The risk of clinical misinterpretation of HbA1c: Modelling the impact of biological variation and analytical performance on HbA1c used for diagnosis and monitoring of diabetes

被引:3
|
作者
Weykamp, Cas [1 ,2 ]
Siebelder, Carla [1 ,2 ]
Lenters, Erna [3 ,4 ]
Slingerland, Robbert [3 ,4 ]
English, Emma [5 ]
机构
[1] Streekziekenhuis Koningin Beatrix, Dept Clin Chem, Beatrixpark 1, NL-7101 BN Winterswijk, Netherlands
[2] European Reference Lab Glycohemoglobin, locat Winterswijk, Beatrixpark 1, NL-7101 BN Winterswijk, Netherlands
[3] Dept Clin Chem, Isala, Dr Heesweg 2, NL-8025 AB Zwolle, Netherlands
[4] European Reference Lab Glycohemoglobin, Locat Zwolle, Dr Heesweg 2, NL-8025 AB Zwolle, Netherlands
[5] Univ East Anglia, Fac Med & Hlth, Queens Bldg, Norwich NR4 7TJ, England
关键词
HbA1c; Clinical misinterpretation; Biological variation of HbA1c; Analytical performance; Diabetes; Non-glucose related factors contributing to the; STANDARDIZATION; ANEMIA;
D O I
10.1016/j.cca.2023.117495
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The validity of clinical interpretation of HbA1c depends on the analytical performance of the method and the biological variation of HbA1c in patients. The contribution of non-glucose related factors to the bio-logical variation of HbA1c (NGBVA1c) is not known. This paper explores the cumulative impact of analytical errors and NGBVA1c on the risk of misinterpretation.Methods: A model has been developed to predict the risk of misinterpretation of HbA1c for diagnosis and monitoring with variables for analytical performance and levels of NGBVA1c.Results: The model results in probabilities of misinterpretation for a given HbA1c. Example: for an HbA1c 43 mmol/mol (6.1%), bias 1 mmol/mol (0.09%), CV 3% (2%) used for diagnosis, the probabilities of misinter-pretation range from 1 to 19% depending on the contribution of NGBVA1c to the biological variation of HbA1c.Conclusions: In addition to analytical bias and imprecision, NGBVA1c contributes to the risk of misinterpretation, but the relative impact is different per clinical application of HbA1c. For monitoring, imprecision is the pre-dominating factor, for diagnosis both biological variation and analytical bias. Given the increasing use of HbA1c for diagnosis, increase of knowledge on NGBVA1c, decrease of analytical bias, and awareness of the risk of misinterpretation are required.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] HbA1c or glucose for diabetes diagnosis?
    Florkowski, CM
    Woltersdorf, WWW
    ANNALS OF CLINICAL BIOCHEMISTRY, 2005, 42 : 408 - 409
  • [2] Use of HbA1c in the diagnosis of diabetes
    Farmer, Andrew
    BMJ-BRITISH MEDICAL JOURNAL, 2012, 345
  • [3] HBA1C FOR DIABETES MELLITUS DIAGNOSIS
    Dzebisashvili, T.
    JOURNAL OF EPIDEMIOLOGY AND COMMUNITY HEALTH, 2011, 65 : A330 - A330
  • [4] Pitfalls of HbA1c in the Diagnosis of Diabetes
    Bergman, Michael
    Abdul-Ghani, Muhammad
    Neves, Joao Sergio
    Monteiro, Mariana P.
    Medina, Jose Luiz
    Dorcely, Brenda
    Buysschaert, Martin
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2020, 105 (08): : 2803 - 2811
  • [5] HbA1c or glucose for diabetes diagnosis?
    Kilpatrick, ES
    ANNALS OF CLINICAL BIOCHEMISTRY, 2005, 42 : 165 - 166
  • [6] HbA1c screening for the diagnosis of diabetes
    Jan Brož
    Marek Brabec
    Pavlína Krollová
    Lucia Fačkovcová
    Juraj Michalec
    Diabetologia, 2023, 66 : 1576 - 1577
  • [7] HbA1c in the Diagnosis and Prediction of Diabetes
    Gong, Qiuhong
    Hanson, Robert L.
    Mason, Clinton C.
    Knowler, William C.
    DIABETES, 2009, 58 : A259 - A259
  • [8] HbA1c screening for the diagnosis of diabetes
    Broz, Jan
    Brabec, Marek
    Krollova, Pavlina
    Fackovcova, Lucia
    Michalec, Juraj
    DIABETOLOGIA, 2023, 66 (08) : 1576 - 1577
  • [9] The Use of HbA1c for the Diagnosis of Diabetes
    Bonora, Enzo
    CURRENT DIABETES REPORTS, 2011, 11 (06) : 470 - 471
  • [10] HBA1C FOR DIABETES MELLITUS DIAGNOSIS
    Dzebisashvili, T.
    JOURNAL OF EPIDEMIOLOGY AND COMMUNITY HEALTH, 2011, 65 : A330 - A331