Relative motion between the flexor digitorum superficialis tendon and subsynovial connective tissue is time dependent

被引:3
|
作者
Kociolek, Aaron M. [1 ]
Keir, Peter J. [2 ,3 ]
机构
[1] Nipissing Univ, Sch Phys & Hlth Educ, North Bay, ON, Canada
[2] McMaster Univ, Dept Kinesiol, Occupat Biomech Lab, Hamilton, ON, Canada
[3] Mc Master Univ, Dept Kinesiol, 1280 Main St West, Hamilton, ON L8S 4K1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
carpal tunnel; shear; strain; ultrasound; viscoelastic; CARPAL-TUNNEL-SYNDROME; LONGITUDINAL MEDIAN NERVE; GLIDING CHARACTERISTICS; PATHOLOGICAL-CHANGES; DISPLACEMENT; EXPOSURE; VELOCITY; STRAIN; WRIST; TENOSYNOVIUM;
D O I
10.1002/jor.25524
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The subsynovial connective tissue is an integral component of flexor tendon gliding in the carpal tunnel, which is strained during longitudinal tendon displacement. We tested the effects of repetition frequency and finger load on flexor tendon function throughout active finger movement. Eleven participants performed metacarpophalangeal joint flexion/extension of the long finger cyclically at three repetition frequencies (0.75, 1.00, 1.25 Hz) and two finger loads (3.5, 7 N). Relative displacement between the flexor digitorum superficialis tendon and subsynovial connective tissue was assessed as the shear-strain index with color ultrasound throughout the entire time history of finger flexion and extension. In addition, long finger joint angles were measured with electrogoniometry while flexor digitorum superficialis and extensor digitorum muscle activities were measured with fine-wire electromyography to characterize the finger movements. The shear-strain index increased with greater finger flexion (p = 0.001), representing higher relative displacement between tendon and subsynovial connective tissue; however, no changes were observed throughout finger extension. The shear-strain index also increased with higher repetition frequencies (p = 0.013) and finger loads (p = 0.029), further modulating time-dependent effects during finger flexion versus extension. Using ultrasound, we characterized the time-dependent response of the shear-strain index, in vivo, providing valuable data on flexor tendon function during active finger movement. Our results infer greater subsynovial connective tissue strain and shear during repetitive and forceful finger movements. Future research characterizing time-dependent effects in carpal tunnel syndrome patients may further elucidate the relations between subsynovial connective tissue function, damage, and carpal tunnel syndrome.
引用
收藏
页码:1661 / 1669
页数:9
相关论文
共 50 条
  • [1] Detection of differential gliding characteristics of the flexor digitorum superficialis tendon and subsynovial connective tissue using color Doppler sonographic imaging
    Oh, Sangho
    Belohlavek, Marek
    Zhao, Chunfeng
    Osamura, Naoki
    Zobitz, Mark E.
    an, Kai-N An
    Amadio, Peter C.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2007, 26 (02) : 149 - 155
  • [2] External Compression and Partial Ischemia Decrease Human Finger Flexor Tendon and Subsynovial Connective Tissue Relative Motion
    Tse, Calvin T. F.
    Keir, Peter J.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2020, 38 (05) : 1038 - 1044
  • [3] SPECKLE TRACKING ULTRASOUND FOR ASSESSMENT OF THE RELATIVE MOTION OF FLEXOR TENDON AND SUBSYNOVIAL CONNECTIVE TISSUE IN THE HUMAN CARPAL TUNNEL
    Yoshii, Yuichi
    Villarraga, Hector R.
    Henderson, Jacqueline
    Zhao, Chunfeng
    An, Kai-Nan
    Amadio, Peter C.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2009, 35 (12): : 1973 - 1981
  • [4] Validation of Color Doppler Sonography for Evaluating Relative Displacement Between the Flexor Tendon and Subsynovial Connective Tissue
    Tat, Jimmy
    Kociolek, Aaron M.
    Keir, Peter J.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2015, 34 (04) : 679 - 687
  • [5] Repetitive differential finger motion increases shear strain between the flexor tendon and subsynovial connective tissue
    Tat, Jimmy
    Kociolek, Aaron M.
    Keir, Peter J.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2013, 31 (10) : 1533 - 1539
  • [6] The chiasma of the flexor digitorum superficialis tendon
    Gonzalez, MH
    Nikoleit, J
    Weinzweig, N
    JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1998, 23B (02): : 234 - 236
  • [7] Relative motion between the flexor digitorum superficialis tendon and paratenon in zone V increases with wrist flexion angle
    Kociolek, Aaron M.
    Keir, Peter J.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2016, 34 (07) : 1248 - 1255
  • [8] ISOLATED AVULSION OF THE FLEXOR DIGITORUM SUPERFICIALIS TENDON
    STERN, JD
    MITRA, A
    SPEARS, J
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1995, 20A (04): : 642 - 644
  • [9] Spontaneous rupture of the flexor digitorum superficialis tendon of the little finger with aplasia of the flexor digitorum profundus tendon
    Miura, Toshiki
    Tokuyama, Naoto
    Ohya, Junichi
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2010, 35E (03) : 237 - 238
  • [10] FLEXOR DIGITORUM SUPERFICIALIS TENDON TRANSFER FOR WRIST EXTENSION
    Rondon, Alexander J.
    Aversano, Michael W.
    Kluemper, Chase T.
    Pino, Paula A.
    Kozin, Scott H.
    Zlotolow, Dan A.
    JBJS ESSENTIAL SURGICAL TECHNIQUES, 2021, 11 (04):