Estimation of Position and Shorted Turns Percentage of an Inter-Turn Short Circuit in Interior Permanent Magnet Synchronous Machines Based on a Current Observer and Stationary Reference Frame Tracking

被引:8
作者
Palavicino, Pablo Castro [1 ]
Sarlioglu, Bulent [1 ]
机构
[1] Univ Wisconsin, Dept Elect & Comp Engn, Madison, WI 53706 USA
关键词
AC machines; electrical fault detection; machine controls; observer; permanent magnet machines; FAULT-DIAGNOSIS; INSULATION; STRATEGY; VECTOR;
D O I
10.1109/TIA.2023.3268996
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper presents a method to detect and diagnose an inter-turn short circuit in interior permanent magnet synchronous machines. The proposed method detects the inter-turn short circuit fault using a current observer to estimate a disturbance related to the fault, defined as a fault index current. The fault index current estimates in the rotor reference frame have information about the location and the percentage of shorted turns. A novel stationary frame tracking technique is proposed to simultaneously determine the fault index current in the stationary frame and the fault position. Look-up tables are implemented to correlate the stationary frame fault index current magnitude to the percentage of shorted turns, providing an estimate of the percentage of shorted turns. Simulation and experimental results are shown throughout the paper to analyze and validate the proposed technique.
引用
收藏
页码:4066 / 4075
页数:10
相关论文
共 33 条
[1]  
Alvarez-Gonzalez F, 2018, IEEE IND ELEC, P647, DOI 10.1109/IECON.2018.8591661
[2]   Evaluation of saliency tracking as an alternative for health monitoring in PMSM-drives under non-stationary conditions [J].
Arellano-Padilla, Jesus ;
Sumner, Mark ;
Gerada, Chris .
IET ELECTRIC POWER APPLICATIONS, 2016, 10 (04) :284-293
[3]  
Bao JQ, 2019, 2019 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (ICMA), P993, DOI [10.1109/ICMA.2019.8816198, 10.1109/icma.2019.8816198]
[4]  
Blasko V, 1996, IEEE POWER ELECTRON, P1872, DOI 10.1109/PESC.1996.548836
[5]   Increased efficiency versus increased reliability - A comparison of pre-EPAct, EPAct, and premium-efficient motors [J].
Bonnett, Austin H. ;
Yung, Chuck .
IEEE INDUSTRY APPLICATIONS MAGAZINE, 2008, 14 (01) :29-36
[6]   Analysis and compensation of current measurement error in vector-controlled AC motor drives [J].
Chung, DW ;
Sul, SK .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1998, 34 (02) :340-345
[7]   Mitigation of Turn-to-Turn Faults in Fault Tolerant Permanent Magnet Synchronous Motors [J].
Cintron-Rivera, Jorge G. ;
Foste, Shanelle N. ;
Strangas, Elias G. .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2015, 30 (02) :465-475
[8]   Motor winding problems - Caused by inverter drives [J].
Fenger, M ;
Campbell, SR ;
Pedersen, J .
IEEE INDUSTRY APPLICATIONS MAGAZINE, 2003, 9 (04) :22-31
[9]   Recent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors [J].
Gandhi, Arun ;
Corrigan, Timothy ;
Parsa, Leila .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (05) :1564-1575