Tri-Band Inter-Frequency Group Delay Calibration

被引:0
作者
Strong, Matthew [1 ]
Miller, Jackson [1 ]
Green, Nathan [1 ]
机构
[1] LeTourneau Univ, Elect & Comp Engn, Longview, TX 75602 USA
来源
2023 IEEE/ION POSITION, LOCATION AND NAVIGATION SYMPOSIUM, PLANS | 2023年
关键词
Calibration; triple-frequency; coherent; undergraduate research; GNSS;
D O I
10.1109/PLANS53410.2023.10140115
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Triple Frequency Reference Station (TFRS) is developing circuitry and associated firmware to produce a phase-coherent signal across the L1, L2, and L5 frequency bands for calibration of triple-frequency, high-accuracy GPS receivers. As an undergraduate project, TFRS aims to assist in the calibration of ionospheric biases by enabling on-demand calibration of receivers as environmental or external factors change. The signal is generated by a Complex Programmable Logic Device (CPLD) and upconverted by three-stages of mixers, placing phase-coherent, GNSS-like signals onto L1, L2, and L5. Modifications to the GRID software defined receiver will measure inter-channel biases of the generated signal when processed by a front-end. TFRS hopes to attain a phase-coherence of 100 picoseconds or less and confirm this accuracy with a series of tests culminating in inter-channel bias measurements.
引用
收藏
页码:1033 / 1039
页数:7
相关论文
共 42 条
[31]   Calibration of Motional Frequency Spread for Wide-Band FMCW Automotive Millimeter-Wave Radar [J].
Zhang, Cheng ;
Cao, Mengde ;
Gong, Yuqin ;
Li, Yang ;
Huang, Yongming ;
Wang, Haiming .
IEEE ACCESS, 2020, 8 :14355-14366
[32]   Recent Activities and Achievements of the Global Space-based Inter-Calibration System (GSICS) Research Working Group [J].
Wu, Xiangqian ;
Goldberg, Mitch .
ATMOSPHERIC AND ENVIRONMENTAL REMOTE SENSING DATA PROCESSING AND UTILIZATION IV: READINESS FOR GEOSS II, 2008, 7085
[33]   Analysis and Inter-Calibration of Wet Path Delay Datasets to Compute the Wet Tropospheric Correction for CryoSat-2 over Ocean [J].
Joana Fernandes, M. ;
Nunes, Alexandra L. ;
Lazaro, Clara .
REMOTE SENSING, 2013, 5 (10) :4977-5005
[34]   Calculation and Matching of Correction Frequency Band in In Situ Calibration of Permanent Magnet Sodium Flowmeter Without Vortex Generator [J].
Yu, Xin-Long ;
Xu, Ke-Jun .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
[35]   A Wide Band VCO with Automatic Frequency, Gain, and Two-Step Amplitude Calibration Loop for DTV Tuner Application [J].
Pu, YoungGun ;
Lee, Kang-Yoon .
IEICE TRANSACTIONS ON ELECTRONICS, 2009, E92C (12) :1496-1503
[36]   VLBI phase-calibration system suitable for very-wide-band and ultra-high-frequency operation [J].
Kiuchi, H ;
Takahashi, Y ;
Kurihara, N ;
Ambrosini, R ;
McCulloch, PM .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1999, 48 (06) :1093-1099
[37]   High Quality Zenith Tropospheric Delay Estimation Using a Low-Cost Dual-Frequency Receiver and Relative Antenna Calibration [J].
Krietemeyer, Andreas ;
van der Marel, Hans ;
van de Giesen, Nick ;
ten Veldhuis, Marie-Claire .
REMOTE SENSING, 2020, 12 (09)
[38]   BDS-3 Triple-Frequency Timing Group Delay/Differential Code Bias and Its Effect on Positioning [J].
Du, Yanjun ;
Yang, Yuanxi ;
Jia, Xiaolin ;
Yao, Wanqiang ;
Li, Jiahao ;
Li, Qin .
REMOTE SENSING, 2023, 15 (08)
[39]   Alignment and Calibration of high frequency ultrasound (HFUS) and optical coherence tomography (OCT) 1D transducers using a dual wedge-tri step phantom [J].
Afsham, N. ;
Chan, K. ;
Pan, L. ;
Tang, S. ;
Rohling, R. N. .
MEDICAL IMAGING 2011: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2011, 7964
[40]   A Digital Frequency-Dependent I/Q Imbalance and Group Delay Estimation and Compensation Modules for mmWave Single Carrier Baseband Transceivers [J].
Jen, Chih-Wei ;
Liu, Hung-Chih ;
Huang, Zheng-Chun ;
Xue, Nai-Cheng ;
Jou, Shyh-Jye Jerry .
IEEE JOURNAL ON EMERGING AND SELECTED TOPICS IN CIRCUITS AND SYSTEMS, 2023, 13 (02) :461-475