Selective laser trabeculoplasty as adjunctive treatment for open-angle glaucoma vs following incisional glaucoma surgery in Chinese eyes

被引:0
作者
Zhu, Jing [1 ]
Guo, Juan [1 ,2 ]
机构
[1] Chongqing Med Univ 2, Southwest Jiao Tong Univ, Peoples Hosp Chengdu 3, Dept Ophthalmol,Affiliated Hosp,Affiliated Chengdu, Chengdu 610031, Sichuan, Peoples R China
[2] Chongqing Med Univ 2, Southwest Jiao Tong Univ, Peoples Hosp Chengdu 3, Dept Ophthalmol,Affiliated Hosp,Affiliated Chengdu, 82,Qing Long St, Chengdu 610031, Sichuan, Peoples R China
关键词
Selective laser trabeculoplasty; Open-angle glaucoma; Intraocular pressure; Prior glaucoma surgery; Adjunctive treatment; LONG-TERM OUTCOMES; EFFICACY;
D O I
10.12998/wjcc.v11.i4.780
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Selective laser trabeculoplasty (SLT) is a relatively safe and effective therapy in lowering intraocular pressures (IOP) for glaucoma.AIM To study the long-term effects of SLT on IOP and number of glaucoma medications used in Chinese eyes.METHODS This is a retrospective study in which 75 eyes of 70 patients with open-angle glaucoma (OAG, n =36) and eyes with prior glaucoma surgery (PGS, n =39) were included. Changes in mean IOP and number of glaucoma medications used evaluated at 1 d, 1 wk, 1 mo, 3 mo, 6 mo, 12 mo, and 36 mo after laser treatment.RESULTS All patients (33 male, 37 female) were Chinese. The mean age was 44.34 +/- 16.14 years. Mean pre-SLT IOP was 22.75 +/- 2.08 mmHg in OAG and 22.52 +/- 2.62 mmHg in PGS. Mean IOP was significantly reduced 1 d, 1 wk, 1 mo and 3 mo after laser treatment (P < 0.05, respectively). Whereas, there were no significant differences between baseline and SLT treated groups at the 6(th) month both in OAG (P = 0.347, P > 0.05) and in PGS (P = 0.309, P > 0.05). Six months after SLT treatment, some patients received retreatment of SLT or were given more topical IOP-lowering medication to control the IOP. By the end of our study, the average IOP decreased to 20.73 +/- 1.82 mmHg in OAG and 20.49 +/- 1.53 mmHg in PGS groups. The number of glaucoma medications used was significantly reduced until the end of 3 years compared to baseline. CONCLUSIONSLT could reduce IOP as adjunctive treatment both in OAG and PGS groups. SLT significantly reduced the number of glaucoma medications used 3-years following treatment in glaucoma patients.
引用
收藏
页码:780 / 787
页数:8
相关论文
共 19 条
  • [1] Selective laser trabeculoplasty versus topical medication as initial glaucoma treatment: the glaucoma initial treatment study randomised clinical trial
    Ang, Ghee Soon
    Fenwick, Eva K.
    Constantinou, Marios
    Gan, Alfred Tau Liang
    Man, Ryan Eyn Kidd
    Casson, Robert J.
    Finkelstein, Eric A.
    Goldberg, Ivan
    Healey, Paul R.
    Pesudovs, Konrad
    Sanmugasundram, Sutha
    Xie, Jing
    McIntosh, Rachel
    Jackson, Jonathan
    Wells, Anthony
    White, Andrew
    Martin, Keith
    Walland, Mark J.
    Crowston, Jonathan G.
    Lamoureux, Ecosse Luc
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2020, 104 (06) : 813 - 821
  • [2] Apolostolski S, 1987, Neurologija, V36, P41
  • [3] Long term effects on the lowering of intraocular pressure: selective laser or argon laser trabeculoplasty?
    Bovell, Amy M.
    Damji, Karim F.
    Hodge, William G.
    Rock, William J.
    Buhrmann, Ralf R.
    Pan, Yi I.
    [J]. CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2011, 46 (05): : 408 - 413
  • [4] Repeatability of selective laser trabeculoplasty for open-angle glaucoma
    Francis, Brian A.
    Loewen, Nils
    Hong, Bryan
    Dustin, Laurie
    Kaplowitz, Kevin
    Kinast, Robert
    Bacharach, Jason
    Radhakrishnan, Sunita
    Iwach, Andrew
    Rudavska, Lidiya
    Ichhpujani, Parul
    Katz, L. Jay
    [J]. BMC OPHTHALMOLOGY, 2016, 16
  • [5] Selective laser trabeculoplasty versus drops for newly diagnosed ocular hypertension and glaucoma: the LiGHT RCT
    Gazzard, Gus
    Konstantakopoulou, Evgenia
    Garway-Heath, David
    Garg, Anurag
    Vickerstaff, Victoria
    Hunter, Rachael
    Ambler, Gareth
    Bunce, Catey
    Wormald, Richard
    Nathwani, Neil
    Barton, Keith
    Rubin, Gary
    Morris, Stephen
    Buszewicz, Marta
    [J]. HEALTH TECHNOLOGY ASSESSMENT, 2019, 23 (31) : 1 - +
  • [6] Long-term follow-up of selective laser trabeculoplasty in primary open-angle glaucoma
    Gracner, T.
    Falez, M.
    Gracner, B.
    Pahor, D.
    [J]. KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2006, 223 (09) : 743 - 747
  • [7] Comparison of long-term outcomes of selective laser trabeculoplasty versus argon laser trabeculoplasty in open-angle glaucoma
    Juzych, MS
    Chopra, V
    Banitt, MR
    Hughes, BA
    Kim, C
    Goulas, MT
    Shin, DH
    [J]. OPHTHALMOLOGY, 2004, 111 (10) : 1853 - 1859
  • [8] A Novel Method for Quantifying the Amount of Trabecular Meshwork Pigment in Glaucomatous and Nonglaucomatous Eyes
    Kinori, Michael
    Hostovsky, Avner
    Skaat, Alon
    Schwartsman, Jonathan
    Melamed, Shlomo
    [J]. JOURNAL OF GLAUCOMA, 2014, 23 (01) : E13 - E17
  • [9] SELECTIVE TARGETING OF TRABECULAR MESHWORK CELLS - IN-VITRO STUDIES OF PULSED AND CW LASER INTERACTIONS
    LATINA, MA
    PARK, C
    [J]. EXPERIMENTAL EYE RESEARCH, 1995, 60 (04) : 359 - 371
  • [10] Latina Mark A, 2002, Curr Opin Ophthalmol, V13, P94, DOI 10.1097/00055735-200204000-00007