Influence of Planar Mirror Confinement and Temperature Control upon the Elemental Analysis of Soil by Laser-Induced Breakdown Spectroscopy

被引:8
|
作者
Meng, Yan [1 ,2 ,3 ]
Li, Honglian [1 ,2 ,3 ,4 ]
Wang, Yitong [1 ,2 ,3 ]
Lv, Heshuai [1 ,2 ,3 ]
Wang, Chun [1 ,2 ,3 ]
Wang, Fan [1 ,2 ,3 ]
Fang, Lide [1 ,2 ,3 ]
机构
[1] Hebei Univ, Sch Qual & Tech Supervis, Baoding, Peoples R China
[2] Natl & Local Joint Engn Res Ctr Metrol Instrument, Baoding, Hebei, Peoples R China
[3] Hebei Univ, Hebei Key Lab Energy Metering & Safety Testing Tec, Baoding, Hebei, Peoples R China
[4] Hebei Univ, 2666 Qiyi East Rd, Baoding 071002, Hebei, Peoples R China
基金
中国国家自然科学基金;
关键词
Elemental analysis; heavy metal; laser-induced breakdown spectroscopy; planar mirror constraint; soil; SPATIAL CONFINEMENT; SAMPLE TEMPERATURE; ENHANCEMENT; PLASMA;
D O I
10.1080/00032719.2023.2185250
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
To improve the signal-to-noise ratio of laser-induced breakdown spectroscopy, an enhancement combining planar mirror constraint and temperature control is reported. Theoretical analysis of planar mirror constraint and temperature control reveals that the interaction of the two mechanisms further enhances the spectral response. The spectral intensities and signal-to-noise ratios of samples with and without the enhancements were compared. The results showed that the enhancement factors for Cd, Fe, Al, and Pb were 2.50, 2.78, 2.66, and 2.47, respectively. The corresponding signal-to-noise ratio enhancement factors were 1.83, 2.11, 1.98, and 1.91. The coefficients of determination R-2 for Cd and Pb were 0.912 and 0.962 without enhancement but were 0.969 and 0.990 with the dual mechanism. The limits of detection for Cd and Pb were 74.6 mg/kg and 62.3 mg/kg without enhancement but were 58.4 mg/kg and 46.7 mg/kg with the dual mechanism. This study shows that the enhancement with planar mirror constraint and temperature control improved the signal-to-noise ratio and accuracy.
引用
收藏
页码:2792 / 2802
页数:11
相关论文
共 50 条
  • [31] Effect of distances between lens and sample surface on laser-induced breakdown spectroscopy with spatial confinement
    Jiang, Zhenhua
    Shao, Junfeng
    Wang, Tingfeng
    Guo, Jin
    Zhang, Dan
    Chen, Anmin
    Jin, Mingxing
    PLASMA SCIENCE & TECHNOLOGY, 2018, 20 (08)
  • [32] Effect of cylindrical cavity height on laser-induced breakdown spectroscopy with spatial confinement
    Shao, Junfeng
    Wang, Tingfeng
    Guo, Jin
    Chen, Anmin
    Jin, Mingxing
    PLASMA SCIENCE & TECHNOLOGY, 2017, 19 (02)
  • [33] Correction and analysis of lead content in soil by laser-induced breakdown spectroscopy
    谢承利
    陆继东
    李鹏艳
    李捷
    林兆祥
    ChineseOpticsLetters, 2009, 7 (06) : 545 - 548
  • [34] Analysis of lead and copper in soil samples by laser-induced breakdown spectroscopy under external magnetic field
    Akhtar, M.
    Jabbar, A.
    Ahmed, N.
    Mahmood, S.
    Umar, Z. A.
    Ahmed, R.
    Baig, M. A.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2019, 125 (06):
  • [35] Application of Stand-off Double-Pulse Laser-Induced Breakdown Spectroscopy in Elemental Analysis of Magnesium Alloy
    Qi Lifeng
    Sun Lanxiang
    Xin Yong
    Cong Zhibo
    Li Yang
    Yu Haibin
    PLASMA SCIENCE & TECHNOLOGY, 2015, 17 (08) : 676 - 681
  • [36] Progress of Chemometrics in Laser-induced Breakdown Spectroscopy Analysis
    Zhang Tian-Long
    Wu Shan
    Tang Hong-Sheng
    Wang Kang
    Duan Yi-Xiang
    Li Hua
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (06) : 939 - 948
  • [37] Comparison of sample temperature effect on femtosecond and nanosecond laser-induced breakdown spectroscopy
    LIU, Miao
    CHEN, Anmin
    CHEN, Yutong
    ZENG, Xiangyu
    WANG, Qiuyun
    ZHANG, Dan
    YANG, Dapeng
    JIN, Mingxing
    PLASMA SCIENCE & TECHNOLOGY, 2021, 23 (07)
  • [38] Characterization and forensic analysis of soil samples using laser-induced breakdown spectroscopy (LIBS)
    Sarah C. Jantzi
    José R. Almirall
    Analytical and Bioanalytical Chemistry, 2011, 400 : 3341 - 3351
  • [39] Laser-Induced Breakdown Spectroscopy for Simultaneous Quantitative Analysis of Multi-Elements in Soil
    Yu Ke-qiang
    Zhao Yan-ru
    Liu Fei
    He Yong
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37 (09) : 2879 - 2884
  • [40] Calibration-free laser-induced breakdown spectroscopy for quantitative elemental analysis of materials
    Unnikrishnan, V. K.
    Mridul, K.
    Nayak, R.
    Alti, K.
    Kartha, V. B.
    Santhosh, C.
    Gupta, G. P.
    Suri, B. M.
    PRAMANA-JOURNAL OF PHYSICS, 2012, 79 (02): : 299 - 310