Quantification of 25-hydroxyvitamin D2 and D3 in Mitra® devices with volumetric absorptive microsampling technology (VAMS®) by UHPLC-HRMS for regular vitamin D status monitoring

被引:6
作者
Tuma, Chiara [1 ,3 ]
Thomas, Andreas [1 ]
Braun, Hans [1 ,3 ]
Thevis, Mario [1 ,2 ]
机构
[1] German Sport Univ Cologne, Inst Biochem, Ctr Prevent Doping Res, Cologne, Germany
[2] European Monitoring Ctr Emerging Doping Agents, Cologne, Germany
[3] German Sport Univ Cologne, German Res Ctr Elite Sports momentum, Cologne, Germany
关键词
Orbitrap; 25(OH)D; Mass spectrometry; Validation; NIST; TANDEM MASS-SPECTROMETRY; DRIED BLOOD SPOTS; QUANTITATIVE-ANALYSIS; D METABOLITES; HEMATOCRIT; SAMPLES; BONE; BIAS;
D O I
10.1016/j.jpba.2023.115314
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The numbers of vitamin D inadequacies has reportedly increased in the general population, especially in the Northern hemisphere. However, routine measurement of 25(OH) vitamin D is usually associated with a sub-stantial effort due to the requirement of a venous blood sample taken by medical professionals. Thus, the objective of this work is to develop and validate an easy and minimal-invasive method, using a microsampling technique for autonomous blood collections by medically untrained individuals. The assay enables a simplified monitoring of the vitamin D-status in both, risk group and normal population throughout the year. For this purpose, a simple methanol extraction without derivatization combined with a UHPLC-HRMS method was developed to quantify 25(OH)D2 and 25(OH)D3 in capillary blood. For sample collection, a 20 mu l Mitra (R) device with VAMS (R) technology is used. By employing the six-fold deuterium- labelled 25(OH)D3 as internal standard, the validated assay provides accurate (<10%) and precise (<11%) results. With a LOQof 5 ng/ml, the approach also proved sensitive enough to adequately identify potential vitamin D deficiencies (< 12 ng/ml), and proof-of -concept analyses of authentic VAMS (R) samples (n = 20) yielded test results in the expected blood concentration range. Implementing VAMS (R) sampling for vitamin D-status monitoring enables a higher frequency due to a simplified, straightforward, and time-effective sample collection. VAMS (R) assures accurate sample volumes because of its absorptive capacities and, thus, area bias and homogeneity issues associated with conventional DBS are avoided. Regular monitoring of 25(OH)D status throughout the year supports people in high-risk groups for vitamin D-deficiency by early identifying inadequacies and, thus, preventing adverse health consequences.
引用
收藏
页数:8
相关论文
共 35 条
[31]   Self-sampling at home using volumetric absorptive microsampling: coupling analytical evaluation to volunteers' perception in the context of a large scale study [J].
Van Uytfanghe, Katleen ;
Heughebaert, Liesl ;
Stove, Christophe P. .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2021, 59 (05) :E185-E187
[32]   ANALYSIS OF VITAMIN D METABOLIC MARKERS BY MASS SPECTROMETRY: CURRENT TECHNIQUES, LIMITATIONS OF THE "GOLD STANDARD" METHOD, AND ANTICIPATED FUTURE DIRECTIONS [J].
Volmer, Dietrich A. ;
Mendes, Luana R. B. C. ;
Stokes, Caroline S. .
MASS SPECTROMETRY REVIEWS, 2015, 34 (01) :2-23
[33]   Where is the vitamin D receptor? [J].
Wang, Yongji ;
Zhu, Jinge ;
DeLuca, Hector F. .
ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 2012, 523 (01) :123-133
[34]   Vitamin D in health and disease: Current perspectives [J].
Zhang, Ran ;
Naughton, Declan P. .
NUTRITION JOURNAL, 2010, 9
[35]   The estimated benefits of vitamin D for Germany [J].
Zittermann, A. .
MOLECULAR NUTRITION & FOOD RESEARCH, 2010, 54 (08) :1164-1171