Comparison of Corneal Thickness Measurements After Customized Corneal Crosslinking Using High-Resolution Optical Coherence Tomography and Scheimpflug Tomography

被引:2
|
作者
Baiao, Tiago Mendes [1 ,2 ,3 ]
Wendelstein, Jascha [1 ,4 ,5 ]
Seiler, Theo G. [1 ,3 ,6 ,7 ,8 ]
机构
[1] Inst Refrakt Ophthalmo Chirurg IROC, Zurich, Switzerland
[2] Berner Augenklin Lindenhofspital, Bern, Switzerland
[3] Univ Bern, Med Fac, Bern, Switzerland
[4] Johannes Kepler Univ Linz, Med Fac, Dept Ophthalmol, Linz, Austria
[5] Saarland Univ, Inst Expt Ophthalmol, Homburg, Germany
[6] Inselspital Bern, Univ Klin Augenheilkunde, Bern, Switzerland
[7] Univ Klinikum Dusseldorf, Klin Augenheilkunde, Dusseldorf, Germany
[8] Inst Refrakt Ophthalmochirurg IROC AG, Stockerstr 37, CH-8002 Zurich, Switzerland
关键词
comparison; corneal thickness; crosslinking; CXL; keratoconus; MS-39; OCT; pachymetry; Pentacam; ANTERIOR SEGMENT OCT; KERATOCONUS; PACHYMETRY; REPEATABILITY; ULTRASOUND; ORBSCAN; HAZE;
D O I
10.1097/ICO.0000000000003158
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:The aim of this study was to compare the evolution of corneal pachymetry after customized corneal crosslinking (CXL) between Scheimpflug-based and optical coherence-based corneal tomography (OCT).Methods:In this retrospective study, central corneal thickness (CCT), thinnest corneal thickness, and epithelial thickness of 33 eyes of 33 patients with keratoconus were measured preoperatively and 1, 3, and 12 months after customized CXL using the Pentacam HR and the MS-39. The mean pachymetry values of measurements were compared with a paired sample t test. Bland-Altman plots and 95% limits of agreement (LoA) were used to assess the agreement between the measurements of the 2 devices.Results:The mean age of the participants was 29.7 & PLUSMN; 11.4 years. At baseline, the mean CCT measurements were equal with Pentacam HR (478.30 & PLUSMN; 36.77 & mu;m) and MS-39 (478.46 & PLUSMN; 38.01 & mu;m). After CXL, CCT obtained by Pentacam HR was 460.65 & PLUSMN; 38.69 & mu;m, 464.65 & PLUSMN; 44.45 & mu;m, and 476.77 & PLUSMN; 39.85 & mu;m, and by MS-39 was 478.18 & PLUSMN; 39.50 & mu;m, 472.89 & PLUSMN; 40.92 & mu;m, and 479.51 & PLUSMN; 39.20 & mu;m at 1, 3, and 12 months, respectively. Pentacam HR measured significantly lower CCT (P < 0.05) at months 1 and 3 after CXL. The agreement was smallest between both devices at month 1 (95% LoA -59 to 24 & mu;m) followed by month 3 (95% LoA: -41 to 23 & mu;m). Epithelial thickness, measured with OCT alone, increased significantly at 1 month and regained preoperative levels at 3 months and thereafter.Conclusions:After CXL, corneal pachymetry significantly differs between OCT-based and Scheimpflug-based corneal tomography. Pentacam HR seems to underestimate pachymetry when haze is present.
引用
收藏
页码:1104 / 1109
页数:6
相关论文
共 50 条
  • [1] Comparison of Scheimpflug Corneal Tomography and Anterior Segment Optical Coherence Tomography Measurements in Corneal Cystinosis: A Case Series
    Vercauteren, Leonie
    Consejo, Alejandra
    De Vries, Meindert Jan
    Krolo, Iva
    Koppen, Carina
    Dhubhghaill, Sorcha Ni
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2024, 50 (07): : 321 - 328
  • [2] A Comparison between Scheimpflug Imaging and Optical Coherence Tomography in Measuring Corneal Thickness
    Huang, Jinhai
    Ding, Xixia
    Savini, Giacomo
    Pan, Chao
    Feng, Yifan
    Cheng, Dan
    Hua, Yanjun
    Hu, Xiuli
    Wang, Qinmei
    OPHTHALMOLOGY, 2013, 120 (10) : 1951 - 1958
  • [3] Comparison of central corneal thickness measurements in corneal edema using ultrasound pachymetry, Visante anterior-segment optical coherence tomography, Cirrus optical coherence tomography, and Pentacam Scheimpflug camera tomography
    Wongchaisuwat, Nida
    Metheetrairat, Ankana
    Chonpimai, Pratuangsri
    Nujoi, Waree
    Prabhasawat, Pinnita
    CLINICAL OPHTHALMOLOGY, 2018, 12 : 1865 - 1873
  • [4] The repeatability of corneal and corneal epithelial thickness measurements using optical coherence tomography
    Sin, Sokpheaktra
    Simpson, Trefford L.
    OPTOMETRY AND VISION SCIENCE, 2006, 83 (06) : 360 - 365
  • [5] Comparison of central corneal thickness measurements using optical low-coherence reflectometry, Fourier domain optical coherence tomography, and Scheimpflug camera
    Gonul, Saban
    Koktekir, Bengu Ekinci
    Bakbak, Berker
    Gedik, Sansal
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2014, 77 (06) : 345 - 350
  • [6] "In Situ" Corneal and Contact Lens Thickness Changes with High-Resolution Optical Coherence Tomography
    Gonzalez-Meijome, Jose M.
    Cervino, Alejandro
    Peixoto-de-Matos, Sofia C.
    Madrid-Costa, David
    Jorge, Jorge
    Ferrer-Blasco, Teresa
    CORNEA, 2012, 31 (06) : 633 - 638
  • [7] Measurement of central corneal thickness by high-resolution Scheimpflug imaging, Fourier-domain optical coherence tomography and ultrasound pachymetry
    Chen, Shihao
    Huang, Jinhai
    Wen, Daizong
    Chen, Wuhe
    Huang, David
    Wang, Qinmei
    ACTA OPHTHALMOLOGICA, 2012, 90 (05) : 449 - 455
  • [8] Central and Midperipheral Corneal Thickness Measured with Scheimpflug Imaging and Optical Coherence Tomography
    Huang, Jinhai
    Ding, Xixia
    Savini, Giacomo
    Jiang, Zhengxuan
    Pan, Chao
    Hua, Yanjun
    Wu, Fan
    Feng, Yifan
    Yu, Ye
    Wang, Qinmei
    PLOS ONE, 2014, 9 (05):
  • [9] Repeatability and reproducibility of corneal thickness measurements by optical coherence tomography
    Muscat, S
    McKay, N
    Parks, S
    Kemp, E
    Keating, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 (06) : 1791 - 1795
  • [10] Corneal Tomography in a Commercially Available Optical Coherence Tomography Device and Comparison With a Rotating Scheimpflug Camera
    Kanclerz, Piotr
    Radomski, Szymon Adam
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2024, 50 (03): : 138 - 144