The risk of clinical misinterpretation of HbA1c: Modelling the impact of biological variation and analytical performance on HbA1c used for diagnosis and monitoring of diabetes

被引:3
|
作者
Weykamp, Cas [1 ,2 ]
Siebelder, Carla [1 ,2 ]
Lenters, Erna [3 ,4 ]
Slingerland, Robbert [3 ,4 ]
English, Emma [5 ]
机构
[1] Streekziekenhuis Koningin Beatrix, Dept Clin Chem, Beatrixpark 1, NL-7101 BN Winterswijk, Netherlands
[2] European Reference Lab Glycohemoglobin, locat Winterswijk, Beatrixpark 1, NL-7101 BN Winterswijk, Netherlands
[3] Dept Clin Chem, Isala, Dr Heesweg 2, NL-8025 AB Zwolle, Netherlands
[4] European Reference Lab Glycohemoglobin, Locat Zwolle, Dr Heesweg 2, NL-8025 AB Zwolle, Netherlands
[5] Univ East Anglia, Fac Med & Hlth, Queens Bldg, Norwich NR4 7TJ, England
关键词
HbA1c; Clinical misinterpretation; Biological variation of HbA1c; Analytical performance; Diabetes; Non-glucose related factors contributing to the; STANDARDIZATION; ANEMIA;
D O I
10.1016/j.cca.2023.117495
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The validity of clinical interpretation of HbA1c depends on the analytical performance of the method and the biological variation of HbA1c in patients. The contribution of non-glucose related factors to the bio-logical variation of HbA1c (NGBVA1c) is not known. This paper explores the cumulative impact of analytical errors and NGBVA1c on the risk of misinterpretation.Methods: A model has been developed to predict the risk of misinterpretation of HbA1c for diagnosis and monitoring with variables for analytical performance and levels of NGBVA1c.Results: The model results in probabilities of misinterpretation for a given HbA1c. Example: for an HbA1c 43 mmol/mol (6.1%), bias 1 mmol/mol (0.09%), CV 3% (2%) used for diagnosis, the probabilities of misinter-pretation range from 1 to 19% depending on the contribution of NGBVA1c to the biological variation of HbA1c.Conclusions: In addition to analytical bias and imprecision, NGBVA1c contributes to the risk of misinterpretation, but the relative impact is different per clinical application of HbA1c. For monitoring, imprecision is the pre-dominating factor, for diagnosis both biological variation and analytical bias. Given the increasing use of HbA1c for diagnosis, increase of knowledge on NGBVA1c, decrease of analytical bias, and awareness of the risk of misinterpretation are required.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] HbA1c measurement for the diagnosis of diabetes: is it enough?
    Cavagnolli, G.
    Comerlato, J.
    Comerlato, C.
    Renz, P. B.
    Gross, J. L.
    Camargo, J. L.
    DIABETIC MEDICINE, 2011, 28 (01) : 31 - 35
  • [22] Value of HbA1c as a Criterion for Diabetes Diagnosis
    Nowotny, B.
    DIABETOLOGE, 2011, 7 (04): : 269 - 269
  • [23] HbA1c and blood glucose for the diagnosis of diabetes
    Misra, Anoop
    Garg, Satish
    LANCET, 2011, 378 (9786): : 104 - 106
  • [24] HBA1C MEASUREMENT FOR THE DIAGNOSIS OF DIABETES: IS IT ENOUGH?
    Cosma, C.
    Lapolla, A.
    Epifani, M. G.
    Artusi, C.
    Zaninotto, M.
    Plebani, M.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S375 - S375
  • [25] Is HbA1c suitable for diagnosis of diabetes? Pro
    Joost, H. -G.
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2011, 136 (21) : 1128 - 1128
  • [26] HbA1c for screening and diagnosis of diabetes mellitus
    Higgins, Trefor
    ENDOCRINE, 2013, 43 (02) : 266 - 273
  • [27] HBA1C IN THE DIAGNOSIS OF DIABETES: OPPORTUNITIES AND PROBLEMS
    Sacks, D. B.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S37 - S37
  • [28] Diagnosis and Screening for HbA1c
    不详
    WEST INDIAN MEDICAL JOURNAL, 2009, 58 : 26 - 26
  • [29] EQA: HbA1c FIT FOR THE DIAGNOSIS OF DIABETES?
    Weykamp, Cas W.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S33 - S33
  • [30] Is HbA1c suitable for diagnosis of diabetes? Contra
    Kerner, W.
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2011, 136 (21) : 1129 - 1129