Multidimensional analysis and performance prediction of heavy-duty gas turbine based on actual operational data

被引:11
作者
Guan, Jin [1 ]
Wang, Xusheng [1 ]
Lv, Xiaojing [2 ]
Weng, Yiwu [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Mech Engn, Key Lab Power Machinery & Engn, Minist Educ, Shanghai 200240, Peoples R China
[2] Shanghai Jiao Tong Univ, China UK Low Carbon Coll, Shanghai 201306, Peoples R China
关键词
Heavy-duty Gas turbine; Multidimensional analysis; Data-driven model; Performance prediction; Compressor surge; THERMODYNAMIC MODEL; COMBINED-CYCLE; SIMULATION; DIAGNOSTICS;
D O I
10.1016/j.applthermaleng.2023.121280
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study aims to analyze and predict the degradation, safety and operational performance of a heavy-duty gas turbine based on actual operational data after running for a long time. The dataset consists of 288,039 operational records from the Ban Shan Power Plant. The data is screened using Pearson correlation coefficients and 2means clustering. Then, efficiency degradation of compressor and gas turbine is conducted by decoupling operation state from degradation. Next, Long short-term memory(LSTM) is employed to build data-driven Tmodel based on algorithm structure similarity. Meanwhile, the safety requirements containing the compressor surge and turbine inlet temperature boundary are determined, which are considered in operational performance analysis. Results show that abnormal operation data is identified during operational times 37, 38, 39, 40, 41, 42, and 248. After 254,341 minutes, the compressor efficiency degrades nearly 1%. The surge margin of a compressor is a binary function of the corrected air mass flow and inlet guide vane (IGV). The pressure ratio of the working margin moves downward by 0.11 for each 1 degrees increase in IGV. What's more, the T-model demonstrates high accuracy and can predict operational performance at high environmental temperatures, with the accuracy of turbine outlet temperature within 0.995. The unit is particularly sensitive to IGV, natural gas flow mass, compressor inlet temperature, and turbine outlet gauge pressure. When the relative humidity is 68%, the electrical power is the highest and overall efficiency is the best. Overall, this study's approach has significant potential for multidimensional analysis and performance prediction.
引用
收藏
页数:15
相关论文
共 45 条
[1]   Fault diagnosis of an industrial gas turbine based on the thermodynamic model coupled with a multi feedforward artificial neural networks [J].
Alblawi, Adel .
ENERGY REPORTS, 2020, 6 :1083-1096
[2]  
Alger M., 2021, Chem. Eng. Sci.: X, V10
[3]   Thermodynamic modeling and parametric study of a small-scale natural gas/hydrogen-fueled gas turbine system for decentralized applications [J].
Arsalis, Alexandros .
SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2019, 36
[4]   NARX models for simulation of the start-up operation of a single-shaft gas turbine [J].
Asgari, Hamid ;
Chen, XiaoQi ;
Morini, Mirko ;
Pinelli, Michele ;
Sainudiin, Raazesh ;
Spina, Pier Ruggero ;
Venturini, Mauro .
APPLIED THERMAL ENGINEERING, 2016, 93 :368-376
[5]  
Balevic D., 2010, Heavy Duty Gas Turbine Operating and Maintenance Considerations
[6]   Application of artificial neural networks to micro gas turbines [J].
Bartolini, C. M. ;
Caresana, F. ;
Comodi, G. ;
Pelagalli, L. ;
Renzi, M. ;
Vagni, S. .
ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (01) :781-788
[7]  
Brooks F.J., 2000, GE Gas Turbine Performance Characteristics
[8]   Real time simulation of medium size gas turbines [J].
Chacartegui, R. ;
Sanchez, D. ;
Munoz, A. ;
Sanchez, T. .
ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (01) :713-724
[9]   A simulation model for transient behaviour of heavy-duty gas turbines [J].
Chaibakhsh, Ali ;
Amirkhani, Saeed .
APPLIED THERMAL ENGINEERING, 2018, 132 :115-127
[10]   Nonlinear modeling of regenerative cycle micro gas turbine [J].
Duan, Jiandong ;
Sun, Li ;
Wang, Guanglin ;
Wu, Fengjiang .
ENERGY, 2015, 91 :168-175