Effect of a Motion Artifact Correction System on Cone-Beam Computed Tomography Image Characteristics

被引:2
作者
Pahadia, Mayank [1 ]
Katkar, Rujuta [2 ]
Geha, Hassem [3 ]
机构
[1] Univ Florida, Oral & Maxillofacial Diagnost Sci, Gainesville, FL 32611 USA
[2] Univ Texas Hlth Sci Ctr San Antonio, Comprehens Dent Oral & Maxillofacial Radiol, San Antonio, TX USA
[3] Univ Texas Hlth Sci Ctr San Antonio, Oral & Maxillofacial Radiol, San Antonio, TX USA
关键词
contrast resolution; ct artifacts; motion correction; maxillofacial radiology; cone-beam computed tomography (cbct); PATIENT MOVEMENT; CBCT;
D O I
10.7759/cureus.35016
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: Determine the effect of the motion correction system on cone-beam computed tomography (CBCT) image quality parameters, artifacts, and contrast-to-noise ratio (CNR) using different motion settings.Materials and methods: A customized phantom insert array was prepared using SEDENTEX CT IQ Phantom (Leeds Test Objects, Yorkshire, England) stabilized over a rotating electric turntable. Thirty baseline CBCT scans were acquired with standardized technique factors on the ProMax 3D (Planmeca, Helsinki, Finland) machine using combinations of different motion settings, including no motion, three-and six-degree motion, and with and without the use of a motion correction system. The standardized images were exported to ImageJ software. Image quality parameters, artifacts, and CNR values were evaluated and compared among the different acquisition settings.Results: The use of the motion correction system algorithm compared with the different motion settings showed a statistically significant difference for all the parameters (p < 0.05) except for artifact values for six -degree motion (p < 0.07). The effect of different motion settings on the parameters was not statistically significant. Conclusion: The use of a motion correction system, a proprietary algorithm-based system incorporated in the ProMax 3D CBCT unit, deteriorates the image quality characteristics evaluated in this in vitro study, namely artifact value and CNR. Its use in clinical settings might be limited to situations where patient motion is expected and appropriate head stabilization is not possible due to age or disease.
引用
收藏
页数:9
相关论文
共 13 条
[1]   Evaluation of motion artifacts in cone-beam computed tomography with three different patient positioning [J].
Keris, Elif Yildizer ;
Demirel, Oguzhan ;
Ozdede, Melih .
ORAL RADIOLOGY, 2021, 37 (02) :276-281
[2]  
Leeds Test Objects Ltd, 2012, SEDENTEXCT IQ US MAN
[3]  
Mahesh M., 2013, ESSENTIAL PHYS MED I, VThird
[4]   Motion artefacts in cone beam CT: an in vitro study about the effects on the images [J].
Nardi, Cosimo ;
Molteni, Roberto ;
Lorini, Chiara ;
Taliani, Gian G. ;
Matteuzzi, Benedetta ;
Mazzoni, Elisa ;
Colagrande, Stefano .
BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1058)
[5]   Projection-based improvement of 3D reconstructions from motion-impaired dental cone beam CT data [J].
Niebler, Stefan ;
Schoemer, Elmar ;
Tjaden, Henning ;
Schwanecke, Ulrich ;
Schulze, Ralf .
MEDICAL PHYSICS, 2019, 46 (10) :4470-4480
[6]   Impact of movement and motion-artefact correction on image quality and interpretability in CBCT units with aligned and lateral-offset detectors [J].
Santaella, Gustavo Machado ;
Wenzel, Ann ;
Haiter-Neto, Francisco ;
Rosalen, Pedro Luiz ;
Spin-Neto, Rubens .
DENTOMAXILLOFACIAL RADIOLOGY, 2020, 49 (01)
[7]  
Scarfe William C, 2008, Dent Clin North Am, V52, P707, DOI 10.1016/j.cden.2008.05.005
[8]   Artefacts in CBCT: a review [J].
Schulze, R. ;
Heil, U. ;
Gross, D. ;
Bruellmann, D. D. ;
Dranischnikow, E. ;
Schwanecke, U. ;
Schoemer, E. .
DENTOMAXILLOFACIAL RADIOLOGY, 2011, 40 (05) :265-273
[9]   Automated detection of patient movement during a CBCT scan based on the projection data [J].
Schulze, Ralf K. W. ;
Michel, Michel ;
Schwanecke, Ulrich .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2015, 119 (04) :468-472
[10]   Impact of motion artefacts and motion-artefact correction on diagnostic accuracy of apical periodontitis in CBCT images: anex vivostudy in human cadavers [J].
Spin-Neto, R. ;
Kruse, C. ;
Hermann, L. ;
Kirkevang, L. -L. ;
Wenzel, A. .
INTERNATIONAL ENDODONTIC JOURNAL, 2020, 53 (09) :1275-1288