Cryoballoon temperature parameters during cryoballoon ablation predict pulmonary vein reconnection and atrial fibrillation recurrence

被引:3
|
作者
Chahine, Yaacoub [1 ]
Afroze, Tanzina [1 ]
Bifulco, Savannah F. [2 ]
Macheret, Fima [1 ]
Abdulsalam, Nashwa [1 ]
Boyle, Patrick M. [2 ,3 ,4 ]
Akoum, Nazem [1 ,2 ]
机构
[1] Univ Washington, Div Cardiol, Seattle, WA 98195 USA
[2] Univ Washington, Dept Bioengn, 1959 NE Pacific St, Seattle, WA 98195 USA
[3] Univ Washington, Inst Stem Cell & Regenerat Med, Seattle, WA 98195 USA
[4] Univ Washington, Ctr Cardiovasc Biol, Seattle, WA 98195 USA
关键词
Atrial fibrillation; Cryoballoon ablation; Pulmonary vein reconnection; Arrhythmia recurrence; Balloon temperature; ANTIARRHYTHMIC-DRUG THERAPY; CATHETER ABLATION;
D O I
10.1007/s10840-022-01429-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Cryoballoon ablation (CBA) is an established approach for rhythm management of atrial fibrillation (AF). We sought to assess balloon temperature (BT) parameters as predictors of pulmonary vein (PV) reconnection within the index procedure and AF recurrence following CBA. Methods BT was monitored in 119 AF patients undergoing CBA. PVs were assessed for reconnection during the procedure and patients were followed for arrhythmia recurrence. Results PV reconnection was identified in 39 (8.3%) of 471 PVs. BT was significantly colder in the absence of PV reconnection (30 s: - 33.5 degrees C [- 36; - 30] vs - 29.5 degrees C [- 35; - 25.5], p = 0.001; 60 s: - 41 degrees C [- 44; - 37] vs - 36.5 degrees C [- 42; - 33.5], p < 0.001; nadir: - 47 degrees C [- 52; - 43] vs - 41.5 degrees C [- 47; - 38], p < 0.001). PV reconnection was associated with significantly longer time to reach - 15 degrees C and - 40 degrees C (14.5 s [11.5-18.5] vs 12 s [10-15.5], p = 0.023; and 75 s [40-95.5] vs 46 s [37-66.75], p = 0.005) and shorter rewarming time (5.75 s [4.75-8.5] vs 7 s [6-9], p = 0.012). ROC analysis of these procedural parameters had an AUC = 0.71 in predicting PV reconnection. AF recurrence occurred in 51 (42.8%) patients. Kaplan-Meier analysis showed better arrhythmia-free survival for patients in whom BT decreased below - 40 degrees C in all PVs and patients who had no early PV reconnections, compared to patients in whom BT below - 40 degrees C was not achieved in at least one PV (log rank = 6.3, p = 0.012) and patients who had PV reconnections (log rank = 4.1, p = 0.043). Conclusions Slower BT decline, warmer BT nadir, and faster rewarming time predict early PV reconnection. Absence of early PV reconnections and BT dropping below - 40 degrees C in all PVs during CBA are associated with lower rates of AF recurrence.
引用
收藏
页码:1367 / 1373
页数:7
相关论文
共 50 条
  • [31] Cryoballoon ablation for atrial fibrillation - is cryoenergy applied only to the pulmonary vein ostium?
    Baran, Jakub
    Lewandowski, Pawel
    Piotrowski, Roman
    Kulakowski, Piotr
    CLINICAL RESPIRATORY JOURNAL, 2018, 12 (01): : 288 - 290
  • [32] Tailored Cryoballoon Pulmonary Vein Ablation for Atrial Fibrillation: When to Stop the Freeze?
    Emami, Mehrdad
    Ariyaratnam, Jonathan P.
    Pitman, Bradley M.
    Lau, Dennis H.
    HEART LUNG AND CIRCULATION, 2022, 31 (04): : 457 - 459
  • [33] Pulmonary vein re-mapping after cryoballoon ablation for atrial fibrillation
    Yokoyama, Kenichi
    Tokuda, Michifumi
    Matsuo, Seiichiro
    Isogai, Ryota
    Tokutake, Kenichi
    Kato, Mika
    Narui, Ryohsuke
    Tanigawa, Shinichi
    Yamashita, Seigo
    Inada, Keiichi
    Yoshimura, Michihiro
    Yamane, Teiichi
    EUROPACE, 2018, 20 (06): : 943 - 948
  • [34] Pulmonary Vein Intramural Hematoma as a Complication of Cryoballoon Ablation of Paroxysmal Atrial Fibrillation
    Conte, Giulio
    Chierchia, Gian-Battista
    Casado-Arroyo, Ruben
    Ilsen, Bart
    Brugada, Pedro
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2013, 24 (07) : 830 - 831
  • [35] Earliest pulmonary vein potential-guided cryoballoon ablation for atrial fibrillation
    Mizutani, Yoshiaki
    Kanashiro, Masaaki
    Makino, Yuichiro
    Satake, Akinori
    Suzuki, Wataru
    Kurobe, Masanari
    Mizutani, Kouji
    Ichimiya, Hitoshi
    Uchida, Yasuhiro
    Watanabe, Junji
    Ichimiya, Satoshi
    Inden, Yasuya
    Murohara, Toyoaki
    HEART AND VESSELS, 2020, 35 (02) : 232 - 238
  • [36] Pulmonary Hemorrhage After Cryoballoon Ablation for Pulmonary Vein Isolation in the Treatment of Atrial Fibrillation
    Marti-Almor, Julio
    Jauregui-Abularach, Miguel E.
    Benito, Begona
    Valles, Ermengol
    Bazan, Victor
    Sanchez-Font, Albert
    Vollmer, Ivan
    Altaba, Carmen
    Guijo, Miguel A.
    Hervas, Manel
    Bruguera-Cortada, Jordi
    CHEST, 2014, 145 (01) : 156 - 157
  • [37] A novel pulmonary vein potential mimic unique to cryoballoon ablation of atrial fibrillation
    Andrade, Jason
    Mondesert, Blandine
    Dubuc, Marc
    EUROPACE, 2012, 14 (12): : 1686 - 1686
  • [38] Earliest pulmonary vein potential-guided cryoballoon ablation for atrial fibrillation
    Yoshiaki Mizutani
    Masaaki Kanashiro
    Yuichiro Makino
    Akinori Satake
    Wataru Suzuki
    Masanari Kurobe
    Kouji Mizutani
    Hitoshi Ichimiya
    Yasuhiro Uchida
    Junji Watanabe
    Satoshi Ichimiya
    Yasuya Inden
    Toyoaki Murohara
    Heart and Vessels, 2020, 35 : 232 - 238
  • [39] Cryoballoon ablation beyond pulmonary vein isolation in the setting of persistent atrial fibrillation
    Miraglia, Vincenzo
    Bisignani, Antonio
    Pannone, Luigi
    Iacopino, Saverio
    Chierchia, Gian-Battista
    de Asmundis, Carlo
    EXPERT REVIEW OF MEDICAL DEVICES, 2022, 19 (05) : 431 - 439
  • [40] Anatomical Change and Stenosis of the Pulmonary Vein After Cryoballoon Ablation for Atrial Fibrillation
    Miyama, Hiroshi
    Yamashita, Terumasa
    Fujisawa, Taishi
    Nakajima, Kazuaki
    Katsumata, Yoshinori
    Nishiyama, Takahiko
    Kimura, Takehiro
    Aizawa, Yoshiyasu
    Fukuda, Keiichi
    Takatsuki, Seji
    CIRCULATION, 2018, 138