Development of Pipetteless Paper-Based Analytical Devices with a Volume Gauge

被引:7
作者
Danchana, Kaewta [1 ]
Iwasaki, Hiroshi [1 ]
Thayawutthikun, Yada [2 ,3 ,4 ]
Saetear, Phoonthawee [2 ,3 ,4 ]
Kaneta, Takashi [1 ]
机构
[1] Okayama Univ, Dept Chem, Okayama 7008530, Japan
[2] Mahidol Univ, Flow Innovat Res Sci & Technol Labs FIRST Labs, Bangkok 10400, Thailand
[3] Mahidol Univ, Fac Sci, Dept Chem, Bangkok 10400, Thailand
[4] Mahidol Univ, Fac Sci, Ctr Excellence Innovat Chem, Bangkok 10400, Thailand
关键词
PAD; SAMPLE;
D O I
10.1021/acsomega.2c08138
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this work, we propose a new design for paper based analytical devices (PADs) that eliminate the need to use a micropipette for sample introduction. With this design, a PAD is equipped with a distance-based detection channel that is connected to a storage channel that indicates the volume of a sample introduced into the PAD. The analyte in the sample solution reacts with a colorimetric reagent deposited into the distance-based detection channel as the sample solution flows into the storage channel where the volume is measured. The ratio of the lengths of the detection channel and that of the storage channel (D/S ratio) are constant for a sample containing a certain concentration, which is independent of the introduced volume. Therefore, the PADs permit volume-independent quantification using a dropper instead of a micropipette because the length of the storage channel plays the role of a volume gauge to estimate the introduced sample volume. In this study, the D/S ratios obtained with a dropper were comparable to those obtained with a micropipette, which confirmed that precise volume control is unnecessary for this PAD system. The proposed PADs were applied to the determinations of iron and bovine serum albumin using bathophenanthroline and tetrabromophenol blue as colorimetric reagents, respectively. The calibration curves showed good linear relationships with coefficients of 0.989 for iron and 0.994 for bovine serum albumin, respectively.
引用
收藏
页码:11213 / 11219
页数:7
相关论文
共 34 条
[1]  
Abramoff M D., 2004, Biophoton. Int, V11, P36
[2]   Development of a Quasi-Steady Flow Electrochemical Paper-Based Analytical Device [J].
Adkins, Jaclyn A. ;
Noviana, Eka ;
Henry, Charles S. .
ANALYTICAL CHEMISTRY, 2016, 88 (21) :10639-10647
[3]   A colorimetric paper-based analytical device coupled with hollow fiber membrane liquid phase microextraction (HF-LPME) for highly sensitive detection of hexavalent chromium in water samples [J].
Alahmad, Waleed ;
Tungkijanansin, Nuttanee ;
Kaneta, Takashi ;
Varanusupakul, Pakorn .
TALANTA, 2018, 190 :78-84
[4]  
Alahmad W, 2016, ANAL METHODS-UK, V8, P5414, DOI [10.1039/C6AY00954A, 10.1039/c6ay00954a]
[5]   Smartphone and Paper-Based Fluorescence Reader: A Do It Yourself Approach [J].
Alejandra Ireta-Munoz, Laura ;
Morales-Narvaez, Eden .
BIOSENSORS-BASEL, 2020, 10 (06)
[6]   Submicromolar quantification of pyocyanin in complex biological fluids using pad-printed carbon electrodes [J].
Burkitt, Richard ;
Sharp, Duncan .
ELECTROCHEMISTRY COMMUNICATIONS, 2017, 78 :43-46
[7]   Two-ply channels for faster wicking in paper-based microfluidic devices [J].
Camplisson, Conor K. ;
Schilling, Kevin M. ;
Pedrotti, William L. ;
Stone, Howard A. ;
Martinez, Andres W. .
LAB ON A CHIP, 2015, 15 (23) :4461-4466
[8]   Multilayered Microfluidic Paper-Based Devices: Characterization, Modeling, and Perspectives [J].
Channon, Robert B. ;
Nguyen, Michael P. ;
Henry, Charles S. ;
Dandy, David S. .
ANALYTICAL CHEMISTRY, 2019, 91 (14) :8966-8972
[9]   Rapid flow in multilayer microfluidic paper-based analytical devices [J].
Channon, Robert B. ;
Nguyen, Michael P. ;
Scorzelli, Alexis G. ;
Henry, Elijah M. ;
Volckens, John ;
Dandy, David S. ;
Henry, Charles S. .
LAB ON A CHIP, 2018, 18 (05) :793-802
[10]   Determination of glutamate using paper-based microfluidic devices with colorimetric detection for food samples [J].
Danchana, Kaewta ;
Iwasaki, Hiroshi ;
Ochiai, Kenta ;
Namba, Haruka ;
Kaneta, Takashi .
MICROCHEMICAL JOURNAL, 2022, 179