Enhanced honey badger optimization of performance analysis of evacuated tube heat pipe solar collector integrated with PCM storage unit

被引:1
|
作者
Ramesh, C. [1 ]
Vijayakumar, M. [2 ]
Kumaresan, G. [3 ]
Selvanayagam, Benjamin Franklin [4 ]
机构
[1] KIT Kalaignar Karunanidhi Inst Technol, Dept Mech Engn, Coimbatore 641402, Tamil Nadu, India
[2] PSN Coll Engn & Technol, Dept Mech Engn, Tirunelveli, Tamil Nadu, India
[3] Bannari Amman Inst Technol, Dept Mech Engn, Sathyamangalam, Tamil Nadu, India
[4] Sri Ramakrishna Inst Technol, Dept Mech Engn, Coimbatore, Tamil Nadu, India
关键词
Heat pipe; phase change material; aluminum fin; fin temperature; optimization; thermal energy storage; liquid fractions; PHASE-CHANGE MATERIAL; THERMAL PERFORMANCE; WATER-HEATER; SYSTEM; TANK;
D O I
10.1177/0958305X231189187
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A hybrid method for improving the efficiency of heat pipe evacuated-tube solar-collector (HPETC) is proposed for incorporating the phase-change materials (PCMs) in both off-demand and regular operation. The proposed hybrid approach is called an improved honey badger algorithm (HBA). The crossover and mutation operator improves the honey badger's (HB) foraging habit. The proposed approach aims to generate hot air at various rates of airflow under incident and nonincident solar-radiation situations. The analysis is done on the effects of different energy-storage systems and the position of the heat pipe (HP). In a normal heat-pipe evacuated-tube solar collector, the HP is put within the glass tube that is closer to the upper-surface, and it is held in place through an aluminum fin. However, in the proposed method, the HP is rearranged in the tube's middle. In order to identify the PCM with the highest average-fin temperature, the temperatures of the area-weighted average-fin are measured and compared throughout the glass tubes under typical conditions. For maximizing the thermal-energy carrying capability, the average liquid fraction volume of PCMs is measured for a 24-h flow period. The average liquid-fraction volume of PCMs is continuously observed in stagnation mode till the glass tube reaches the maximal value. The structured mesh patch conforming method is used to invalidate the HPETC system's constituent parts, improving numerical stability and convergence. The proposed method efficiency is 0.43. The proposed method shows high efficiency compared with other existing methods.
引用
收藏
页码:471 / 498
页数:28
相关论文
共 50 条
  • [1] Theoretical model of an evacuated tube heat pipe solar collector integrated with phase change material
    Naghavi, M. S.
    Ong, K. S.
    Badruddin, I. A.
    Mehrali, M.
    Silakhori, M.
    Metselaar, H. S. C.
    ENERGY, 2015, 91 : 911 - 924
  • [2] Experimental and Theoretical Analysis for the Performance of Evacuated Tube Collector Integrated with Helical Finned Heat Pipes using PCM Energy Storage
    Essa, Mohamed A.
    Rofaiel, Ibrahim Y.
    Ahmed, Mohamed A.
    ENERGY, 2020, 206
  • [3] Thermal performance of a solar cooker based on an evacuated tube solar collector with a PCM storage unit
    Sharma, SD
    Iwata, T
    Kitano, H
    Sagara, K
    SOLAR ENERGY, 2005, 78 (03) : 416 - 426
  • [4] INTEGRATION OF THERMAL ENERGY STORAGE MATERIALS IN HEAT PIPE EVACUATED TUBE SOLAR COLLECTOR SYSTEMS FOR ENHANCED SOLAR THERMAL PERFORMANCE
    Hachim, Dhafer Manea
    Eidan, Adel A.
    Alshukri, Mohammed J.
    Al-Fahham, Mohamed
    Alsahlani, Assaad
    Al-Manea, Ahmed
    Al-Rbaihat, Raed
    Alahmer, Ali
    COMPUTATIONAL THERMAL SCIENCES, 2024, 16 (06): : 59 - 85
  • [5] Heat transfer enhancement of a PCM-porous metal based heat pipe evacuated tube solar collector: An experimental study
    Pawar, Vivek R.
    Sobhansarbandi, Sarvenaz
    SOLAR ENERGY, 2023, 251 : 106 - 118
  • [6] CFD modeling of a thermal energy storage based heat pipe evacuated tube solar collector
    Pawar, Vivek R.
    Sobhansarbandi, Sarvenaz
    JOURNAL OF ENERGY STORAGE, 2020, 30
  • [7] Experimental investigation of a desiccant dehumidifier based on evacuated tube solar collector with a PCM storage unit
    Mehla, Neeraj
    Yadav, Avadhesh
    DRYING TECHNOLOGY, 2017, 35 (04) : 417 - 432
  • [8] Thermal performance of phase change material integrated heat pipe evacuated tube solar collector system: An experimental assessment
    Chopra, K.
    Pathak, Atin K.
    Tyagi, V. V.
    Pandey, A. K.
    Anand, Sanjeev
    Sari, Ahmet
    ENERGY CONVERSION AND MANAGEMENT, 2020, 203
  • [9] Experimental performance evaluation of a novel designed phase change material integrated manifold heat pipe evacuated tube solar collector system
    Chopra, K.
    Tyagi, V. V.
    Pathak, Atin K.
    Pandey, A. K.
    Sari, Ahmet
    ENERGY CONVERSION AND MANAGEMENT, 2019, 198
  • [10] Experimental investigation of an evacuated tube solar collector incorporating nano-enhanced PCM as a thermal booster
    Algarni, Salem
    Mellouli, Sofiene
    Alqahtani, Talal
    Almutairi, Khalid
    Khan, Afrouz
    Anqi, Ali
    APPLIED THERMAL ENGINEERING, 2020, 180