The use of the femoral neck system (FNS) leads to better outcomes in the surgical management of femoral neck fractures in adults compared to fixation with cannulated screws: A systematic review and meta-analysis

被引:11
|
作者
Patel, Sandeep [1 ]
Kumar, Vishal [1 ]
Baburaj, Vishnu [1 ]
Dhillon, Mandeep Singh [1 ]
机构
[1] Postgrad Inst Med Educ & Res, Dept Orthopaed, Chandigarh, India
来源
EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY | 2023年 / 33卷 / 05期
关键词
Femoral neck system; Femoral neck fracture; Cannulated screws; FNS; CCS; Systematic review; Meta-analysis; HIP SCREW;
D O I
10.1007/s00590-022-03407-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Intracapsular femoral neck fractures are challenging to treat, with outcomes depending on the quality of reduction, and the stability of fixation. Cannulated cancellous screws (CCS) are the most commonly used implants to fix these fractures, but failure rates are significant. The recently introduced femoral neck system (FNS) may be a better option than CCS fixation and this review attempts to compare the results. Methods Four electronic databases were searched for eligible articles that had comparative data on the outcomes of fixation of adult femoral neck fractures with FNS and CCS. Data on various outcome parameters were collected. Meta-analysis was conducted using a random-effects model with 95% confidence intervals. Results Eight studies with 509 cases having a mean age of 50.8 years were included for final analysis. FNS was found to be associated with significantly reduced complication rates (p < 0.001), decreased incidence of postoperative femoral neck shortening (p < 0.001), quicker time to fracture union (p = 0.002), and better functional outcome scores (p < 0.001) compared to cannulated screws. FNS was also associated with a shorter operating time (mean difference 6.65 min) although not statistically significant (p = 0.24). CCS group had significantly reduced mean blood loss (p < 0.001). Conclusion The available literature supports FNS as a better option for adult femoral neck fractures, with a lower complication rate, quicker union, and better clinical outcomes. Level of evidence: Level 3.
引用
收藏
页码:2101 / 2109
页数:9
相关论文
共 50 条
  • [31] Femoral neck system versus multiple cannulated screws for the fixation of Pauwels classification type II femoral neck fractures in older female patients with low bone mass
    Yeoh, Soon-Chin
    Wu, Wen-Tien
    Peng, Cheng-Huan
    Yao, Ting-Kuo
    Chang, Chia-Ming
    Liu, Kuan-Lin
    Yu, Tzai-Chiu
    Chen, Ing-Ho
    Wang, Jen-Hung
    Yeh, Kuang-Ting
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [32] Femoral neck system versus multiple cannulated screws for the fixation of Pauwels classification type II femoral neck fractures in older female patients with low bone mass
    Soon-Chin Yeoh
    Wen-Tien Wu
    Cheng-Huan Peng
    Ting-Kuo Yao
    Chia-Ming Chang
    Kuan-Lin Liu
    Tzai-Chiu Yu
    Ing-Ho Chen
    Jen-Hung Wang
    Kuang-Ting Yeh
    BMC Musculoskeletal Disorders, 25
  • [33] Internal Fixation Versus Arthroplasty for the Treatment of Nondisplaced Femoral Neck Fractures in the Elderly: A Systematic Review and Meta-Analysis
    Richards, John T.
    Overmann, Archie L.
    O'Hara, Nathan N.
    D'Alleyrand, Jean-Claude
    Slobogean, Gerard P.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2020, 34 (01) : 42 - 48
  • [34] Robot-assisted vs freehand cannulated screw placement in femoral neck fractures surgery A systematic review and meta-analysis
    Zheng, Yongshun
    Yang, Jiazhao
    Zhang, Fan
    Lu, Jinsen
    Qian, Yeben
    MEDICINE, 2021, 100 (20) : E25926
  • [35] Comparison of femoral neck system and three cannulated cancellous screws in the treatment of vertical femoral neck fractures: clinical observation and finite element analysis
    Huang, Shaolong
    Zhang, Yazhong
    Zhang, Xu
    Zhou, Chengqiang
    Li, Wenbo
    Wang, Yunqing
    Wang, Bin
    Zhu, Ziqiang
    BIOMEDICAL ENGINEERING ONLINE, 2023, 22 (01)
  • [36] Bio-mechanical effects of femoral neck system versus cannulated screws on treating young patients with Pauwels type III femoral neck fractures: a finite element analysis
    Fan, Xiao
    Zhou, Yimin
    Dai, Shiyou
    Lao, Kecheng
    Zhang, Qiliang
    Yu, Tengbo
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [37] Comparison of femoral neck system and three cannulated cancellous screws in the treatment of vertical femoral neck fractures: clinical observation and finite element analysis
    Shaolong Huang
    Yazhong Zhang
    Xu Zhang
    Chengqiang Zhou
    Wenbo Li
    Yunqing Wang
    Bin Wang
    Ziqiang Zhu
    BioMedical Engineering OnLine, 22
  • [38] Hemiarthroplasty compared to total hip arthroplasty for the treatment of femoral neck fractures: a systematic review and meta-analysis
    Xinbo Li
    Jianning Luo
    Journal of Orthopaedic Surgery and Research, 16
  • [39] Hemiarthroplasty compared to total hip arthroplasty for the treatment of femoral neck fractures: a systematic review and meta-analysis
    Li, Xinbo
    Luo, Jianning
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [40] Treatment of Femoral Neck Fractures in Adults With Improved Biplane Double-Supported Screw Fixation and Femoral Neck System: Complications and Surgical Techniques
    Zhang, Xiaolong
    Feng, Xiwen
    Ouyang, Lingfei
    Shu, Shan
    Zhuang, Lebin
    Gui, Weichao
    Zhang, Sheng
    Yao, Zilong
    Wang, Gang
    Liao, Hua
    Hu, Jijie
    ORTHOPAEDIC SURGERY, 2025,