A Single-Ended Fault Location Method for Transmission Line Based on Full Waveform Features Extractions of Traveling Waves

被引:9
|
作者
Deng, Feng [1 ]
Zhong, Yihan [1 ]
Zeng, Zhe [1 ]
Zu, Yarui [2 ]
Zhang, Zhen [1 ]
Huang, Yifei [1 ]
Feng, Sixu [1 ]
Zeng, Xiangjun [3 ]
机构
[1] Changsha Univ Sci & Technol, Coll Elect & Informat Engn, Changsha 410076, Peoples R China
[2] State Grid Shijiazhuang Elect Power Co, Shijiazhuang 050304, Peoples R China
[3] Changsha Univ Sci & Technol, Sch Elect & Informat Engn, Hunan Prov Key Lab Smart Grids Operat & Control, Changsha 410076, Peoples R China
基金
中国国家自然科学基金; 湖南省自然科学基金;
关键词
Fault location; single end; traveling wave full waveform; convolution neural network; feature extraction; NETWORKS; TIME;
D O I
10.1109/TPWRD.2023.3248102
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Conventional single-ended traveling wave fault location methods, which commonly depend on partial features of traveling wavefronts, may lead to fault location failure, especially for weak-signal faults such as high impedance or zero-crossing faults and close-in faults. To tackle it, this article presents a fault location method according to the extracted panoramic features of traveling wave full waveform (TWFW) in time-frequency domains. Firstly, two rules of the TWFW features are probed, that is, the wavefront arrival sequence is varied from fault sections, as well as the frequency distribution of wavefronts is strongly related to the precise fault distance. Ergo, the mapping relationships between the TWFW and fault distance are qualitatively confirmed in order to demonstrate the uniqueness of the TWFW subsequently. Next, a LeNet-5-based convolution neural network (CNN) model is constructed to quantitatively evaluate such mapping relationships. In this model, various TWFW features will be extracted to the convolution channels when the CNN parameters are optimized adaptively, and the mapping relations can be formed in light of these sensitive features to estimate the fault distance. Finally, a Grad-CAM visualization method is deployed in the case study, and the accuracy along with the robustness of the proposed method in various fault conditions can be validated consequently.
引用
收藏
页码:2585 / 2595
页数:11
相关论文
共 50 条
  • [21] A Single-ended Fault Location Method Based on Distributed Parameter Model for Half-wavelength AC Transmission Line
    Wang, Li
    Shi, Xin
    Gong, Yun
    Hu, Yebin
    Li, Xu
    Deng, Maojun
    2018 2ND IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2018,
  • [22] Frequency domain approach to single-ended traveling wave fault location
    College of Electrical Engineering, Southwest Jiaotong University, Chengdu 610031, China
    Zhongguo Dianji Gongcheng Xuebao, 2008, 25 (99-104):
  • [23] Novel principle of single-ended line fault location technique for EHV transmission systems
    Ha, Heng-Xu
    Zhang, Bao-Hui
    Lu, Zhi-Lai
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2003, 23 (02): : 42 - 45
  • [24] A New Single-ended Fault Location Method Based on Bergeron Model
    Xin, Jianbo
    Lin, Xiangning
    Bo, Zhiqian
    MATERIALS SCIENCE AND INFORMATION TECHNOLOGY, PTS 1-8, 2012, 433-440 : 2939 - +
  • [25] Fault location for transmission line based on traveling waves using correlation analysis method
    Du Lin
    Pang Jun
    Sima Wenxia
    Tang Jun
    Zhou Jun
    ICHVE 2008: 2008 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION, 2008, : 681 - +
  • [26] A single-ended traveling-wave-based fault location for a hybrid transmission line using detected arrival times and TW′s polarity
    Rezaei, Davod
    Gholipour, Mehdi
    Parvaresh, Farzad
    ELECTRIC POWER SYSTEMS RESEARCH, 2022, 210
  • [27] A traveling wave natural frequency-based single-ended fault location method adaptive to system impedance
    Chen, Shuang
    Lin, Sheng
    Li, Xiaopeng
    He, Zhengyou
    Dianwang Jishu/Power System Technology, 2013, 37 (06): : 1739 - 1745
  • [28] Single-ended Protection Method of Flexible DC Line Based on Extremum Time of Fault Forward Traveling Wave
    Chen M.
    Jia K.
    Yao K.
    Liu X.
    Wen Z.
    Bi T.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2023, 43 (10): : 3742 - 3757
  • [29] Single-Ended Protection Method for UHVDC Transmission Line Based on Hilbert Energy Amplitude Information and Waveform Information
    Fan Y.
    Wang Y.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2021, 36 (09): : 1818 - 1830
  • [30] Fault Detection and Location of 35 kV Single-Ended Radial Distribution Network Based on Traveling Wave Detection Method
    Xu, Xiaowei
    Zhou, Fangrong
    Nie, Yongjie
    Xu, Wenhua
    Wang, Ke
    Ouyang, Jian
    Zhou, Kaihong
    Chen, Shan
    Han, Yiming
    PROCESSES, 2023, 11 (08)