Force-velocity profiling in ice hockey skating: reliability and validity of a simple, low-cost field method

被引:21
|
作者
Stenroth, Lauri [1 ]
Vartiainen, Paavo [1 ]
Karjalainen, Pasi A. [1 ]
机构
[1] Univ Eastern Finland, Dept Appl Phys, Kuopio, Finland
关键词
Power; acceleration; speed; sprint; measurement error; PERFORMANCE;
D O I
10.1080/14763141.2020.1770321
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In recent years, a simple method for force-velocity (F-v) profiling, based on split times, has emerged as a potential tool to examine mechanical variables underlying running sprint performance in field conditions. In this study, the reliability and concurrent validity of F-v profiling based on split times were examined when used for ice hockey skating. It was also tested how a modification of the method, in which the start instant of the sprint is estimated based on optimisation (time shift method), affects the reliability and validity of the method. Both intra- and inter-rater reliability were markedly improved when using the time shift method (approximately 50% decrease in the standard error of measurement). Moreover, the results calculated using the time shift method highly correlated (r > 0.83 for all variables) with the results calculated from a continuously tracked movement of the athlete, which was considered here as the reference method. This study shows that a modification to the previously published simple method for F-v profiling improves intra- and inter-rater reliability of the method in ice hockey skating. The time shift method tested here can be used as a reliable tool to test a player's physical performance characteristic underlying sprint performance in ice hockey skating.
引用
收藏
页码:874 / 889
页数:16
相关论文
共 21 条
  • [11] Validity and Reliability of a Simple, Low-Cost Measure to Quantify Children's Dietary Intake in Afterschool Settings
    Kenney, Erica L.
    Davison, Kirsten K.
    Austin, S. Bryn
    Giles, Catherine M.
    Cradock, Angie L.
    Lee, Rebekka M.
    Gortmaker, Steven L.
    JOURNAL OF THE ACADEMY OF NUTRITION AND DIETETICS, 2015, 115 (03) : 426 - 432
  • [12] Validity and Reliability of A New Low-Cost Linear Position Transducer to Measure Mean Propulsive Velocity: The ADR device
    Lopez-Torres, Olga
    Emilio Fernandez-Elias, Valentin
    Li, Jiaxin
    Angel Gomez-Ruano, Miguel
    Guadalupe-Grau, Amelia
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART P-JOURNAL OF SPORTS ENGINEERING AND TECHNOLOGY, 2022,
  • [13] Validity and intra-session reliability of a low-cost device for assessing isometric mid-thigh pull force
    Couto, Diego
    Cunha, Rafael
    Lage, Victor
    Rocha Jr, Valdinar
    Santos, Wanderson
    Ferreira Jr, Joao B.
    Tufano, James
    Vieira, Amilton
    HUMAN MOVEMENT, 2023, 24 (02) : 52 - 58
  • [14] Reliability and validity of a low-cost, wireless sensor and smartphone app for measuring force during isometric and dynamic resistance exercises
    Illera-Dominguez, Victor
    Albesa-Albiol, Lluis
    Castizo-Olier, Jorge
    Garcia-Fresneda, Adrian
    Busca, Bernat
    Ramirez-Lopez, Carlos
    Fernandez-Valdes, Bruno
    PLOS ONE, 2024, 19 (03):
  • [15] Concurrent validity, inter-unit reliability and biological variability of a low-cost pocket radar for ball velocity measurement in soccer and tennis
    Hernandez-Belmonte, Alejandro
    Sanchez-Pay, Alejandro
    JOURNAL OF SPORTS SCIENCES, 2021, 39 (12) : 1312 - 1319
  • [16] Assessing the Validity and Reliability of A Low-Cost Microcontroller-Based Load Cell Amplifier for Measuring Lower Limb and Upper Limb Muscular Force
    Gaudet, Julie
    Handrigan, Grant
    SENSORS, 2020, 20 (17) : 1 - 18
  • [17] THE CONCURRENT VALIDITY AND RELIABILITY OF A LOW-COST, HIGH-SPEED CAMERA-BASED METHOD FOR MEASURING THE FLIGHT TIME OF VERTICAL JUMPS
    Balsalobre-Fernandez, Carlos
    Tejero-Gonzalez, Carlos M.
    del Campo-Vecino, Juan
    Bavaresco, Nicolas
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2014, 28 (02) : 528 - 533
  • [18] Validity and Test-Retest Reliability of a Novel Push Low-Cost Hand-Held Dynamometer for Knee Strength Assessment during Different Force Ranges
    Macedo, Maria de Cassia
    Souza, Matheus Almeida
    Ferreira, Kariny Realino
    Campos, Laura Oliveira
    Souza, Igor Sergio Oliveira
    Barbosa, Michelle Almeida
    Brito, Ciro Jose
    Intelangelo, Leonardo
    Barbosa, Alexandre Carvalho
    DIAGNOSTICS, 2022, 12 (01)
  • [19] Salt drying: a low-cost, simple and efficient method for storing plants in the field and preserving biological repositories for DNA diversity research
    Carrio, Elena
    Rossello, Josep A.
    MOLECULAR ECOLOGY RESOURCES, 2014, 14 (02) : 344 - 351
  • [20] A simple, low-cost and rapid contrasting method for screening the particle size and monodispersity of silica microparticles by optical bright field microscopy
    Schetter, Bernd
    Fischer, Gerd
    JOURNAL OF SOL-GEL SCIENCE AND TECHNOLOGY, 2007, 44 (02) : 167 - 170