Multidimensional analysis and performance prediction of heavy-duty gas turbine based on actual operational data

被引:9
作者
Guan, Jin [1 ]
Wang, Xusheng [1 ]
Lv, Xiaojing [2 ]
Weng, Yiwu [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Mech Engn, Key Lab Power Machinery & Engn, Minist Educ, Shanghai 200240, Peoples R China
[2] Shanghai Jiao Tong Univ, China UK Low Carbon Coll, Shanghai 201306, Peoples R China
关键词
Heavy-duty Gas turbine; Multidimensional analysis; Data-driven model; Performance prediction; Compressor surge; THERMODYNAMIC MODEL; COMBINED-CYCLE; SIMULATION; DIAGNOSTICS;
D O I
10.1016/j.applthermaleng.2023.121280
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study aims to analyze and predict the degradation, safety and operational performance of a heavy-duty gas turbine based on actual operational data after running for a long time. The dataset consists of 288,039 operational records from the Ban Shan Power Plant. The data is screened using Pearson correlation coefficients and 2means clustering. Then, efficiency degradation of compressor and gas turbine is conducted by decoupling operation state from degradation. Next, Long short-term memory(LSTM) is employed to build data-driven Tmodel based on algorithm structure similarity. Meanwhile, the safety requirements containing the compressor surge and turbine inlet temperature boundary are determined, which are considered in operational performance analysis. Results show that abnormal operation data is identified during operational times 37, 38, 39, 40, 41, 42, and 248. After 254,341 minutes, the compressor efficiency degrades nearly 1%. The surge margin of a compressor is a binary function of the corrected air mass flow and inlet guide vane (IGV). The pressure ratio of the working margin moves downward by 0.11 for each 1 degrees increase in IGV. What's more, the T-model demonstrates high accuracy and can predict operational performance at high environmental temperatures, with the accuracy of turbine outlet temperature within 0.995. The unit is particularly sensitive to IGV, natural gas flow mass, compressor inlet temperature, and turbine outlet gauge pressure. When the relative humidity is 68%, the electrical power is the highest and overall efficiency is the best. Overall, this study's approach has significant potential for multidimensional analysis and performance prediction.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Concise Estimation Model of Thermodynamic Performance for Bottom Cycle of F/G/H-class Heavy Duty Gas Turbine Combined Cycle
    Huang C.
    Wang B.
    Zhang S.
    Zhao L.
    Xiao Y.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2019, 39 (21): : 6320 - 6327
  • [42] Thermodynamic analysis and parametric optimization of CDTPC-ARC based on cascade use of waste heat of heavy-duty internal combustion engines (ICEs)
    Wu, Chuang
    Wang, Shun-sen
    Bai, Kun-lun
    Li, Jun
    APPLIED THERMAL ENGINEERING, 2016, 106 : 661 - 673
  • [43] Student Behavior Analysis and Performance Prediction Based on Blended Learning Data
    Chen, Juan
    Fan, Fengrui
    Jia, Haiyang
    Xu, Yuanteng
    Dong, Hanchen
    Huang, Xiaopai
    Li, Jianyu
    Zhang, Zhongrui
    KNOWLEDGE SCIENCE, ENGINEERING AND MANAGEMENT, PT II, 2022, 13369 : 597 - 609
  • [44] Performance prediction of an internal-circulation membrane bioreactor based on models comparison and data features analysis
    Zhuang, Lipeng
    Tang, Bing
    Bin, Liying
    Li, Ping
    Huang, Shaosong
    Fu, Fenglian
    BIOCHEMICAL ENGINEERING JOURNAL, 2021, 166
  • [45] Research on load prediction of low-calorific fuel fired gas turbine based on data and knowledge hybrid model
    Xin, Xiaopeng
    Chen, Pei
    Liu, Hui
    Sa, Guodong
    Hou, Mingjie
    Liu, Zhenyu
    Tan, Jianrong
    APPLIED THERMAL ENGINEERING, 2024, 253
  • [46] More realistic degradation trend prediction for gas turbine based on factor analysis and multiple penalty mechanism loss function
    Zhou, Zhihao
    Zhang, Wei
    Yao, Peng
    Long, Zhenhua
    Bai, Mingling
    Liu, Jinfu
    Yu, Daren
    RELIABILITY ENGINEERING & SYSTEM SAFETY, 2024, 247
  • [47] Performance prediction of gas turbine blade with multi-source random factors using active learning-based neural network
    Qiu, Zhilong
    Wang, Yuqi
    Li, Jinxing
    Xie, Yonghui
    Zhang, Di
    APPLIED THERMAL ENGINEERING, 2024, 242
  • [48] Exergy based performance analysis of a solid oxide fuel cell and steam injected gas turbine hybrid power system
    Motahar, Sadegh
    Alemrajabi, Ali Akbar
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2009, 34 (05) : 2396 - 2407
  • [49] The investigation of an SGT5-2000E gas turbine power plant performance in Benin City based on energy analysis
    Egware, H. O.
    Obanor, A. I.
    ENERGY CONVERSION AND MANAGEMENT-X, 2022, 16
  • [50] Performance prediction of gasification-integrated solid oxide fuel cell and gas turbine cogeneration system based on PSO-BP neural network
    Wu, Xiao-long
    Yang, Yuxiao
    Li, Keye
    Xu, Yuan-wu
    Peng, Jingxuan
    Chi, Bo
    Wang, Zhuo
    Li, Xi
    RENEWABLE ENERGY, 2024, 237