Evaluating the Performance of Verofilcon A Daily Disposable Contact Lenses in a Group of Heavy Digital Device Users

被引:1
作者
Schulze, Marc-Matthias [1 ]
Fadel, Daddi [1 ]
Luensmann, Doerte [1 ]
Ng, Alison [1 ]
Guthrie, Sarah [1 ]
Woods, Jill [1 ]
Jones, Lyndon [1 ]
机构
[1] Univ Waterloo, Ctr Ocular Res & Educ CORE, Waterloo, ON, Canada
来源
CLINICAL OPHTHALMOLOGY | 2023年 / 17卷
关键词
digital device; vision; comfort; verofilcon A; lens wettability; contact lenses; TFOS INTERNATIONAL WORKSHOP; SILICONE HYDROGEL; BLINK RATE; DISCOMFORT; SYMPTOMS; VISION; SCREEN;
D O I
10.2147/OPTH.S429250
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The purpose of this study was to evaluate the performance of verofilcon A daily disposable contact lenses (CL) in CL wearers who identified themselves as heavy digital device users. Patients and methods: This prospective, non-masked, open-label study enrolled CL wearers who reported >= 6 hours digital device use per day. Participants were dispensed with the verofilcon A study lenses for 14 +/- 2 days, to be worn for at least 5 days a week and 10 hours per day, while continuing their normal routine of digital device use. Participants rated the lens performance at the Day 14 visit using a 0-100 (with 100 being best) scale. Ratings were completed at lens insertion, after 6 hours of digital device use, just before CL removal and for overall experience. Participants also completed a 4-point (strongly agree/disagree, slightly agree/disagree) Likert scale-based questionnaire. Results: Thirty-two participants were eligible and completed the study (27 females; age 25.8 +/- 6.0 years, ranging from 19 to 40). Overall lens performance ratings at the Day 14 visit (mean +/- standard deviation) for comfort, dryness, and clarity of vision were 91 +/- 11, 88 +/- 11, and 92 +/- 9, respectively. Subjective ratings were stable throughout the day with no significant differences after insertion, after 6 hours of digital device use and before CL removal (all p>0.05). The majority of participants agreed that the study lenses performed well, provided good all-day comfort (28/32; p<0.01) and good all-day vision (29/32; p<0.01). Participants also agreed that after >= 6 hours of digital device use they were satisfied with CL comfort (27/32; p<0.01), vision (29/32; p<0.01) and that the lenses provided good performance (26/32; p<0.01). Conclusion: Verofilcon A lenses were found to perform well, with high ratings for comfort, dryness and vision that remained high throughout the day, during extensive digital device use.
引用
收藏
页码:3165 / 3176
页数:12
相关论文
共 43 条
[1]  
Abusharha AA, 2017, CLIN OPTOM, V9, P133, DOI 10.2147/OPTO.S142718
[2]   The Relationship Between Dry Eye Disease and Digital Screen Use [J].
Al-Mohtaseb, Zaina ;
Schachter, Scott ;
Lee, Bridgitte Shen ;
Garlich, Jaclyn ;
Trattler, William .
CLINICAL OPHTHALMOLOGY, 2021, 15 :3811-3820
[3]   Responses of contact lens wearers to a dry eye survey [J].
Begley, CG ;
Caffery, B ;
Nichols, KK ;
Chalmers, R .
OPTOMETRY AND VISION SCIENCE, 2000, 77 (01) :40-46
[4]   Effects of transient blur and VDT screen luminance changes on eyeblink rate [J].
Cardona, Genis ;
Gomez, Marcelo ;
Quevedo, Lluisa ;
Gispets, Joan .
CONTACT LENS & ANTERIOR EYE, 2014, 37 (05) :363-367
[5]   Blink Rate, Blink Amplitude, and Tear Film Integrity during Dynamic Visual Display Terminal Tasks [J].
Cardona, Genis ;
Garcia, Carles ;
Seres, Carme ;
Vilaseca, Meritxell ;
Gispets, Joan .
CURRENT EYE RESEARCH, 2011, 36 (03) :190-197
[6]   Improving contact-lens related dryness symptoms with silicone hydrogel lenses [J].
Chalmers, Robin ;
Long, Bill ;
Dillehay, Sally ;
Begley, Carolyn .
OPTOMETRY AND VISION SCIENCE, 2008, 85 (08) :778-784
[7]   Blink Patterns: Reading from a Computer Screen versus Hard Copy [J].
Chu, Christina A. ;
Rosenfield, Mark ;
Portello, Joan K. .
OPTOMETRY AND VISION SCIENCE, 2014, 91 (03) :297-302
[8]   Management of digital eye strain [J].
Coles-Brennan, Chantal ;
Sulley, Anna ;
Young, Graeme .
CLINICAL AND EXPERIMENTAL OPTOMETRY, 2019, 102 (01) :18-29
[9]   Risk Behaviors for Contact Lens-Related Eye Infections Among Adults and Adolescents - United States, 2016 [J].
Cope, Jennifer R. ;
Collier, Sarah A. ;
Nethercut, Hannah ;
Jones, Jefferson M. ;
Yates, Kirsten ;
Yoder, Jonathan S. .
MMWR-MORBIDITY AND MORTALITY WEEKLY REPORT, 2017, 66 (32) :841-845
[10]   The TFOS International Workshop on Contact Lens Discomfort: Report of the Subcommittee on Epidemiology [J].
Dumbleton, Kathy ;
Caffery, Barbara ;
Dogru, Murat ;
Hickson-Curran, Sheila ;
Kern, Jami ;
Kojima, Takashi ;
Morgan, Philip B. ;
Purslow, Christine ;
Robertson, Danielle M. ;
Nelson, J. Daniel .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (11) :20-36