Effect of high-speed sintering on the marginal and internal fit of CAD/CAM-fabricated monolithic zirconia crowns

被引:2
|
作者
Lee, Seulgi [1 ]
Choi, Gyujin [2 ]
Choi, Jinhyeok [2 ]
Kim, Youngjun [2 ]
Kim, Hee-Kyung [3 ]
机构
[1] Ajou Univ, Grad Sch Clin Dent, Dept Dent Publ Hlth, Suwon, South Korea
[2] Imagoworks Inc, Seoul, South Korea
[3] Ajou Univ, Inst Oral Hlth Sci, Dept Prosthodont, Sch Med, Suwon, South Korea
来源
SCIENTIFIC REPORTS | 2023年 / 13卷 / 01期
基金
新加坡国家研究基金会;
关键词
CERAMICS;
D O I
10.1038/s41598-023-44587-5
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study compared the marginal and internal fit of zirconia crowns fabricated using conventional and high-speed induction sintering. A typodont mandibular right first molar was prepared and 60 zirconia crowns were fabricated: 30 crowns using conventional sintering and 30 crowns using high-speed sintering. We presented a new evaluation methodology to measure the marginal and internal fit of restorations through digital scanning, aligning the two datasets, and measuring the distance between two arbitrary point sets of the datasets. For the marginal fit, we calculated the maximum values of the shortest distances between the marginal line of the prepared tooth and that of the crown. The calculated values ranged from 359 to 444 mu m, with smaller values for the high-speed sintered crowns (P<0.05). For the internal fit, we employed mesh sampling and computed the geodesic distances between the prepared tooth surface and the crown intaglio surface. The measured values ranged from 177 to 229 mu m with smaller values for the high-speed sintered crowns, but no significant difference was found (P>0.05). Based on our results, the high-speed sintering method can be considered a promising option for single-visit zirconia treatment in dental practice.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Effect of high-speed sintering on the marginal and internal fit of CAD/CAM-fabricated monolithic zirconia crowns
    Seulgi Lee
    Gyujin Choi
    Jinhyeok Choi
    Youngjun Kim
    Hee-Kyung Kim
    Scientific Reports, 13 (1)
  • [2] Effect of sintering on the marginal and internal fit of CAD/CAM-fabricated zirconia frameworks
    Kunii, Jun
    Hotta, Yasuhiro
    Tamaki, Yukimichi
    Ozawa, Atushl
    Kobayashi, Yukitaka
    Fujishima, Akihiro
    Miyazaki, Takashi
    Fujiwara, Toshihisa
    DENTAL MATERIALS JOURNAL, 2007, 26 (06) : 820 - 826
  • [3] Effect of cement space on the marginal fit of CAD-CAM-fabricated monolithic zirconia crowns
    Kale, Ediz
    Seker, Emre
    Yilmaz, Burak
    Ozcelik, Tuncer Burak
    JOURNAL OF PROSTHETIC DENTISTRY, 2016, 116 (06): : 890 - 895
  • [4] Influence of preparation angle on marginal and internal fit of CAD/CAM-fabricated zirconia crown copings
    Beuer, Florian
    Aggstaller, Hans
    Richter, Juliane
    Edelhoff, Daniel
    Gernet, Wolfgang
    QUINTESSENCE INTERNATIONAL, 2009, 40 (03): : 243 - 250
  • [5] Marginal and Internal Fit of Monolithic Zirconia Crowns Fabricated by Using Two Different CAD-CAM Workflows: An In Vitro Study
    Cin, Vahap
    Izgi, Ayca Deniz
    Kale, Ediz
    Yilmaz, Burak
    PROSTHESIS, 2023, 5 (01): : 35 - 47
  • [6] Effect of fabrication stages and cementation on the marginal fit of CAD-CAM monolithic zirconia crowns
    Kale, Ediz
    Yilmaz, Burak
    Seker, Emre
    Ozcelik, Tuncer Burak
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 118 (06): : 736 - 741
  • [7] Marginal fit of CAD-CAM monolithic zirconia crowns fabricated by using cone beam computed tomography scans
    Kale, Ediz
    Cilli, Mesutcan
    Ozcelik, Tuncer Burak
    Yilmaz, Burak
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (05): : 731 - 737
  • [8] Marginal and Internal Fit of CAD/CAM Crowns Fabricated Over Reverse Tapered Preparations
    Mejia, Jeison B. Carbajal
    Yatani, Hirofumi
    Wakabayashi, Kazumichi
    Nakamura, Takashi
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (02): : E477 - E484
  • [9] Clinical Marginal and Internal Fit of Crowns Fabricated Using Different CAD/CAM Technologies
    Huang, Zhuoli
    Zhang, Lu
    Zhu, Jingwei
    Zhao, Yiwei
    Zhang, Xiuyin
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2015, 24 (04): : 291 - 295
  • [10] Effect of cementation and aging on the marginal fit of veneered and monolithic zirconia and metal-ceramic CAD-CAM crowns
    Del Pinal, Maria
    Lopez-Suarez, Carlos
    Bartolome, Jose F.
    Volpato, Claudia AM.
    Suarez, Maria J.
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (02): : 323.e1 - 323.e7