Enhanced honey badger optimization of performance analysis of evacuated tube heat pipe solar collector integrated with PCM storage unit

被引:1
|
作者
Ramesh, C. [1 ]
Vijayakumar, M. [2 ]
Kumaresan, G. [3 ]
Selvanayagam, Benjamin Franklin [4 ]
机构
[1] KIT Kalaignar Karunanidhi Inst Technol, Dept Mech Engn, Coimbatore 641402, Tamil Nadu, India
[2] PSN Coll Engn & Technol, Dept Mech Engn, Tirunelveli, Tamil Nadu, India
[3] Bannari Amman Inst Technol, Dept Mech Engn, Sathyamangalam, Tamil Nadu, India
[4] Sri Ramakrishna Inst Technol, Dept Mech Engn, Coimbatore, Tamil Nadu, India
关键词
Heat pipe; phase change material; aluminum fin; fin temperature; optimization; thermal energy storage; liquid fractions; PHASE-CHANGE MATERIAL; THERMAL PERFORMANCE; WATER-HEATER; SYSTEM; TANK;
D O I
10.1177/0958305X231189187
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A hybrid method for improving the efficiency of heat pipe evacuated-tube solar-collector (HPETC) is proposed for incorporating the phase-change materials (PCMs) in both off-demand and regular operation. The proposed hybrid approach is called an improved honey badger algorithm (HBA). The crossover and mutation operator improves the honey badger's (HB) foraging habit. The proposed approach aims to generate hot air at various rates of airflow under incident and nonincident solar-radiation situations. The analysis is done on the effects of different energy-storage systems and the position of the heat pipe (HP). In a normal heat-pipe evacuated-tube solar collector, the HP is put within the glass tube that is closer to the upper-surface, and it is held in place through an aluminum fin. However, in the proposed method, the HP is rearranged in the tube's middle. In order to identify the PCM with the highest average-fin temperature, the temperatures of the area-weighted average-fin are measured and compared throughout the glass tubes under typical conditions. For maximizing the thermal-energy carrying capability, the average liquid fraction volume of PCMs is measured for a 24-h flow period. The average liquid-fraction volume of PCMs is continuously observed in stagnation mode till the glass tube reaches the maximal value. The structured mesh patch conforming method is used to invalidate the HPETC system's constituent parts, improving numerical stability and convergence. The proposed method efficiency is 0.43. The proposed method shows high efficiency compared with other existing methods.
引用
收藏
页码:471 / 498
页数:28
相关论文
共 50 条
  • [21] Modeling and Performance Optimization of the U-pipe Glass Evacuated Tube Solar Collector
    Chen, Xiaomeng
    Guo, Fang
    Wang, Chunlin
    Yang, Xudong
    PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA, 2020, : 4436 - 4442
  • [22] Thermal performance investigation of energy storage based U-pipe evacuated tube solar collector: An experimental study
    O'Neil, Tyler J. E.
    Sobhansarbandi, Sarvenaz
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 52
  • [23] An active solar desalination system integrated with collective condenser heat pipe solar evacuated tube collector: a thermoeconomic analysis
    Garima Nema
    Karunamurthy Krishnasamy
    Environmental Science and Pollution Research, 2024, 31 : 10273 - 10295
  • [24] Thermal performance of a heat-pipe evacuated-tube solar collector at high inlet temperatures
    Elsheniti, Mahmoud B.
    Kotb, Amr
    Elsamni, Osama
    APPLIED THERMAL ENGINEERING, 2019, 154 : 315 - 325
  • [25] Evacuated tube solar thermal collector with enhanced phase change material thermal storage: An experimental study
    Senobar, Hossein
    Aramesh, Mohamad
    Shabani, Bahman
    JOURNAL OF ENERGY STORAGE, 2022, 46
  • [26] Evacuated tube solar heat pipe collector model and associated tests
    Jafarkazemi, Farzad
    Abdi, Hossein
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2012, 4 (02)
  • [27] Performance of a solar still integrated with evacuated tube collector in natural mode
    Singh, Ragh Vendra
    Kumar, Shiv
    Hasan, M. M.
    Khan, M. Emran
    Tiwari, G. N.
    DESALINATION, 2013, 318 : 25 - 33
  • [28] Theoretical and experimental studies of impacts of heat shields on heat pipe evacuated tube solar collector
    Huang, Xiaona
    Wang, Qiliang
    Yang, Honglun
    Zhong, Shuai
    Jiao, Dongsheng
    Zhang, Kaili
    Li, Mujun
    Pei, Gang
    RENEWABLE ENERGY, 2019, 138 : 999 - 1009
  • [29] Sustainable hydrogen production by integrating solar PV electrolyser and solar evacuated tube collector with hybrid nanoparticles enhanced PCM
    Sathish, T.
    APPLIED THERMAL ENGINEERING, 2024, 257
  • [30] Modeling and optimization of a thermal energy storage unit with cascaded PCM capsules in connection to a solar collector
    Nekoonam, Saeed
    Ghasempour, Roghayeh
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 52