Highly cross-linked polyethylene versus conventional polyethylene in primary total knee arthroplasty: comparable clinical and radiological results at a 10-year follow-up

被引:18
作者
Giustra, Fortunato [1 ]
Bistolfi, Alessandro [2 ]
Bosco, Francesco [1 ]
Fresia, Nicolo [1 ]
Sabatini, Luigi [1 ]
Berchialla, Paola [3 ]
Sciannameo, Veronica [3 ]
Masse, Alessandro [1 ]
机构
[1] Univ Turin, Dept Orthopaed & Traumatol, CTO, Via Zuretti 29, I-10126 Turin, Italy
[2] Osped Cardinal Massaia Asti, Orthopaed & Traumatol, Via Conte Verde 125, I-14100 Asti, Italy
[3] Univ Turin, Dept Clin & Biol Sci, Turin, Italy
关键词
Polyethylene; CPE; HXLPE; Crosslinked; Knee; Total knee arthroplasty; Retrospective; PERFORMANCE; REPLACEMENT; OSTEOLYSIS; SURVIVAL; HIP;
D O I
10.1007/s00167-022-07226-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Highly crosslinked polyethylene (HXLPE) was introduced in total knee arthroplasty (TKA) to reduce wear and consequent revisions for loosening due to conventional polyethylene (CPE) wear. This study aims to analyse whether HXLPE is as safe as CPE and could improve the TKA clinical and radiological results in a long-term follow-up. Methods This retrospective study included all consecutive starting series of 223 patients with severe primary knee osteoarthritis (OA), with a minimum follow-up of 10 years treated between July 1st, 2007, and July 31st, 2010. After excluding patients who did not respect the inclusion and exclusion criteria, 128 patients were included in the analysis of this study. The patients were then divided into two groups according to the type of polyethylene (PE) implanted: CPE or HXLPE liners. All patients were evaluated for clinical and radiological parameters, causes and revision rates related to the type of PE implanted. Results HXLPE appears to be as safe as CPE in TKA, reporting no higher revisions for osteolysis, prosthesis loosening, infection, and mechanical failure. Nevertheless, no statistically significant differences were found between the two groups in the clinical and radiological outcomes evaluated. Conclusions Clinical, radiological results, and revision rates are similar between HXLPE and CPE in TKA after 10 years of follow-up, although HXLPE benefits remain controversial.
引用
收藏
页码:1082 / 1088
页数:7
相关论文
共 30 条
[1]   Comparable results between crosslinked polyethylene and conventional ultra-high molecular weight polyethylene implanted in total knee arthroplasty: systematic review and meta-analysis of randomised clinical trials [J].
Bistolfi, Alessandro ;
Giustra, Fortunato ;
Bosco, Francesco ;
Faccenda, Carlotta ;
Viotto, Marianna ;
Sabatini, Luigi ;
Berchialla, Paola ;
Sciannameo, Veronica ;
Graziano, Eugenio ;
Masse, Alessandro .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2022, 30 (09) :3120-3130
[2]   Ultra-high molecular weight polyethylene (UHMWPE) for hip and knee arthroplasty: The present and the future [J].
Bistolfi, Alessandro ;
Giustra, Fortunato ;
Bosco, Francesco ;
Sabatini, Luigi ;
Aprato, Alessandro ;
Bracco, Pierangiola ;
Bellare, Anuj .
JOURNAL OF ORTHOPAEDICS, 2021, 25 :98-106
[3]   NexGenA® LPS mobile bearing total knee arthroplasty: 10-year results [J].
Bistolfi, Alessandro ;
Lee, Gwo-Chin ;
Deledda, Davide ;
Rosso, Federica ;
Berchialla, Paola ;
Crova, Maurizio ;
Massazza, Giuseppe .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (08) :1786-1792
[4]   The relative effects of radiation crosslinking and type of counterface on the wear resistance of ultrahigh-molecular-weight polyethylene [J].
Bistolfi, Alessandro ;
Bellare, Anuj .
ACTA BIOMATERIALIA, 2011, 7 (09) :3398-3403
[5]   The use of highly crosslinked polyethylene in total knee arthroplasty [J].
Brown, T. S. ;
Van Citters, D. W. ;
Berry, D. J. ;
Abdel, M. P. .
BONE & JOINT JOURNAL, 2017, 99B (08) :996-1002
[6]  
Cheppalli, 2021, CUREUS J MED SCIENCE, V13
[7]   How long does a hip replacement last? A systematic review and meta-analysis of case series and national registry reports with more than 15 years of follow-up [J].
Evans, Jonathan T. ;
Evans, Jonathan P. ;
Walker, Robert W. ;
Blom, Ashley W. ;
Whitehouse, Michael R. ;
Sayers, Adrian .
LANCET, 2019, 393 (10172) :647-654
[8]   Highly cross-linked polyethylene in primary total knee arthroplasty is associated with a lower rate of revision for aseptic loosening: a meta-analysis of 962,467 cases [J].
Gkiatas, Ioannis ;
Karasavvidis, Theofilos ;
Sharma, Abhinav K. ;
Xiang, William ;
Malahias, Michael-Alexander ;
Chalmers, Brian P. ;
Sculco, Peter K. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2022, 142 (06) :1177-1184
[9]   The Effect of Oxidative Aging on the Wear Performance of Highly Crosslinked Polyethylene Knee Inserts under Conditions of Severe Malalignment [J].
Hermida, Juan C. ;
Fischler, Andrew ;
Colwell, Clifford W., Jr. ;
D'Lima, Darryl D. .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2008, 26 (12) :1585-1590
[10]   In Vivo Comparison of Wear Particles Between Highly Crosslinked Polyethylene and Conventional Polyethylene in the Same Design of Total Knee Arthroplasties [J].
Iwakiri, Kentaro ;
Minoda, Yukihide ;
Kobayashi, Akio ;
Sugama, Ryo ;
Iwaki, Hiroyoshi ;
Inori, Fumiaki ;
Hashimoto, Yusuke ;
Ohashi, Hirotsugu ;
Ohta, Yoichi ;
Fukunaga, Kenji ;
Takaoka, Kunio .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2009, 91B (02) :799-804