Minimum 25-Year Results of a Tapered Titanium Porous Plasma Spray Coated Femoral Component

被引:4
作者
Alexander, Jacob S. [1 ]
Lombardi Jr, Adolph V. [1 ]
Berend, Keith R. [1 ]
Houserman, David J. [1 ]
Adams, Joanne B. [1 ]
Crawford, David A. [1 ]
机构
[1] JIS Orthoped, New Albany, OH 43054 USA
关键词
total hip arthroplasty; implant; survival; cementless; taper; TOTAL HIP-ARTHROPLASTY; FOLLOW-UP; SURVIVORSHIP; PROSTHESIS; SURVIVAL;
D O I
10.1016/j.arth.2023.03.021
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Previous studies have reported excellent results with tapered, titanium, porous plasma -sprayed components in patients undergoing uncemented primary total hip arthroplasty (THA). The purpose of this study was to examine survival and clinical results at a minimum 25-year follow-up.Methods: We reviewed all patients who underwent primary THA at our center through 1995 with a specific femoral component that was essentially unchanged since its 1984 introduction, except porous coating was continued circumferentially in 1987, a hydroxyapatite-coated option was offered in 1988, and an offset option was added in 1999. There were 332 patients (396 THA) who had a minimum 25-year follow-up (range, 25 to 37). Mean age at surgery was 48 years (range, 21 to 70 years). Mean follow-up in nonfailed patients was 29 years (range, 25 to 37 years).Results: There were 31 femoral revisions (7.8%): 9 infections, 3 failures of ingrowth, 5 aseptic loosening, 8 osteolysis well-fixed, 2 periprosthetic fractures, 2 polyethylene wear with trochanteric avulsion, 1 component breakage, and 1 malalignment well-fixed. Kaplan-Meier survival with the endpoint of all -cause stem revision was 94.8% (95% confidence interval: & PLUSMN;0.9%) at 37 years, and with the endpoint of aseptic loosening/failure of ingrowth was 98.7% (95% confidence interval: & PLUSMN;0.5) at 37 years. Harris hip scores improved significantly from 43 preoperatively to 76 most recently.Conclusion: This tapered, titanium, porous plasma spray-coated femoral component continues to demonstrate high long-term survival with a low rate of femoral component revision for any reason or aseptic loosening/failure of ingrowth.& COPY; 2023 Elsevier Inc. All rights reserved.
引用
收藏
页码:1802 / 1807
页数:6
相关论文
共 29 条
[1]  
Austin Matthew S, 2012, HSS J, V8, P146, DOI 10.1007/s11420-012-9268-x
[2]   Cernentless double-tapered total hip arthroplasty in patients 75 years of age and older [J].
Berend, KR ;
Lombardi, AV ;
Mallory, TH ;
Dodds, KL ;
Adams, JB .
JOURNAL OF ARTHROPLASTY, 2004, 19 (03) :288-295
[3]   A femoral component inserted without cement in total hip arthroplasty - A study of the Tri-Lock component with an average ten-year duration of follow-up [J].
Burt, CF ;
Garvin, KL ;
Otterberg, ET ;
Jardon, OM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (07) :952-960
[4]   What Works Best, a Cemented or Cementless Primary Total Hip Arthroplasty? Minimum 17-year Followup of a Randomized Controlled Trial [J].
Corten, Kristoff ;
Bourne, Robert B. ;
Charron, Kory D. ;
Au, Keegan ;
Rorabeck, Cecil H. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (01) :209-217
[5]   Tapered titanium porous plasma-sprayed femoral component in patients aged 40 years and younger [J].
Ellison, Brad ;
Berend, Keith R. ;
Lombardi, Adolph V., Jr. ;
Mallory, Thomas H. .
JOURNAL OF ARTHROPLASTY, 2006, 21 (06) :32-37
[6]   Minimal stress shielding with a Mallory-Head titanium femoral stem with proximal porous coating in total hip arthroplasty [J].
Ellison B. ;
Cheney N.A. ;
Berend K.R. ;
Lombardi Jr. A.V. ;
Mallory T.H. .
Journal of Orthopaedic Surgery and Research, 4 (1)
[7]   Effect of circumferential plasma-spray porous coating on the rate of femoral osteolysis after total hip arthroplasty [J].
Emerson, RH ;
Sanders, SB ;
Head, WC ;
Higgins, L .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (09) :1291-1298
[8]   EVALUATION OF BONE INGROWTH IN PROXIMALLY AND EXTENSIVELY POROUS-COATED ANATOMIC MEDULLARY LOCKING PROSTHESES RETRIEVED AT AUTOPSY [J].
ENGH, CA ;
HOOTEN, JP ;
ZETTLSCHAFFER, KF ;
GHAFFARPOUR, M ;
MCGOVERN, TF ;
BOBYN, JD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (06) :903-910
[9]   On the design evolution of hip implants: A review [J].
Guo, Liyao ;
Naghavi, Seyed Ataollah ;
Wang, Ziqiang ;
Varma, Swastina Nath ;
Han, Zhiwu ;
Yao, Zhongwen ;
Wang, Ling ;
Wang, Liqiang ;
Liu, Chaozong .
MATERIALS & DESIGN, 2022, 216
[10]   What Is the Risk of Revision Surgery in Hydroxyapatite-coated Femoral Hip Stems? Findings From a Large National Registry [J].
Inacio, Maria C. ;
Lorimer, Michelle ;
Davidson, David C. ;
De Steiger, Richard N. ;
Lewis, Peter L. ;
Graves, Stephen E. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2018, 476 (12) :2353-2366