Effect of PET waste fiber addition on flexural behavior of concrete beams reinforced with GFRP bars

被引:5
作者
Mohammed, Azad A. [1 ]
Muhammad, Muhammad A. [1 ]
Mohammed, Bilal K. [2 ]
机构
[1] Univ Sulaimani, Coll Engn, Civil Engn Dept, Sulaymaniyah, Kurdistan Regio, Iraq
[2] Sulaimani Polytech Univ, Sulaimani Tech Inst, Surveying Dept, Sulaymaniyah, Kurdistan Regio, Iraq
关键词
PET waste fiber addition; Fiber length; GFRP reinforced concrete beam; Flexural behavior; Compressive stress-strain curve; Split tensile stress-strain response;
D O I
10.1016/j.cscm.2023.e02564
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper aims to experimentally investigate the flexural behavior of concrete beams reinforced with glass fiber reinforced polymer (GFRP) bars made of concrete with and without polyethylene terephthalate (PET) waste fiber addition. The test variable covers the structural application of different PET fiber lengths (20 mm and 40 mm). Firstly, several tests were done on ten concrete mixes containing 1-2% PET waste fiber with a 0.25% increment by volume. The mixture's concrete properties, including stress-strain curves, were studied to obtain the optimum percent-age of PET fiber. Furthermore, four GFRP reinforced concrete (RC) beams were cast from concrete containing 0% PET fiber (the control beam), 1% PET fiber volumes of 20 mm and 40 mm, and an equal mixture of both lengths. The beams were designed using ACI 440.1R to fail in GFRP rupture. The results showed that compressive strength increased by 8% and 6% using 1% fiber volume of 20 and 40 mm PET fiber, respectively. It was found that PET fiber addition had a negligible effect on changing the ductility, cracking pattern, or failure mode of under reinforced GFRP RC beams. The cracking and ultimate loads are slightly reduced, however, and the corre-sponding deflections are well reduced, especially when using 40 mm PET fiber. With the use of PET waste fiber, serviceability increased by up to 12% based on deflection limit control (L/240). The addition of 40 mm of PET fiber was found to enhance the beam stiffness by 25%. An analysis method has been proposed to predict the flexural strength of GFRP RC beams made with PET fiber. Moreover, it is recommended to treat the PET fiber surface to improve the fiber-concrete bond when used in non-ductile RC beams.
引用
收藏
页数:18
相关论文
共 36 条
  • [1] ACI, 2019, ACI 318M
  • [2] ACI, 2022, ACI PRC 211.1Sel
  • [3] Strength behavior of reinforced concrete beam using re-cycle of PET wastes as synthetic fibers
    Adnan, Hamsa M.
    Dawood, Abbas O.
    [J]. CASE STUDIES IN CONSTRUCTION MATERIALS, 2020, 13
  • [4] Al-Hadithi Ismail., 2018, Iraqi J Civil Eng, V12, P110, DOI [10.37650/ijce.2018.142480, DOI 10.37650/IJCE.2018.142480]
  • [5] [Anonymous], 2014, Standard Test Method for Sieve Analysis of Fine and Coarse Aggregates
  • [6] [Anonymous], 2015, 4401R ACI
  • [7] [Anonymous], 2005, Design of steel structures-Part 1.1: General rules and rules for buildings. EN 1993-1-1:2005
  • [8] Two-Way Shear Resistance of FRP Reinforced-Concrete Slabs: Data and a Comparative Study
    Aslam, Fahid
    AbdelMongy, Mohamed
    Alzara, Majed
    Ibrahim, Taha
    Deifalla, Ahmed Farouk
    Yosri, Ahmed M.
    [J]. POLYMERS, 2022, 14 (18)
  • [9] ASTM, 2021, ASTM A370
  • [10] ASTM, 2021, ASTM D7205/D7205M