Clinical Results of Surgical Treatment for Comminuted Radial Head and Neck Fracture: Headless Compression Screws Versus Plate Fixation

被引:5
|
作者
Yano, Koichi [1 ]
Fukuda, Makoto [2 ]
Uemura, Takuya [3 ]
Kaneshiro, Yasunori [1 ]
Yamanaka, Kiyotaka [4 ]
Teraura, Hidetoshi [5 ]
Yamamoto, Ken [6 ]
Sasaki, Ryo [1 ]
Matsuura, Takeshi [1 ]
机构
[1] Seikeikai Hosp, Dept Orthopaed Surg, Sakai Ku, 1-1-1 Minamiyasuicho, Sakai, Osaka 5900064, Japan
[2] Baba Mem Hosp, Dept Orthopaed Surg, Nishi Ku, 4-244 Hamaderahunaocho, Sakai, Osaka 5928341, Japan
[3] Osaka Gen Hosp West Japan Railway Co, Dept Orthopaed Surg, Abeno Ku, 1-2-22 Matsuzakicho, Osaka 5450053, Japan
[4] Osaka City Gen Hosp, Dept Orthopaed Surg, Miyakojima Ku, 2-13-22 Miyakojimahondori, Osaka 5340021, Japan
[5] Higashisumiyoshi Morimoto Hosp, Dept Orthopaed Surg, Higashisumiyoshi Ku, 3-2-66 Takaai, Osaka 5460014, Japan
[6] Ishikiri Seiki Hosp, Dept Orthopaed Surg, 18-28 Yayoicho, Higashiosaka, Osaka 5798026, Japan
关键词
Radial head fracture; Radial neck fracture; Headless compression screw; Plate; Open reduction and internal fixation; Comminuted fracture; INTERNAL-FIXATION; PROXIMAL RADIUS; OPEN REDUCTION; ELBOW; ARTHROPLASTY;
D O I
10.1007/s43465-022-00792-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background We surgically treated comminuted radial head and neck fractures using headless compression screws, including multiple screws for the radial head and a single oblique screw for the radial neck. This study aimed to compare the clinical and radiological results for comminuted radial head and neck fractures between surgery using headless compression screws with a single oblique screw for the radial neck, our new procedure, and a plate system precontoured to the proximal radius. Methods This retrospective study included 23 patients (11 and 12 in the screw and plate groups, respectively). The fractures were type 3 according to the Mason-Johnston classification modified by Broberg and Morrey. Clinical outcomes analyzed included the motion range of the elbow and forearm, Mayo Elbow Performance Score, and radiological assessments. In addition, postoperative complications were also investigated. The average follow-up was 18 months. Results The bone union was achieved in all the patients, and there were no significant differences in clinical outcomes and radiological assessments except forearm supination (p = 0.02). Furthermore, additional surgical procedures were performed in one and five patients in the screw and plate groups, respectively (p = 0.16). Posterior nerve palsy was observed in two patients in the plate group. Complications were observed in one and six patients in the screw and plate groups, respectively (p = 0.07). Conclusion Both surgical procedures achieved good clinical and radiological outcomes with bone and ligament injury repair. The screw group had a greater range of forearm supination than the plate group.
引用
收藏
页码:253 / 261
页数:9
相关论文
共 50 条
  • [1] Clinical Results of Surgical Treatment for Comminuted Radial Head and Neck Fracture: Headless Compression Screws Versus Plate Fixation
    Koichi Yano
    Makoto Fukuda
    Takuya Uemura
    Yasunori Kaneshiro
    Kiyotaka Yamanaka
    Hidetoshi Teraura
    Ken Yamamoto
    Ryo Sasaki
    Takeshi Matsuura
    Indian Journal of Orthopaedics, 2023, 57 : 253 - 261
  • [2] A biomechanical study of headless compression screws versus a locking plate in radial head fracture fixation
    Rebgetz, Paul R.
    Daniele, Luca
    Underhill, Ian D.
    Ochsner, Andreas
    Taylor, Fraser J.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2019, 28 (04) : E111 - E116
  • [3] Radial Head Fracture Fixation Using Tripod Technique With Headless Compression Screws
    Lipman, Marc D.
    Gause, Trenton M.
    Teran, Victor A.
    Chhabra, A. Bobby
    Deal, D. Nicole
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2018, 43 (06): : 575.e1 - 575.e6
  • [4] Radial Head Fracture (Mason Type 4) Fixation With Headless Compression Screws: The "Tripod Technique"
    Phadatare, Jitesh P.
    Mankar, Sushil
    Harkare, Vismay V.
    Sakhare, Rahul H.
    Thakkar, Harsh B.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (08)
  • [5] Internal fixation with headless compression screws and back buttress plate for treatment of old Hoffa fracture
    Min Li
    Tu Chongqi
    Wang Guanglin
    Fang Yue
    Duan Hong
    Liu Lei
    Zhang Hui
    中华创伤杂志(英文版), 2014, 17 (02) : 79 - 83
  • [6] Internal fixation with headless compression screws and back buttress plate for treatment of old Hoffa fracture
    Li, Min
    Tu Chongqi
    Wang Guanglin
    Yue, Fang
    Hong, Duan
    Lei, Liu
    Hui, Zhang
    CHINESE JOURNAL OF TRAUMATOLOGY, 2014, 17 (02) : 79 - 83
  • [7] Prospective study of surgical fixation of radial head fractures using cannulated headless compression screws for simple and complex radial head fractures
    Wu, Pang Hung
    Dixit, Anushri
    Tan, David Meng Kiat
    Shen, Liang
    Chee, Yu Han
    JOURNAL OF ORTHOPAEDIC SURGERY, 2017, 25 (02) : 1 - 8
  • [8] Comparison of the fixation ability of headless compression screws and locking plate for metacarpal shaft transverse fracture
    Chiu, Yung-Cheng
    Hsu, Cheng-En
    Ho, Tsung-Yu
    Ting, Yen-Nien
    Wei, Bor-Han
    Tsai, Ming-Tzu
    Hsu, Jui-Ting
    MEDICINE, 2021, 100 (39) : E27375
  • [9] Ordinary Cannulated Compression Screws or Headless Cannulated Compression Screws? A Synthetic Bone Biomechanical Research in the Internal Fixation of Vertical Femoral Neck Fracture
    Zhang, Baokun
    Liu, Jingwen
    Zhang, Wei
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [10] Biomechanical Analysis of Conventional Partially Threaded Screws Versus Headless Compression Screws in Proximal Fifth Metatarsal (Jones) Fracture Fixation
    Lam, Kenrick
    Bui, Roger
    Morris, Randal
    Panchbhavi, Vinod
    FOOT & ANKLE SPECIALIST, 2021, 14 (06) : 509 - 514