Inter-fractional portability of deep learning models for lung target tracking on cine imaging acquired in MRI-guided radiotherapy

被引:1
作者
Peng, Jiayuan [1 ,2 ,3 ,4 ]
Stowe, Hayley B. [2 ]
Samson, Pamela P. [2 ]
Robinson, Clifford G. [2 ]
Yang, Cui [3 ,4 ]
Hu, Weigang [3 ,4 ]
Zhang, Zhen [3 ,4 ]
Kim, Taeho [2 ]
Hugo, Geoffrey D. [2 ]
Mazur, Thomas R. [2 ]
Cai, Bin [2 ,5 ]
机构
[1] Fudan Univ, Acad Engn & Technol, Shanghai, Peoples R China
[2] Washington Univ, Dept Radiat Oncol, St Louis, MO 63110 USA
[3] Fudan Univ, Shanghai Canc Ctr, Dept Radiat Oncol, Shanghai, Peoples R China
[4] Fudan Univ, Shanghai Med Coll, Dept Oncol, Shanghai, Peoples R China
[5] Univ Texas Southwestern Med Ctr, Dept Radiat Oncol, Div Med Phys & Engn, Dallas, TX 75390 USA
关键词
MRI-guided radiotherapy; MRgRT; Tumor tracking; Artificial intelligence; Adaptive training; MOTION; REGISTRATION;
D O I
10.1007/s13246-023-01371-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
MRI-guided radiotherapy systems enable beam gating by tracking the target on planar, two-dimensional cine images acquired during treatment. This study aims to evaluate how deep-learning (DL) models for target tracking that are trained on data from one fraction can be translated to subsequent fractions. Cine images were acquired for six patients treated on an MRI-guided radiotherapy platform (MRIdian, Viewray Inc.) with an onboard 0.35 T MRI scanner. Three DL models (U-net, attention U-net and nested U-net) for target tracking were trained using two training strategies: (1) uniform training using data obtained only from the first fraction with testing performed on data from subsequent fractions and (2) adaptive training in which training was updated each fraction by adding 20 samples from the current fraction with testing performed on the remaining images from that fraction. Tracking performance was compared between algorithms, models and training strategies by evaluating the Dice similarity coefficient (DSC) and 95% Hausdorff Distance (HD95) between automatically generated and manually specified contours. The mean DSC for all six patients in comparing manual contours and contours generated by the onboard algorithm (OBT) were 0.68 +/- 0.16. Compared to OBT, the DSC values improved 17.0 - 19.3% for the three DL models with uniform training, and 24.7 - 25.7% for the models based on adaptive training. The HD95 values improved 50.6 - 54.5% for the models based on adaptive training. DL-based techniques achieved better tracking performance than the onboard, registration-based tracking approach. DL-based tracking performance improved when implementing an adaptive strategy that augments training data fraction-by-fraction.
引用
收藏
页码:769 / 777
页数:9
相关论文
共 17 条
[1]  
Abdeltawab H, 2020, COMPUT MED IMAG GRAP, V81, DOI [10.1016/j.compmedimg.2020.101717, 10.1016/j.compmedimag.2020.101717]
[2]   A deep learning approach for real time prostate segmentation in freehand ultrasound guided biopsy [J].
Abu Anas, Emran Mohammad ;
Mousavi, Parvin ;
Abolmaesumi, Purang .
MEDICAL IMAGE ANALYSIS, 2018, 48 :107-116
[3]  
Cardenas Alex, 2004, J Appl Clin Med Phys, V5, P55, DOI 10.1120/jacmp.2021.25276
[4]   A distance map regularized CNN for cardiac cine MR image segmentation [J].
Dangi, Shusil ;
Linte, Cristian A. ;
Yaniv, Ziv .
MEDICAL PHYSICS, 2019, 46 (12) :5637-5651
[5]   Automatic lung segmentation in routine imaging is primarily a data diversity problem, not a methodology problem [J].
Hofmanninger, Johannes ;
Prayer, Forian ;
Pan, Jeanny ;
Roehrich, Sebastian ;
Prosch, Helmut ;
Langs, Georg .
EUROPEAN RADIOLOGY EXPERIMENTAL, 2020, 4 (01)
[6]   Fast Deformable Image Registration for Real- Time Target Tracking During Radiation Therapy Using Cine MRI and Deep Learning [J].
Hunt, Brady ;
Gill, Gobind S. ;
Alexander, Daniel A. ;
Streeter, Samuel S. ;
Gladstone, David J. ;
Russo, Gregory A. ;
Zaki, Bassem I. ;
Pogue, Brian W. ;
Zhang, Rongxiao .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 115 (04) :983-993
[7]   Potential radiotherapy improvements with respiratory gating [J].
Keall P.J. ;
Kini V.R. ;
Vedam S.S. ;
Mohan R. .
Australasian Physics & Engineering Sciences in Medicine, 2002, 25 (1) :1-6
[8]   Fast free-form deformable registration via calculus of variations [J].
Lu, WG ;
Chen, ML ;
Olivera, GH ;
Ruchala, KJ ;
Mackie, TR .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (14) :3067-3087
[9]   The ViewRay System: Magnetic Resonance-Guided and Controlled Radiotherapy [J].
Mutic, Sasa ;
Dempsey, James F. .
SEMINARS IN RADIATION ONCOLOGY, 2014, 24 (03) :196-199
[10]  
Oktay O., 2018, 1 C MED IM DEEP LEAR