Experimental study on heat transfer performance using a hybrid cooling method combined of a flat-plate heat pipe and spray cooling

被引:4
|
作者
Ni, Qin [1 ]
Ling, Xiang [1 ]
机构
[1] Nanjing Tech Univ, Sch Mech & Power Engn, 30 PuZhu South Rd, Nanjing 211816, Peoples R China
关键词
A hybrid cooling system; Spray cooling; Heat transfer enhancement; Multi -nozzle array; Surface roughness; THERMAL PERFORMANCE; SINGLE-PHASE; VAPOR CHAMBER; PART; LOOP; MICRO; R134A; RESISTANCE; SURFACES; WATER;
D O I
10.1016/j.tsep.2023.102200
中图分类号
O414.1 [热力学];
学科分类号
摘要
A hybrid cooling system consists of spray cooling as condensing end and flat-plate heat pipe (FPHP) as heat -transfer medium was previously studied on the effects of the volume flow rate and the inlet temperature. As an extension, this paper using multi-nozzle arrays to promote the forced convection heat transfer and changing the surface roughness of the FPHP to improve the phase change heat transfer. It was found that the impinging energy and drainage channel formed by multi-nozzle arrays were the main reasons for the enhancement in convection region. However, in the phase-change section, a uniform thin liquid film and surface roughness apparently improved the evaporation and nucleate boiling. Relative to our previous study, a maximum heat flux removal was increased from 70 W/cm(2) to 90 W/cm(2) at surface roughness (Ra = 1.62 mu m) with a surface superheat only 4.17 degrees C, the heat transfer coefficient of 21.6 W & sdot;cm(-2)& sdot;K-1 and an enhancement of 28.6 % were obtained. Furthermore, the transition temperature and the temperature change rate were studied to explore the vapor flow modes and thermal response characteristics of the FPHP. As the transition temperature T-tr = 251 K, and the Knusden number <0.01, the FPHP consistently maintained a continuum flow regime during startup, stabilization, and dry-out processes. Impressively, the temperature change rate of the FPHP remained below 0.015 degrees C/s, resulting in a temperature change of only 0.9 degrees C within one minute. This exceptional temperature stability ensured reliable operation for electronic components.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Thermal management strategy for electronic chips based on combination of a flat-plate heat pipe and spray cooling
    Zhao, Juan
    Du, Mingsheng
    Zhang, Zhen
    Ling, Xiang
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2021, 181
  • [2] An experimental investigation of heat transfer performance of a flat plate heat pipe with a combined capillary structure
    Wang, Yiwei
    Cen, Jiwen
    Jiang, Fangming
    HEAT AND MASS TRANSFER, 2019, 55 (04) : 1155 - 1165
  • [3] Visualization study and analysis on the heat transfer performance of an ultra-thin flat-plate heat pipe
    Liao, Xiaonan
    Jian, Qifei
    Zu, Shuaifei
    Li, Deqiang
    Huang, Zhe
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2021, 126
  • [4] Experimental Study on Impact of Installation Angle on Heat Transfer Performance of Spray Cooling
    Pang Liping
    Liu Zhixuan
    Jin Shicheng
    Ji Yibin
    Zhang Yu
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON LOGISTICS, ENGINEERING, MANAGEMENT AND COMPUTER SCIENCE, 2014, 101 : 250 - 253
  • [5] Experimental study of flat heat pipe for cooling TV Boxes
    Zeghari, Kaoutar
    Louahlia-Gualous, Hasna
    Ternet, Francois
    Lemasson, Stephane
    2018 IEEE INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE (INTELEC), 2018,
  • [6] Comparative study on the heat transfer characteristics of spray cooling in confined spray chambers
    Xie, J. L.
    Ranjith, K.
    Wong, T. N.
    Lee, H. M.
    APPLIED THERMAL ENGINEERING, 2020, 164
  • [7] Experimental study on the transient heat transfer performance of spray cooling during swing excitation
    Zhao, Ke
    Jiang, Yanlong
    Fu, Quan
    Zhu, Faxing
    Wang, Yu
    Xu, Yizhe
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2025, 211
  • [8] Experimental study on heat transfer characteristics of spray cooling system with plate-fin heat exchanger
    Jin, Qi
    Yu, Yanshun
    Xia, Yaobiao
    EXPERIMENTAL HEAT TRANSFER, 2024, 37 (06) : 767 - 779
  • [9] Experimental study on the heat transfer performance and dimensionless correlations for R134a spray cooling system
    Zhou, Nianyong
    Guo, Yixing
    Liu, Wenbo
    Peng, Haoping
    Lei, Yun
    Deng, Song
    Feng, Hao
    Xu, Yu
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2023, 237 (03) : 550 - 558
  • [10] Experimental study on heat transfer enhancement of wavy finned flat tubes by water spray cooling
    Xiao, Liehui
    Wu, Tao
    Feng, Shuqin
    Du, Xiaoze
    Yang, Lijun
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 110 : 383 - 392