Radiological outcomes of PEEK rods in patients with lumbar degenerative diseases: A minimum 5-year follow-up

被引:2
|
作者
Huang, Weimin [1 ]
Wang, Wenqiao [1 ]
Xu, Xiaoduo [1 ]
Wang, Lei [1 ]
Wang, Jingming [1 ]
Yu, Xiuchun [1 ]
机构
[1] 960 Hosp Peoples Liberat Army, Orthopaed Dept, Jinan, Peoples R China
来源
FRONTIERS IN SURGERY | 2023年 / 10卷
关键词
PEEK rods; lumbar degenerative diseases; radiological outcomes; rehydration; hybrid; non-fusion; DYNAMIC STABILIZATION; DISC DISTRACTION; SPINE; FUSION; SYSTEM; MULTICENTER; MOTION;
D O I
10.3389/fsurg.2023.1146893
中图分类号
R61 [外科手术学];
学科分类号
摘要
PurposeTo determine the long-term radiological outcomes of PEEK rods in patients with lumbar degenerative diseases. MethodsRadiological outcomes of cohort cases with lumbar degenerative diseases following PEEK rods were retrospectively studied. Disc height index (DHI) and range of motion (ROM) were measured by x-rays. The CT scans and reconstruction were used to determine screw breakage, rods fracture, screw loosening and intervertebral bony fusion status. The MRI scans were used to evaluate the changes of intervertebral discs at the non-fusion segments and adjacent segments in terms of Pfirrmann Classification. ResultsA total of 40 patients completed the mean of 74.8 +/- 9.6 months follow-up, with 32 patients undergoing hybrid surgery and 8 patients undergoing non-fusion surgery. The mean DHI changed from preoperative 0.34 to 0.36 at the final follow-up and the ROM declined from 8.8 degrees preoperatively to 3.2 degrees at the final visit, however, both had no statistical differences. Of the 40 levels underwent non-fusion procedure, 9 levels showed disc rehydration with 7 patients from Grade 4 to Grade 3 and 2 patients from Grade 3 to Grade 2. The other 30 cases did not show distinctive change. No screw loosening or rods breakage were detected during the follow-up periods. ConclusionPEEK rods have obvious protective effects on degenerated intervertebral disc of non-fusion segments and the incidence of complications related to internal fixation is low. PEEK rods pedicle screw system is safe and effective in the treatment of lumbar degenerative diseases.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Hybrid surgery with PEEK rods for lumbar degenerative diseases: a 2-year follow-up study
    Zhao, Yao
    Xu, Beiyu
    Qi, Longtao
    Li, Chunde
    Yue, Lei
    Yu, Zhengrong
    Wang, Shijun
    Sun, Haolin
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [2] Hybrid surgery with PEEK rods for lumbar degenerative diseases: a 2-year follow-up study
    Yao Zhao
    Beiyu Xu
    Longtao Qi
    Chunde Li
    Lei Yue
    Zhengrong Yu
    Shijun Wang
    Haolin Sun
    BMC Musculoskeletal Disorders, 23
  • [3] Non-fusion procedure using PEEK rod systems for lumbar degenerative diseases: clinical experience with a 2-year follow-up
    Huang, Weimin
    Chang, Zhengqi
    Song, Ruoxian
    Zhou, Ke
    Yu, Xiuchun
    BMC MUSCULOSKELETAL DISORDERS, 2016, 17
  • [4] Results of Decompression Alone in Patients with Lumbar Spinal Stenosis and Degenerative Spondylolisthesis: A Minimum 5-Year Follow-up
    Ha, Dae-Ho
    Kim, Tae-Kyun
    Oh, Sung-Kyun
    Cho, Hyung-Gyu
    Kim, Keon-Rok
    Shim, Dae-Moo
    CLINICS IN ORTHOPEDIC SURGERY, 2020, 12 (02) : 187 - 193
  • [5] Clinical and radiological outcomes of dynamic cervical implant arthroplasty: A 5-year follow-up
    Zou, Li
    Rong, Xin
    Liu, Xi-Jiao
    Liu, Hao
    WORLD JOURNAL OF CLINICAL CASES, 2021, 9 (16) : 3869 - 3879
  • [6] Does hybrid fixation prevent junctional disease after posterior fusion for degenerative lumbar disorders? A minimum 5-year follow-up study
    Baioni, Andrea
    Di Silvestre, Mario
    Greggi, Tiziana
    Vommaro, Francesco
    Lolli, Francesco
    Scarale, Antonio
    EUROPEAN SPINE JOURNAL, 2015, 24 : S855 - S864
  • [7] Posterior Dynamic Stabilization in the Treatment of Lumbar Degenerative Disc Disease: 2-Year Follow-Up
    Oktenoglu, T.
    Ozer, A. F.
    Sasani, M.
    Kaner, T.
    Canbulat, N.
    Ercelen, O.
    Sarioglu, A. C.
    MINIMALLY INVASIVE NEUROSURGERY, 2010, 53 (03) : 112 - 116
  • [8] Mean 5-Year Follow-Up Results of a Facet Replacement Device in the Treatment of Lumbar Spinal Stenosis and Degenerative Spondylolisthesis
    Haleem, Shahnawaz
    Ahmed, Awaiz
    Ganesan, Satish
    Stephen, McGillion F.
    Fowler, John L.
    WORLD NEUROSURGERY, 2021, 152 : e645 - e651
  • [9] Increased Proportion of Fusion Surgery for Degenerative Lumbar Spondylolisthesis and Changes in Reoperation Rate A Nationwide Cohort Study With a Minimum 5-Year Follow-up
    Kim, Chi Heon
    Chung, Chun Kee
    Choi, Yunhee
    Kim, Min-Jung
    Kim, Myo Jeong
    Shin, Sukyoun
    Yang, Seung Heon
    Hwang, Sung Hwan
    Kim, Dong Hwan
    Park, Sung Bae
    Lee, Jun Ho
    SPINE, 2019, 44 (05) : 346 - 354
  • [10] Minimum 5 year follow-up of multi-segmental lumbar degenerative disease treated with discectomy and the Wallis interspinous device
    Jiang, Yun-qi
    Che, Wu
    Wang, Hui-ren
    Li, Ruo-yu
    Li, Xi-lei
    Dong, Jian
    JOURNAL OF CLINICAL NEUROSCIENCE, 2015, 22 (07) : 1144 - 1149