Plasma Cabozantinib Level Measurement in Patients with Renal Cell and Hepatocellular Carcinomas Using a Simple HPLC-UV Method Suitable for Clinical Application

被引:2
|
作者
Yasu, Takeo [1 ,2 ]
Gando, Yoshito [1 ]
Nishijima, Ryosuke [1 ]
Ikuta, Risa [2 ,3 ]
Suzuki, Motofumi [4 ]
Shirota, Mikio [2 ,5 ]
机构
[1] Meiji Pharmaceut Univ, Pharmaceut Educ & Res Ctr, Dept Med Therapy Res, Tokyo 2048588, Japan
[2] Meiji Pharmaceut Univ Joint Res Ctr, Bokutoh Hosp, Tokyo 1308575, Japan
[3] Tokyo Metropolitan Bokutoh Hosp, Dept Clin Lab, Tokyo 1308575, Japan
[4] Tokyo Metropolitan Bokutoh Hosp, Dept Urol, Tokyo 1308575, Japan
[5] Tokyo Metropolitan Bokutoh Hosp, Dept Pharm, Tokyo 1308575, Japan
基金
日本学术振兴会;
关键词
cabozantinib; high-performance liquid chromatography-ultraviolet; plasma concentration; therapeutic drug monitoring;
D O I
10.3390/curroncol30050367
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Cabozantinib, which is used to treat renal cell and hepatocellular carcinomas, is often associated with dose-dependent adverse events. Monitoring the levels of cabozantinib in the blood may maximize the therapeutic effect and prevent serious adverse events. In this study, we developed a high-performance liquid chromatography-ultraviolet (HPLC-UV) method of measuring plasma cabozantinib concentration. Human plasma samples (50 mu L) were processed by simple deproteinization with acetonitrile, followed by chromatographic separation on a reversed-phase column with an isocratic mobile phase of 0.5% KH2PO4 (pH 4.5) and acetonitrile (43:57, v/v) at a flow rate of 1.0 mL/min, with a 250 nm ultraviolet detector. The calibration curve was linear over the concentration range (0.05-5 mu g/mL) with a coefficient of determination of 0.99999. The accuracy of the assay ranged from -4.35% to 0.98%, and recovery was >96.04%. The measurement time was 9 min. These findings confirm the effectiveness of this HPLC-UV method for cabozantinib quantification in human plasma, which is sufficiently simple for use for monitoring patients in clinical settings.
引用
收藏
页码:4871 / 4879
页数:9
相关论文
共 34 条
  • [1] Quantitative determination of plasma cabozantinib concentration using HPLC-UV and its application to patients with renal cell carcinoma
    Maruyama, Shinichi
    Kato, Masaru
    Hiraga, Tatsuru
    Ishida, Masaru
    Kanno, Hiroshi
    BIOMEDICAL CHROMATOGRAPHY, 2023, 37 (05)
  • [2] A simple and rapid method for the measurement of ziprasidone in human plasma/serum by HPLC-UV
    Spencer, EP
    Coachman, L
    Jenkins, K
    Flanagan, RJ
    THERAPEUTIC DRUG MONITORING, 2005, 27 (02) : 226 - 226
  • [3] A Simple HPLC-UV Method for the Quantification of Theophylline in Rabbit Plasma and its Pharmacokinetic Application
    Al-Jenoobi, Fahad I.
    Ahad, Abdul
    Mahrous, Gamal M.
    Raish, Mohammad
    Alam, Mohd Aftab
    Al-Mohizea, Abdullah M.
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2015, 53 (10) : 1765 - 1770
  • [4] A Simple and Sensitive HPLC-UV Method for Quantitation of Lovastatin in Human Plasma: Application to a Bioequivalence Study
    Hamidi, Mehrdad
    Zarei, Najmeh
    Shahbazi, Mohammad-Ali
    BIOLOGICAL & PHARMACEUTICAL BULLETIN, 2009, 32 (09) : 1600 - 1603
  • [5] Determination of pterostilbene in rat plasma by a simple HPLC-UV method and its application in pre-clinical pharmacokinetic study
    Lin, Hai-Shu
    Yue, Bing-De
    Ho, Paul C.
    BIOMEDICAL CHROMATOGRAPHY, 2009, 23 (12) : 1308 - 1315
  • [6] Validation of an HPLC-UV method for sorafenib determination in human plasma and application to cancer patients in routine clinical practice
    Blanchet, B.
    Billemont, B.
    Cramard, J.
    Benichou, A. S.
    Chhun, S.
    Harcouet, L.
    Ropert, S.
    Dauphin, A.
    Goldwasser, F.
    Tod, M.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 49 (04) : 1109 - 1114
  • [7] The Development and Validation of a Simple HPLC-UV Method for the Determination of Vancomycin Concentration in Human Plasma and Application in Critically Ill Patients
    Aboelezz, Asma
    Tesfamariam, Novel Solomon
    Kharouba, Maged
    Gligoric, Tamara
    Mahmoud, Sherif Hanafy
    MOLECULES, 2025, 30 (05):
  • [8] A Simple and Sensitive HPLC-UV Method for the Determination of Swainsonine in Rat Plasma and its Application in a Pharmacokinetic Study
    Li, D. -L.
    Dong, C. -Y.
    Gao, Y.
    ARZNEIMITTELFORSCHUNG-DRUG RESEARCH, 2012, 62 (05): : 209 - 212
  • [9] A simple and sensitive HPLC-UV method for the determination of ponicidin in rat plasma and its application in a pharmacokinetic study
    Li, Xiaotian
    Hou, Wenjing
    Song, Jingjing
    Liu, Hongmin
    Song, Shumei
    Zhang, Lingchun
    Shi, Yingying
    BIOMEDICAL CHROMATOGRAPHY, 2011, 25 (03) : 362 - 366
  • [10] A simple sample preparation with HPLC-UV method for estimation of tiropramide from plasma: Application to bioequivalence study
    Imran, Khan
    Punnamchand, Loya
    Natvarlal, Saraf Madhusudan
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (03) : 1135 - 1140