Fault Clearing Operation in Low-Frequency High-Voltage AC Systems

被引:0
|
作者
Kim, Woosung [1 ]
Nguyen, Quan [2 ]
Santoso, Surya [1 ]
机构
[1] Univ Texas Austin, Austin, TX 78712 USA
[2] Pacific Northwest Natl Lab, Richland, WA USA
关键词
LF-HVac system; BTB converter; fault clearing; fault current;
D O I
10.1109/PESGM52003.2023.10252479
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Low-frequency high-voltage ac (LF-HVac) system has been proposed as an alternative to HVdc and HVac systems for long-distance bulk power transmission. LF-HVac system employs back-to-back (BTB) converters to interconnect and control voltage and power interchange between two asynchronous power grids operating at different frequencies. While there are multiple studies on LF-HVac system available in the literature, fault clearing operation has not been analyzed. Therefore, this paper focuses on fault clearing operation in the LF-HVac system and proposes a novel method to reduce fault current by changing operating frequency of power source and converter during the fault condition. The performance of the proposed method is validated using detailed models of BTB converters developed in PSCAD/EMTDC. The ability to change operating frequency at the onset of a fault condition allows breakers to rapidly clear the fault and recloses. The results obtained using the proposed method substantially diminish the fault current.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Voltage Stability of Low Frequency AC Transmission Systems
    Tuan Ngo
    Quan Nguyen
    Santoso, Surya
    2016 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION (T&D), 2016,
  • [22] Adapted Technique for Calibrating Voltage Dividers of AC High-Voltage Measuring Systems
    Hala M. Abdel Mageed
    Rehab S. Salah Eldeen
    MAPAN, 2020, 35 : 11 - 17
  • [23] Adapted Technique for Calibrating Voltage Dividers of AC High-Voltage Measuring Systems
    Mageed, Hala M. Abdel
    Eldeen, Rehab S. Salah
    MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2020, 35 (01): : 11 - 17
  • [24] Arc fault model for low-voltage AC systems
    Wu, HR
    Li, XH
    Stade, D
    Schau, H
    IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (02) : 1204 - 1205
  • [25] Damping low-frequency oscillation in AC/DC power systems based on multi-operation modes
    Ma Yanfeng
    Zhao Shuqiang
    Gu Xueping
    2006 INTERNATIONAL CONFERENCE ON POWER SYSTEMS TECHNOLOGY: POWERCON, VOLS 1- 6, 2006, : 318 - +
  • [26] HIGH-VOLTAGE MEDIUM(LOW)-VOLTAGE SUBSTATION EARTHING SYSTEMS
    NAHMAN, J
    JELOVAC, D
    IEE PROCEEDINGS-C GENERATION TRANSMISSION AND DISTRIBUTION, 1987, 134 (01) : 75 - 80
  • [27] Low-frequency AC electrokinetics
    Pengra, DB
    Wong, PZ
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 1999, 159 (2-3) : 283 - 292
  • [28] Comparison of high-voltage ac and pulsed operation of a surface dielectric barrier discharge
    Williamson, James M.
    Trump, Darryl D.
    Bletzinger, Peter
    Ganguly, Biswa N.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2006, 39 (20) : 4400 - 4406
  • [29] MEASUREMENT OF FREQUENCY AND VOLTAGE OF LOW-POWER, HIGH-VOLTAGE SOURCES
    DZHAGUPOV, RG
    RAGOZIN, YS
    MEASUREMENT TECHNIQUES-USSR, 1970, (02): : 312 - +
  • [30] Low-Frequency Noise in Thick-Film Resistors Due to Laser and High-Voltage Pulse Trimming
    Stanimirovic, Ivanka
    Stanimirovic, Zdravko
    2018 41ST INTERNATIONAL SPRING SEMINAR ON ELECTRONICS TECHNOLOGY (ISSE), 2018,