Comparison of Corneal Thickness Measurements After Customized Corneal Crosslinking Using High-Resolution Optical Coherence Tomography and Scheimpflug Tomography

被引:2
作者
Baiao, Tiago Mendes [1 ,2 ,3 ]
Wendelstein, Jascha [1 ,4 ,5 ]
Seiler, Theo G. [1 ,3 ,6 ,7 ,8 ]
机构
[1] Inst Refrakt Ophthalmo Chirurg IROC, Zurich, Switzerland
[2] Berner Augenklin Lindenhofspital, Bern, Switzerland
[3] Univ Bern, Med Fac, Bern, Switzerland
[4] Johannes Kepler Univ Linz, Med Fac, Dept Ophthalmol, Linz, Austria
[5] Saarland Univ, Inst Expt Ophthalmol, Homburg, Germany
[6] Inselspital Bern, Univ Klin Augenheilkunde, Bern, Switzerland
[7] Univ Klinikum Dusseldorf, Klin Augenheilkunde, Dusseldorf, Germany
[8] Inst Refrakt Ophthalmochirurg IROC AG, Stockerstr 37, CH-8002 Zurich, Switzerland
关键词
comparison; corneal thickness; crosslinking; CXL; keratoconus; MS-39; OCT; pachymetry; Pentacam; ANTERIOR SEGMENT OCT; KERATOCONUS; PACHYMETRY; REPEATABILITY; ULTRASOUND; ORBSCAN; HAZE;
D O I
10.1097/ICO.0000000000003158
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:The aim of this study was to compare the evolution of corneal pachymetry after customized corneal crosslinking (CXL) between Scheimpflug-based and optical coherence-based corneal tomography (OCT).Methods:In this retrospective study, central corneal thickness (CCT), thinnest corneal thickness, and epithelial thickness of 33 eyes of 33 patients with keratoconus were measured preoperatively and 1, 3, and 12 months after customized CXL using the Pentacam HR and the MS-39. The mean pachymetry values of measurements were compared with a paired sample t test. Bland-Altman plots and 95% limits of agreement (LoA) were used to assess the agreement between the measurements of the 2 devices.Results:The mean age of the participants was 29.7 & PLUSMN; 11.4 years. At baseline, the mean CCT measurements were equal with Pentacam HR (478.30 & PLUSMN; 36.77 & mu;m) and MS-39 (478.46 & PLUSMN; 38.01 & mu;m). After CXL, CCT obtained by Pentacam HR was 460.65 & PLUSMN; 38.69 & mu;m, 464.65 & PLUSMN; 44.45 & mu;m, and 476.77 & PLUSMN; 39.85 & mu;m, and by MS-39 was 478.18 & PLUSMN; 39.50 & mu;m, 472.89 & PLUSMN; 40.92 & mu;m, and 479.51 & PLUSMN; 39.20 & mu;m at 1, 3, and 12 months, respectively. Pentacam HR measured significantly lower CCT (P < 0.05) at months 1 and 3 after CXL. The agreement was smallest between both devices at month 1 (95% LoA -59 to 24 & mu;m) followed by month 3 (95% LoA: -41 to 23 & mu;m). Epithelial thickness, measured with OCT alone, increased significantly at 1 month and regained preoperative levels at 3 months and thereafter.Conclusions:After CXL, corneal pachymetry significantly differs between OCT-based and Scheimpflug-based corneal tomography. Pentacam HR seems to underestimate pachymetry when haze is present.
引用
收藏
页码:1104 / 1109
页数:6
相关论文
共 50 条
  • [41] Investigation of the Sectorized Corneal Thickness of Eyes With Corneal Endothelial Dysfunction Using Anterior-Segment Optical Coherence Tomography
    Omoto, Takashi
    Kim, Minjae
    Goto, Hiroki
    Abe, Yuito
    Ono, Takashi
    Taketani, Yukako
    Toyono, Tetsuya
    Yoshida, Junko
    Usui, Tomohiko
    Yamagami, Satoru
    Aihara, Makoto
    Miyai, Takashi
    CORNEA, 2023, 42 (06) : 714 - 718
  • [42] Comparison of Central Corneal Thickness with Ultrasound Pachymetry, Noncontact Specular Microscopy and Spectral Domain Optical Coherence Tomography
    Erdur, Sevil Karaman
    Demirci, Goktug
    Dikkaya, Funda
    Kocabora, Mehmet Selim
    Ozsutcu, Mustafa
    SEMINARS IN OPHTHALMOLOGY, 2018, 33 (06) : 782 - 787
  • [43] Change of corneal radii after Descemet membrane endothelial keratoplasty measured by optical coherence tomography and Scheimpflug tomography
    Diener, Raphael
    Eter, Nicole
    Alnawaiseh, Maged
    OPHTHALMOLOGE, 2021, 118 (12): : 1249 - 1254
  • [44] Evaluation of Corneal Epithelial Thickness Imaged by High Definition Optical Coherence Tomography in Healthy Eyes
    Baghdasaryan, Elmira
    Tepelus, Tudor C.
    Marion, Kenneth M.
    Bagherinia, Homayoun
    Sadda, SriniVas R.
    Hsu, Hugo Y.
    CORNEA, 2019, 38 (01) : 62 - 66
  • [45] Corneal Thickness and Volume Measurements by Swept Source Anterior Segment Optical Coherence Tomography in Normal Subjects
    Fukuda, Reina
    Usui, Tomohiko
    Miyai, Takashi
    Mori, Yosai
    Miyata, Kazunori
    Amano, Shiro
    CURRENT EYE RESEARCH, 2013, 38 (05) : 531 - 536
  • [46] Comparison of Oculus Pentacam and Stratus Optical Coherence Tomography for Measurement of Central Corneal Thickness
    Ceylan, Osman Melih
    Turk, Adem
    Erdurman, Cuneyt
    Mumcuoglu, Tarkan
    Erdem, Uzeyir
    Gokce, Gokcen
    Dagli, Selim
    CORNEA, 2011, 30 (06) : 670 - 674
  • [47] Consistency of corneal sublayer thickness measurements using Fourier-domain optical coherence tomography after phacoemulsification
    Lopez-Miguel, Alberto
    Calabuig-Goena, Maria
    Marques-Fernandez, Victoria
    Fernandez, Itziar
    Alio, Jorge L.
    Maldonado, Miguel J.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2016, 26 (06) : 540 - 545
  • [48] Comparison of Artemis 2 Ultrasound and Visante Optical Coherence Tomography Corneal Thickness Profiles
    Ursea, Roxana
    Feng, Matthew
    Urs, Raksha
    RoyChoudhury, Arindam
    Silverman, Ronald H.
    JOURNAL OF REFRACTIVE SURGERY, 2013, 29 (01) : 36 - +
  • [49] Evaluation of agreement in corneal thickness measurements obtained using optical coherence tomography and ultrasound technique and determination of its specificity in keratoconus screening
    Gunvant, P.
    Darner, R.
    MEDICAL IMAGING 2011: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2011, 7966
  • [50] Reproducibility of Scheimpflug Tomography Measurements Regarding Corneal Front and Back Surface Power
    Stavridis, E.
    Eppig, T.
    Szentmary, N.
    Seitz, B.
    Langenbucher, A.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2015, 232 (11) : 1297 - 1303