Enhanced honey badger optimization of performance analysis of evacuated tube heat pipe solar collector integrated with PCM storage unit

被引:1
|
作者
Ramesh, C. [1 ]
Vijayakumar, M. [2 ]
Kumaresan, G. [3 ]
Selvanayagam, Benjamin Franklin [4 ]
机构
[1] KIT Kalaignar Karunanidhi Inst Technol, Dept Mech Engn, Coimbatore 641402, Tamil Nadu, India
[2] PSN Coll Engn & Technol, Dept Mech Engn, Tirunelveli, Tamil Nadu, India
[3] Bannari Amman Inst Technol, Dept Mech Engn, Sathyamangalam, Tamil Nadu, India
[4] Sri Ramakrishna Inst Technol, Dept Mech Engn, Coimbatore, Tamil Nadu, India
关键词
Heat pipe; phase change material; aluminum fin; fin temperature; optimization; thermal energy storage; liquid fractions; PHASE-CHANGE MATERIAL; THERMAL PERFORMANCE; WATER-HEATER; SYSTEM; TANK;
D O I
10.1177/0958305X231189187
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A hybrid method for improving the efficiency of heat pipe evacuated-tube solar-collector (HPETC) is proposed for incorporating the phase-change materials (PCMs) in both off-demand and regular operation. The proposed hybrid approach is called an improved honey badger algorithm (HBA). The crossover and mutation operator improves the honey badger's (HB) foraging habit. The proposed approach aims to generate hot air at various rates of airflow under incident and nonincident solar-radiation situations. The analysis is done on the effects of different energy-storage systems and the position of the heat pipe (HP). In a normal heat-pipe evacuated-tube solar collector, the HP is put within the glass tube that is closer to the upper-surface, and it is held in place through an aluminum fin. However, in the proposed method, the HP is rearranged in the tube's middle. In order to identify the PCM with the highest average-fin temperature, the temperatures of the area-weighted average-fin are measured and compared throughout the glass tubes under typical conditions. For maximizing the thermal-energy carrying capability, the average liquid fraction volume of PCMs is measured for a 24-h flow period. The average liquid-fraction volume of PCMs is continuously observed in stagnation mode till the glass tube reaches the maximal value. The structured mesh patch conforming method is used to invalidate the HPETC system's constituent parts, improving numerical stability and convergence. The proposed method efficiency is 0.43. The proposed method shows high efficiency compared with other existing methods.
引用
收藏
页码:471 / 498
页数:28
相关论文
共 50 条
  • [11] Improving solar still performance with heat pipe/pulsating heat pipe evacuated tube solar collectors and PCM: An experimental and environmental analysis
    Hemmatian, Amir
    Kargarsharifabad, Hadi
    Esfahlani, Ahad Abedini
    Rahbar, Nader
    Shoeibi, Shahin
    SOLAR ENERGY, 2024, 269
  • [12] Thermal performance of U-pipe evacuated tube solar collector with latent heat thermal energy storage
    Liu Y.
    Li T.
    Li Y.
    Chen Y.
    Wang D.
    Liu J.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2021, 42 (07): : 244 - 250
  • [13] Performance of evacuated tube solar collector integrated solar desalination unit - a review
    Kumar, Rajeev
    Singh, Desh Bandhu
    Dewangan, Ashish
    Singh, Vivek Kumar
    Kumar, Navneet
    DESALINATION AND WATER TREATMENT, 2021, 230 : 92 - 115
  • [14] An active solar desalination system integrated with collective condenser heat pipe solar evacuated tube collector: a thermoeconomic analysis
    Nema, Garima
    Krishnasamy, Karunamurthy
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2024, 31 (07) : 10273 - 10295
  • [15] COMPUTATIONAL FLUID DYNAMICS MODELING OF A HEAT PIPE EVACUATED TUBE SOLAR COLLECTOR INTEGRATED WITH PHASE CHANGE MATERIAL
    Pawar, Vivek R.
    Sobhansarbandi, Sarvenaz
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2019, VOL 6, 2019,
  • [16] Experimental evaluation of a self storage integrated evacuated tube solar thermal collector
    Aramesh, Mohamad
    Shabani, Bahman
    JOURNAL OF ENERGY STORAGE, 2023, 62
  • [17] A novel thermal storage integrated evacuated tube heat pipe solar air heater: Energy, exergy, economic and environmental impact analysis
    Mathew, Adarsh Abi
    Thangavel, Venugopal
    SOLAR ENERGY, 2021, 220 : 828 - 842
  • [18] Latent and sensible heat thermal storage in a heat pipe-based evacuated tube solar dryer: A comparative performance analysis
    Mathew, Adarsh Abi
    Thangavel, Venugopal
    Mandhare, Neeta Amol
    Nukulwar, Masnaji R.
    JOURNAL OF ENERGY STORAGE, 2023, 57
  • [19] Heat Pipe Evacuated Tubular Solar Collector Performance Improvement By Applications of Nanofluid
    Su, Umut Onder
    Sozen, Adnan
    Menlik, Tayfun
    JOURNAL OF POLYTECHNIC-POLITEKNIK DERGISI, 2019, 22 (01): : 245 - 257
  • [20] Analysis of micro heat pipe array based evacuated tube solar water heater integrated with an energy storage system for improved thermal performance
    Tamuli, Bhaskar Ranjan
    Nath, Sujit
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2023, 41