Quantification of 25-hydroxyvitamin D2 and D3 in Mitra® devices with volumetric absorptive microsampling technology (VAMS®) by UHPLC-HRMS for regular vitamin D status monitoring

被引:6
作者
Tuma, Chiara [1 ,3 ]
Thomas, Andreas [1 ]
Braun, Hans [1 ,3 ]
Thevis, Mario [1 ,2 ]
机构
[1] German Sport Univ Cologne, Inst Biochem, Ctr Prevent Doping Res, Cologne, Germany
[2] European Monitoring Ctr Emerging Doping Agents, Cologne, Germany
[3] German Sport Univ Cologne, German Res Ctr Elite Sports momentum, Cologne, Germany
关键词
Orbitrap; 25(OH)D; Mass spectrometry; Validation; NIST; TANDEM MASS-SPECTROMETRY; DRIED BLOOD SPOTS; QUANTITATIVE-ANALYSIS; D METABOLITES; HEMATOCRIT; SAMPLES; BONE; BIAS;
D O I
10.1016/j.jpba.2023.115314
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The numbers of vitamin D inadequacies has reportedly increased in the general population, especially in the Northern hemisphere. However, routine measurement of 25(OH) vitamin D is usually associated with a sub-stantial effort due to the requirement of a venous blood sample taken by medical professionals. Thus, the objective of this work is to develop and validate an easy and minimal-invasive method, using a microsampling technique for autonomous blood collections by medically untrained individuals. The assay enables a simplified monitoring of the vitamin D-status in both, risk group and normal population throughout the year. For this purpose, a simple methanol extraction without derivatization combined with a UHPLC-HRMS method was developed to quantify 25(OH)D2 and 25(OH)D3 in capillary blood. For sample collection, a 20 mu l Mitra (R) device with VAMS (R) technology is used. By employing the six-fold deuterium- labelled 25(OH)D3 as internal standard, the validated assay provides accurate (<10%) and precise (<11%) results. With a LOQof 5 ng/ml, the approach also proved sensitive enough to adequately identify potential vitamin D deficiencies (< 12 ng/ml), and proof-of -concept analyses of authentic VAMS (R) samples (n = 20) yielded test results in the expected blood concentration range. Implementing VAMS (R) sampling for vitamin D-status monitoring enables a higher frequency due to a simplified, straightforward, and time-effective sample collection. VAMS (R) assures accurate sample volumes because of its absorptive capacities and, thus, area bias and homogeneity issues associated with conventional DBS are avoided. Regular monitoring of 25(OH)D status throughout the year supports people in high-risk groups for vitamin D-deficiency by early identifying inadequacies and, thus, preventing adverse health consequences.
引用
收藏
页数:8
相关论文
共 35 条
[1]   Hematocrit and standardization in DBS analysis: A practical approach for hormones mainly present in the plasma fraction [J].
Ackermans, Mariette T. ;
de Kleijne, Vera ;
Martens, Frans ;
Heijboer, Annemieke C. .
CLINICA CHIMICA ACTA, 2021, 520 :179-185
[2]   Vitamin D deficiency 2.0: an update on the current status worldwide [J].
Amrein, Karin ;
Scherkl, Mario ;
Hoffmann, Magdalena ;
Neuwersch-Sommeregger, Stefan ;
Koestenberger, Markus ;
Berisha, Adelina Tmava ;
Martucci, Gennaro ;
Pilz, Stefan ;
Malle, Oliver .
EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2020, 74 (11) :1498-1513
[3]  
B.F.L, 2008, BUND ERN LEB NAT V 2
[4]   The relation between 25-hydroxyvitamin D with peak bone mineral density and body composition in healthy young adults [J].
Boot, Annemieke M. ;
Krenning, Eric P. ;
Keizer-Schrama, Sabine M. P. F. de Muinck .
JOURNAL OF PEDIATRIC ENDOCRINOLOGY & METABOLISM, 2011, 24 (5-6) :355-360
[5]   Analysis and quantification of vitamin D metabolites in serum by ultra-performance liquid chromatography coupled to tandem mass spectrometry and high-resolution mass spectrometry - a method comparison and validation [J].
Bruce, Stephen J. ;
Rochat, Bertrand ;
Beguin, Alexandre ;
Pesse, Benoit ;
Guessous, Idris ;
Boulat, Olivier ;
Henry, Hugues .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2013, 27 (01) :200-206
[6]   Variability in the analysis of 25-hydroxyvitamin D by liquid chromatography-tandem mass spectrometry: The devil is in the detail [J].
Couchman, Lewis ;
Benton, Christopher M. ;
Moniz, Cajetan F. .
CLINICA CHIMICA ACTA, 2012, 413 (15-16) :1239-1243
[7]   Does volumetric absorptive microsampling eliminate the hematocrit bias for caffeine and paraxanthine in dried blood samples? A comparative study [J].
De Kesel, Pieter M. M. ;
Lambert, Willy E. ;
Stove, Christophe P. .
ANALYTICA CHIMICA ACTA, 2015, 881 :65-73
[8]  
De Kesel PM, 2013, BIOANALYSIS, V5, P2023, DOI [10.4155/BIO.13.156, 10.4155/bio.13.156]
[9]   Volumetric Absorptive Microsampling: A Dried Sample Collection Technique for Quantitative Bioanalysis [J].
Denniff, Philip ;
Spooner, Neil .
ANALYTICAL CHEMISTRY, 2014, 86 (16) :8489-8495
[10]  
Denniff P, 2010, BIOANALYSIS, V2, P1385, DOI [10.4155/bio.10.103, 10.4155/BIO.10.103]