warming time is the strongest predictor of late pulmonary vein electrical reconnection following cryoballoon ablation for atrial fibrillation
    Ghosh, Justin
    Martin, Andrew
    Keech, Anthony C.
    Chan, Kim H.
    Gomes, Sean
    Singarayar, Suresh
    McGuire, Mark A.
    HEART RHYTHM, 2013, 10 (09) : 1311 - 1317
  • [50] Effect of Pulmonary Vein Anatomy and Pulmonary Vein Diameters on Outcome of Cryoballoon Catheter Ablation for Atrial Fibrillation
    Guler, Ekrem
    Guler, Gamze Babur
    Demir, Gultekin Gunhan
    Kizilirmak, Filiz
    Gunes, Haci Murat
    Barutcu, Irfan
    Kilicaslan, Fethi
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2015, 38 (08): : 989 - 996