Seismic performance of circular concrete-filled FRP tubes consisting of H-steel with shear studs: Experimental study and numerical modelling

被引:12
作者
Zhang, Bing [1 ,2 ]
Gao, Yuhang [1 ]
Peng, Yutao [1 ]
Liu, Jin [3 ]
Zhang, Sumei [1 ,2 ]
Zhu, Enyi [1 ]
Jiang, Yuexin [4 ]
机构
[1] Harbin Inst Technol Shenzhen, Sch Civil & Environm Engn, Shenzhen 518055, Peoples R China
[2] Guangdong Prov Key Lab Intelligent & Resilient Str, Shenzhen 518055, Peoples R China
[3] Nanjing Tech Univ, Coll Civil Engn, Nanjing 211816, Peoples R China
[4] Suzhou Univ Sci & Technol, Sch Civil Engn, Suzhou 215011, Peoples R China
基金
中国国家自然科学基金;
关键词
FRP; Confinement; Profiled steel; Composite column; Hysteretic behaviour; Numerical simulation; STRESS-STRAIN MODEL; CONFINED CONCRETE; COMPRESSIVE BEHAVIOR; REINFORCING BARS; RC COLUMNS; STRENGTH; COMPOSITES; BRIDGE;
D O I
10.1016/j.tws.2023.111225
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Existing studies about concrete-filled FRP tubes (CFFTs) are generally focused on their behaviour under axial load, which have demonstrated their excellent compressive ductility. For their applications in regions with seismic risk, longitudinal reinforcements should be provided for CFFTs in order to ensure their ability to resist bending moments. In published literatures, longitudinal reinforcements for CFFTs were mostly steel rebars or FRP rebars, while only limited studies were about CFFTs reinforced with profiledsteel. Against this background, 6 circular large-scale CFFTs consisting of H-steel with shear studs (HS-CFFTs) were investigated experimentally under combined axial load and lateral cyclic load to study their seismic behaviour. These HS-CFFTs were designed with a total height of 2150 mm and a concrete diameter of 300 mm, and the testing parameters included the FRP thickness (tfrp = 4.0 mm - 6.0 mm), the axial load ratio (n = 0.2 - 0.33), as well as the area ratio of Hsteel (rho = 4.54% - 5.67%). Test results indicated that, (1) HS-CFFTs exhibited rounded hysteretic curves with ample energy dissipation capacity; (2) the H-steel experienced no local buckling due to the effective concrete support and the sufficient FRP confinement; (3) the FRP tube thickness was positively correlated with the peak lateral load and the ductility of HS-CFFTs; compared with HS-CFFTs with tfrp = 4 mm, HS-CFFTs with tfrp = 6 mm had a higher peak load FP (7.3% - 7.4% higher) and a larger ductility index 14 delta (3.4% - 11.7% higher); (4) increasing the H-steel ratio could effectively improve the seismic performance of HS-CFFTs; HSCFFTs with rho = 5.67% had higher peak load (2.5% - 10.0% higher) compared with those with rho = 4.54%; (5) the ductility of HS-CFFTs would decrease obviously as the axial load ratio increased; the ductility index 14 delta for HSCFFTs with n = 0.33 was smaller (14.1% - 25.0% lower) than the counterparts with n = 0.2. A numerical model incorporating with "NonlinearBeamColumn" elements as well as specific constitutive models for the FRP tube, the H-steel and the concrete core was established on the OpenSees platform. The proposed numerical model provided a simple, computationally efficient and reasonably accurate approach for simulating the hysteretic behaviour of HS-CFFTs.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Experimental study on shear resistance of self-stressing concrete filled circular steel tubes
    Chang Xu
    Lin Haixiao
    Huang Chengkui
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2009, 65 (04) : 801 - 807
  • [32] Experimental study of axial compression behavior of circular concrete-filled steel tubes after being loaded at an early age
    Zhang, Ji
    Ma, Lu
    Zhou, Changlin
    Lee, Dongkyu
    Filippou, Filip C.
    CONSTRUCTION AND BUILDING MATERIALS, 2021, 300 (300)
  • [33] Seismic performance of circular recycled aggregate concrete-filled steel tubular columns: FEM modelling and sensitivity analysis
    Xu, J. J.
    Chen, Z. P.
    Zhao, X. Y.
    Demartino, C.
    Ozbakkaloglu, T.
    Xue, J. Y.
    THIN-WALLED STRUCTURES, 2019, 141 : 509 - 525
  • [34] Experimental investigations into stocky composite columns of concrete-filled circular S690 steel tubes under compression
    Men, Pengfei
    Ho, H. C.
    Zhou, X. H.
    Chung, K. F.
    ENGINEERING STRUCTURES, 2024, 309
  • [35] Experimental research on seismic performance of steel fiber-reinforced recycled concrete-filled circular steel tube columns
    Zhao, Pengtuan
    Huang, Yue
    Liu, Zhenzhen
    Wang, Han
    Lu, Yiyan
    JOURNAL OF BUILDING ENGINEERING, 2022, 54
  • [36] Influence of shrinkage on compressive behavior of concrete-filled FRP tubes: An experimental study on interface gap effect
    Vincent, Thomas
    Ozbakkaloglu, Togay
    CONSTRUCTION AND BUILDING MATERIALS, 2015, 75 : 144 - 156
  • [37] Experimental and numerical investigation of the seismic performance of concrete-filled steel tubular composite columns with UHPC plates
    Wei, Jian-gang
    Ying, Hao-dong
    Yang, Yan
    Zhang, Wei
    Bao, Chen-guang
    STRUCTURES, 2023, 58
  • [38] Experimental and Analytical Study of Seismic Behavior of Special-Shaped Multicell Composite Concrete-Filled Steel Tube Columns
    Yin, Fei
    Xue, Su-Duo
    Cao, Wan-Lin
    Dong, Hong-Ying
    Wu, Hai-Peng
    JOURNAL OF STRUCTURAL ENGINEERING, 2020, 146 (01)
  • [39] Experimental and numerical study of compressive behavior of axially loaded circular ultra-high-performance concrete-filled tube columns
    Abadel, Aref A.
    Khan, M. Iqbal
    Masmoudi, Radhouane
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2022, 17
  • [40] Seismic Performance of Hybrid Columns of Concrete-Filled Square Steel Tube with FRP-Confined Concrete Core
    Feng, Peng
    Cheng, Shi
    Yu, Tao
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2018, 22 (04)