Electrochemical corrosion study of chitosan-hydroxyapatite coated dental implant

被引:5
作者
Anees, Etrat [1 ]
Riaz, Madeeha [1 ]
Imtiaz, Hina [1 ]
Hussain, Tousif [2 ]
机构
[1] Lahore Coll Women Univ, Phys Dept, Lahore, Pakistan
[2] Govt Coll Univ, Ctr Adv Studies Phys, Lahore, Pakistan
关键词
Electrochemical; Corrosion; Chitosan; Hydroxyapatite; COATINGS;
D O I
10.1016/j.jmbbm.2023.106268
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Chitosan (Ch) is a naturally occurring biocompatible and bio-degradable material with high corrosion protective capacities for metals in various corrosive media. Hydroxyapatite (HA) is a significant biodegradable and bioactive material. In the present work, chitosan-hydroxyapatite (Ch-HA) composite coatings with various concentrations of chitosan were made on 316L stainless steel (316L SS) using sol-gel dip coating technique. The coatings were characterized by X-ray diffraction (XRD), FTIR, SEM, and electrochemical measurements. The surface morphology results (SEM) of coated implants exposed the fairly dense microstructures having uniformity without cracks and pores indicating that coating was successfully deposited. From electrochemical analyses, it was observed that the value of corrosion current density and the corrosion rate decreased from 6.03 to 0.15 and 5.56-0.13 respectively indicating that 1.5gCh-HA is the best coating concentration. The electrochemical results demonstrated an improvement in the corrosion resistance of 316L SS than the bare one. The decrease in slope and loop area of cyclic voltammograms reveals about improvement in corrosion resistance. This increment in corrosion resistance of the Ch-HA coated SS implant in the artificial saliva is as 1.5gCh-HA > 2gCh-HA >1gCh-HA >0.5gCh-HA. Furthermore, Ch-HA coatings revealed appropriate adhesion with 316L SS substrate for its use in dental implants.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Magnetic chitosan-hydroxyapatite composite microspheres: Preparation, characterization, and application for the adsorption of phenolic substances
    Fan, Songlin
    Huang, Zuqiang
    Zhang, Yanjuan
    Hu, Huayu
    Liang, Xinquan
    Gong, Shanxi
    Zhou, Jing
    Tu, Ru
    BIORESOURCE TECHNOLOGY, 2019, 274 : 48 - 55
  • [22] Chitosan-Hydroxyapatite Bio-Based Composite in Film Form: Synthesis and Application in Wastewater
    Akartasse, Noureddine
    Azzaoui, Khalil
    Mejdoubi, Elmiloud
    Elansari, Lhaj Lahcen
    Hammouti, Belkhir
    Siaj, Mohamed
    Jodeh, Shehdeh
    Hanbali, Ghadir
    Hamed, Rinad
    Rhazi, Larbi
    POLYMERS, 2022, 14 (20)
  • [23] From crabshell to chitosan-hydroxyapatite composite material via a biomorphic mineralization synthesis method
    Haoran Ge
    Bingyuan Zhao
    Yijian Lai
    Xiaobin Hu
    Di Zhang
    Keao Hu
    Journal of Materials Science: Materials in Medicine, 2010, 21 : 1781 - 1787
  • [24] Microwave-assisted fabrication of chitosan-hydroxyapatite superporous hydrogel composites as bone scaffolds
    Beskardes, Isil Gercek
    Demirtas, Tugrul Tolga
    Durukan, Muge Dagli
    Gumusderelioglu, Menemse
    JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2015, 9 (11) : 1233 - 1246
  • [25] Study of the structural properties and degradation of coated wood with polydopamine/hydroxyapatite/chitosan hybrid nanocomposite in seawater
    Esfandiar, Narges
    Elmi, Fatemeh
    Omidzahir, Shila
    CELLULOSE, 2020, 27 (13) : 7779 - 7790
  • [26] Electrochemical corrosion behavior of dental/implant alloys in artificial saliva
    Sharma, Mohit
    Kumar, A. V. Ramesh
    Singh, Nirbhay
    Adya, Nidhi
    Saluja, Bobin
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2008, 17 (05) : 695 - 701
  • [27] Chitosan-hydroxyapatite nanocomposites: Effect of interfacial layer on mechanical and dielectric properties
    Gomez Sanchez, Alejandro
    Prokhorov, Evgen
    Luna-Barcenas, Gabriel
    Mora-Garcia, Alma G.
    Kovalenko, Yuriy
    Rivera-Munoz, Eric M.
    Grazia Raucci, Maria
    Buonocore, Giovanna
    MATERIALS CHEMISTRY AND PHYSICS, 2018, 217 : 151 - 159
  • [28] Electrochemical Corrosion Behavior of Dental/Implant Alloys in Artificial Saliva
    Mohit Sharma
    A.V. Ramesh Kumar
    Nirbhay Singh
    Nidhi Adya
    Bobin Saluja
    Journal of Materials Engineering and Performance, 2008, 17 : 695 - 701
  • [29] Characterization and in vivo evaluation of chitosan-hydroxyapatite bone scaffolds made by one step coprecipitation method
    Danilchenko, Sergei N.
    Kalinkevich, Oksana V.
    Pogorelov, Maksim V.
    Kalinkevich, Aleksei N.
    Sklyar, Anatoly M.
    Kalinichenko, Tatyana G.
    Ilyashenko, Vyacheslav Y.
    Starikov, Vadim V.
    Bumeyster, Valentina I.
    Sikora, Vitaly Z.
    Sukhodub, Leonid F.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2011, 96A (04) : 639 - 647
  • [30] Fabrication and characterization of electrophoretically deposited chitosan-hydroxyapatite composite coatings on anodic titanium dioxide layers
    Pawlik, Anna
    Rehman, Muhammad Atiq Ur
    Nawaz, Qaisar
    Bastan, Fatih E.
    Sulka, Grzegorz D.
    Boccaccini, Aldo R.
    ELECTROCHIMICA ACTA, 2019, 307 : 465 - 473