Chemometrics Assisted Spectrophotometric Method Development and Validation for Simultaneous Estimation of Abacavir, Lamivudine and Dolutegravir in Dosage Form

被引:0
作者
Rathod, Sapna [1 ,4 ]
Patel, Paresh [2 ]
Patel, Nisarg [3 ]
机构
[1] APMC Coll Pharmaceut Educ & Res, Dept Pharmaceut Chem & Qual Assurance, Himatnagar, Gujarat, India
[2] Ganpat Univ, SK Patel Coll Pharmaceut Educ & Res, Dept Pharmaceut Chem & Qual Assurance, Kherva, Gujarat, India
[3] APMC Coll Pharmaceut Educ & Res, Dept Pharmacognosy, Himatnagar, Gujarat, India
[4] APMC Coll Pharmaceut Educ & Res, Dept Pharmaceut Chem & Qual Assurance, Himatnagar 383001, Gujarat, India
关键词
Abacavir sulphate; Lamivudine; Dolutegravir sodium; Chemometrics; Spectophotometric; Validation; CHROMATOGRAPHY; DESIGN;
D O I
10.5530/ijper.57.2.70
中图分类号
G40 [教育学];
学科分类号
040101 ; 120403 ;
摘要
Aim: Multivariate methods, particularly Classical Least Square, Inverse Least Square (ILS), Partial Least Square and Principal Component Regression are invented for the quantitation of the Abacavir sulphate (ABA), Lamivudine (LAM) and Dolutegravir sodium (DOL) in their combined tablet formulation. Materials and Methods: Chemometrics is the integration of statistical and mathematical approaches to analytical data in order to extract as much information as possible. The calibration and validation sets were built using fractional factorial design. 32 ternary mixtures of calibration sets and 16 mixtures of validation set were prepared. The absorbance data matrix was created by measuring absorbance in the range of 230 to 308 nm (Delta lambda = 3 nm) at 27 distinct wavelengths. The models were developed with the aid of MATLAB 2018a, Minitab 16.1.1 and MS Excel 2010. Results: The recovery values were close to 100% with low standard deviation (SD) justified the high accuracy of the proposed methods. For chemometrics approaches, the RMSECV, RMSEC, and RMSEP values produced show good accuracy and precision. The values of model diagnostic tools were lowest for ILS method. Conclusion: The ILS was shown to be the most appropriate method among produced chemometric models. The chemometric method is more accurate and precise than conventional methods as the total absorbance of the ternary mixture was measured and can be utilised in simultaneous estimation. With great recoveries and precision, the proposed approach was successfully used to the assay of formulation.
引用
收藏
页码:570 / 582
页数:13
相关论文
共 28 条
[1]  
[Anonymous], 1998, Chemometrics: A Practical Guide
[2]  
[Anonymous], 2005, TECHN REQ REG PHARM, VQ2
[3]  
Balasaheb B.G., 2015, MALAYS J ANAL SCI, V19, P1156
[4]   Factorial Design for Development of a High-Performance Thin-Layer Chromatography Method for the Simultaneous Estimation of Abacavir Sulfate, Lamivudine Hydrochloride, and Dolutegravir Sodium [J].
Dave, Krupali ;
Desai, Sonal .
JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2018, 31 (06) :489-495
[5]   UV Spectrophotometric Method for Assay of the Anti-Retroviral Agent Lamivudine in Active Pharmaceutical Ingredient and in its Tablet Formulation [J].
Deepali, G. ;
Elvis, M. .
JOURNAL OF YOUNG PHARMACISTS, 2010, 2 (04) :417-419
[6]  
Dubey S., 2018, Int. J. App. Pharm, V10, P46, DOI 10.22159/ijap.2018v10i1.21156
[7]   Simultaneous determination of rifampicin, isoniazid and pyrazinamide in tablet preparations by multivariate spectrophotometric calibration [J].
Goicoechea, HC ;
Olivieri, AC .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 20 (04) :681-686
[8]  
Howland RD, 2007, LIPPINCOTTS ILLUSTRA, V1st
[9]  
Khaleel N, 2015, WORLD J PHARM RES, V4, P1453
[10]  
Kramer R., 1998, CHEMOMETRIC TECHNIQU