Radiological outcomes of PEEK rods in patients with lumbar degenerative diseases: A minimum 5-year follow-up

被引:3
作者
Huang, Weimin [1 ]
Wang, Wenqiao [1 ]
Xu, Xiaoduo [1 ]
Wang, Lei [1 ]
Wang, Jingming [1 ]
Yu, Xiuchun [1 ]
机构
[1] 960 Hosp Peoples Liberat Army, Orthopaed Dept, Jinan, Peoples R China
来源
FRONTIERS IN SURGERY | 2023年 / 10卷
关键词
PEEK rods; lumbar degenerative diseases; radiological outcomes; rehydration; hybrid; non-fusion; DYNAMIC STABILIZATION; DISC DISTRACTION; SPINE; FUSION; SYSTEM; MULTICENTER; MOTION;
D O I
10.3389/fsurg.2023.1146893
中图分类号
R61 [外科手术学];
学科分类号
摘要
PurposeTo determine the long-term radiological outcomes of PEEK rods in patients with lumbar degenerative diseases. MethodsRadiological outcomes of cohort cases with lumbar degenerative diseases following PEEK rods were retrospectively studied. Disc height index (DHI) and range of motion (ROM) were measured by x-rays. The CT scans and reconstruction were used to determine screw breakage, rods fracture, screw loosening and intervertebral bony fusion status. The MRI scans were used to evaluate the changes of intervertebral discs at the non-fusion segments and adjacent segments in terms of Pfirrmann Classification. ResultsA total of 40 patients completed the mean of 74.8 +/- 9.6 months follow-up, with 32 patients undergoing hybrid surgery and 8 patients undergoing non-fusion surgery. The mean DHI changed from preoperative 0.34 to 0.36 at the final follow-up and the ROM declined from 8.8 degrees preoperatively to 3.2 degrees at the final visit, however, both had no statistical differences. Of the 40 levels underwent non-fusion procedure, 9 levels showed disc rehydration with 7 patients from Grade 4 to Grade 3 and 2 patients from Grade 3 to Grade 2. The other 30 cases did not show distinctive change. No screw loosening or rods breakage were detected during the follow-up periods. ConclusionPEEK rods have obvious protective effects on degenerated intervertebral disc of non-fusion segments and the incidence of complications related to internal fixation is low. PEEK rods pedicle screw system is safe and effective in the treatment of lumbar degenerative diseases.
引用
收藏
页数:7
相关论文
共 50 条
[21]   Non-fusion procedure using PEEK rod systems for lumbar degenerative diseases: clinical experience with a 2-year follow-up [J].
Weimin Huang ;
Zhengqi Chang ;
Ruoxian Song ;
Ke Zhou ;
Xiuchun Yu .
BMC Musculoskeletal Disorders, 17
[22]   Time Course of Radiologic Changes After Lumbar Total Disc Replacement Experience of Single Institute With Minimum 5-Year Follow-up [J].
Hur, Jung-Woo ;
Kim, Jin-Sung ;
Ryu, Kyeong-Sik ;
Shin, Myeong-Hoon ;
Park, Chun-Kun .
CLINICAL SPINE SURGERY, 2018, 31 (05) :E278-E285
[23]   Degenerative cervical spine changes among early career fighter pilots: a 5-year follow-up [J].
Keskimolo, Tuomas ;
Pernu, J. ;
Karppinen, J. ;
Niinimaki, J. ;
Oura, P. ;
Leino, T. ;
Honkanen, T. .
BMJ MILITARY HEALTH, 2023, 169 (04) :291-296
[24]   Comparison of Posterior Lumbar Interbody Fusion and Microendoscopic Muscle-preserving Interlaminar Decompression for Degenerative Lumbar Spondylolisthesis With >5-Year Follow-up [J].
Kimura, Ryota ;
Yoshimoto, Mitsunori ;
Miyakoshi, Naohisa ;
Hongo, Michio ;
Kasukawa, Yuji ;
Kobayashi, Takashi ;
Kikuchi, Kazuma ;
Okuyama, Koichiro ;
Kido, Tadato ;
Hirota, Ryosuke ;
Hamada, Shuto ;
Chiba, Mitsuho ;
Abe, Eiji ;
Yamashita, Toshihiko ;
Shimoda, Yoichi .
CLINICAL SPINE SURGERY, 2019, 32 (08) :E380-E385
[25]   Influence of the Initial Sagittal Lumbar Alignment on Clinical and Radiological Outcomes of Single-Level Lumbar Total Disc Replacements at a Minimum 2-Year Follow-up [J].
Faure, Aymeric ;
Khalife, Marc ;
Thiebaut, Benjamin ;
Roubineau, Francois ;
Lachaniette, Charles-Henri Flouzat ;
Dubory, Arnaud .
SPINE, 2018, 43 (16) :E959-E967
[26]   Adjacent segment disease following lumbar/thoracolumbar fusion with pedicle screw instrumentation - A minimum 5-year follow-up [J].
Cheh, Gene ;
Bridwell, Keith H. ;
Lenke, Lawrence G. ;
Buchowski, Jacob M. ;
Daubs, Michael D. ;
Kim, Yongjung ;
Baldus, Christy .
SPINE, 2007, 32 (20) :2253-2257
[27]   Clinical and Radiological Outcomes of Full-Endoscopic Decompression for Lumbar Spinal Stenosis With Grade I Degenerative Spondylolisthesis: A Retrospective Study With a Minimum 1-Year Follow-up [J].
Choi, Sang-Soo ;
Ahn, Geon ;
Jang, Il-Tae ;
Kim, Hyeun Sung .
NEUROSURGERY PRACTICE, 2024, 5 (01)
[28]   Factors Affecting Clinical Outcomes in Treating Patients With Grade 1 Degenerative Spondylolisthesis Using Interspinous Soft Stabilization With a Tension Band System A Minimum 5-year Follow-up [J].
Lee, Sang-Ho ;
Lee, June-Ho ;
Hong, Soon-Woo ;
Shim, Chan Shik ;
Chung, Seung-Eun ;
Yoo, Seung-Hwa ;
Lee, Ho-Yeon .
SPINE, 2012, 37 (07) :563-572
[29]   Pyrocarbon Metacarpophalangeal Joint Arthroplasty in Noninflammatory Arthritis: Minimum 5-Year Follow-Up [J].
Dickson, David R. ;
Badge, Ravi ;
Nuttall, David ;
Watts, Adam C. ;
Talwalkar, Sumedh C. ;
Hayton, Mike .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (10) :1956-1962
[30]   Application of the Coflex Interlaminar Stabilization in Patients With L5/S1 Degenerative Diseases: Minimum 4-Year Follow-up [J].
Xu, Cong ;
Mao, Fangmin ;
Wang, Xiangyang ;
Lin, Yan ;
Xu, Huazi .
AMERICAN JOURNAL OF THERAPEUTICS, 2016, 23 (06) :E1813-E1818